Login:
Votes - 3, Average rating: 4.7 ( )

User manual Graco Inc., model Hydra Clean 308-523

Manafacture: Graco Inc.
File size: 636.96 kb
File name: a726c78e-9159-4f4f-a7ce-e14027f49c14.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


P.O. Box 1441 MINNEAPOLIS, MN 55440–1441 COPYRIGHT 1990, GRACO INC. 1535 2040 WARNING HIGH PRESSURE SPRAY CAN CAUSE SERIOUS INJURY. FOR PROFESSIONAL USE ONLY. OBSERVE ALL WARNINGS. Read and understand all instruction manuals before operating equipment. FLUID INJECTION HAZARD General Safety This pressure washer generates very high fluid pressure. Spray from the gun, leaks or ruptured components can inject fluid through your skin and into your body and cause extremely serious bodily injury including the need for amputation. Also, fluid injected or splashed into the eyes or on the skin can cause serious damage. NEVERpoint the spray gun or wand at anyone or at any part of the body. NEVER put hand or fingers over the spray tip. ALWAYS follow the Pressure Relief Procedure, beforecleaning or servicing any part of the sprayer. NEVER try to stop or deflect leaks with your hand or body. Be sure equipment safety devices are operating properly before each use. Medical Treatment If any fluid appears to penetrate your skin, get EMERGENCY MEDICAL TREATMENT AT ONCE. DO NOT TREAT AS A SIMPLE CUT. Tell the doctor exactly what fluid was injected. NOTE TO PHYSICIAN: Injection in the skin is a traumaticinjury.It is important to treat the injury surgically as soon as possible. Do not delay treatmentto research toxicity. Toxicity is a concern withsome exotic coatings injecteddirectly into the bloodstream. Consultation with a plastic surgeon orreconstructive hand surgeon may be advisable. Pressure Relief Procedure To reduce the risk of serious bodily injury, including fluid injection and splashing in the eyes or on the skin, always follow this procedure whenever you stop spraying for more than 10 minutes, when shutting down, and before checking or repairing any part of the system. 1. Engage the trigger safety latch. 2. Turn the sprayer off. 3. Remove the ignition cable from the spark plug. 4. Shut off the water supply. 5. Disengage the trigger safety latch and trigger the gun to relieve pressure, and then engage the trigger safety latch again. 6. Before long–term (overnight) storage or transporting of unit, disconnect the water supply and turn off the fuel supply valve. Spray Gun Safety Devices Be sure all gun safety devices are operating properly before each use. Do not remove or modify any part of the gun; this can cause a malfunction and result in serious bodily injury. SAFETY LATCH: Whenever you stop spraying for a moment, always set the gun safety latch in the engaged or “safe” position, making the gun inoperative. Failure to properly set the safety latch can result in accidental triggering of the gun. SPRAY TIP SAFETY: Use extreme caution when cleaning or changing spray tips. If a spray tip clogs while spraying, engage the gun safety latch immediately. ALWAYS follow the Pressure Relief Procedure and then remove the spray tip to clean it. . . EQUIPMENT MISUSE HAZARD EQUIPMENT MISUSE HAZARD General Safety Any misuse of the pressure washer or accessories, such as overpressurizing, modifying parts, using incompatible chemicals and fluids, or using worn or damaged parts, can cause them to rupture and result in fluid injection, splashing in the eyes or on the skin, or other serious bodily injury, fire, explosion or property damage. NEVERalter or modify any part of this equipment; doing so could cause it to malfunction. CHECK all spray equipment regularly and repair or replace worn or damaged parts immediately. ALWAYS wear protective eyewear and appropriate clothing. If using a chemical injector, read and follow the chemical manufacturer’s literature for recommendations on additional protective equipment, such as a respirator. System Pressure This sprayer can develop high operating pressures. Be sure that all spray equipment and accessories are rated to withstand the maximum working pressure of this sprayer. DO NOT exceed the maximum working pressure of any component or accessory used in the system. Chemical Compatibility BE SURE that all chemicals used in the chemical injector are compatible with the wetted parts of the hose, gun, wand and tip, as given in the Technical Data (inside back cover). Always read the chemical manufacturer’s literature before using any chemical in this pressure washer. HOSE SAFETY High pressure fluid in the hoses can be very dangerous. If the hose develops a leak, split or rupture due to any kind of wear, damage or misuse, the high pressure spray emitted from it can cause a fluid injection injury or other serious bodily injury or property damage. ALL FLUID HOSES MUST HAVE STRAIN RELIEFS ON BOTH ENDS. The strain reliefs help protect the hose from kinks or bends at or close to the coupling, which can result in hose rupture. TIGHTEN all fluid connections securely before each use. High pressure fluid can dislodge a loose coupling or allow high pressure spray to be emitted from the coupling. NEVERuse a damaged hose. Before each use, check entire hose for cuts, leaks, abrasion, bulging cover, or damage or move...

Other models in this manual:
Pressure Washers - Hydra Clean 800-670 (636.96 kb)
Pressure Washers - Hydra Clean 800-671 (636.96 kb)
Pressure Washers - Hydra Clean 800-672 (636.96 kb)
Pressure Washers - Hydra Clean 800-674 (636.96 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category