manual abstract


The supply hose should have a 3/4” inside diameter (ID) and be no longer than 50 feet. 2. The water supply pressure must be a minimum of 20 pounds per square inch (PSI) and a maximum of 125 PSI. The flow rate must be at least 3 gallons per minute (GPM). 3. Use a water softener if there is high mineral content in the water of your area. High mineral content causes excessive scale build-up in the coil/heat exchanger. 4. Un-roll the hose reel and then connect one end of the high pressure discharge hose to the water- gun assembly. ! Be sure all connections are securely tightened. Sudden release of high pressure streams can cause serious injury. OPERATING INSTRUCTIONS STARTING THE PRESSURE WASHER BEFORE STARTING THE PRESSURE WASHER 1. Read all safety instructions throughout this manual. 2. Be sure the motor switch is in the “OFF” position, red button pushed. 3. Ensure outlet is the proper voltage (120 volts). 4. Insert the male power plug into a grounded AC outlet. 5. Press and release the “RESET” button on the GFCI power cord. 6. Press “RESET” each time after plugging the GFCI power cord into a power source. COLD WATER OPERATION 1. After following all preparation instructions, turn the water supply on. 2. Turn the unit on by pushing the pump switch on the control panel. Once the unit starts, squeeze the trigger gun “ON” for 2 minutes to purge all air and mineral deposits from the system. This operation is to be done without lance terminal end. 3. Turn the pump switch to OFF position, release the trigger gun and lock in the “OFF” position. Fit the lance terminal end. To ensure you are in the high pressure mode, turn the nozzle holder to the right. 4. Your SCOUT 157596 is now ready to be used as a cold water pressure washer. Turn the unit “ON” by pushing the pump switch on the control panel. Squeeze the trigger-gun to spray a high pressure stream and release the trigger to stop the stream. 5. Every time you release tre trigger-gun, the machine automatically stops thanks to TOTAL STOP System. The machine will re-start automatically once you press again the trigger-gun. ! In case that TOTAL STOP is not working correctly, please note not allow the unit to operate in bypass mode (with trigger released in the “OFF” position) for more than 3 minutes. Premature failure of pump packing may occur if left in bypass mode for longer than 3 minutes. Never look directly into the nozzle unless it is disconnected from the spray wand. HOT WATER OPERATION 1. Fill fuel tank with 4,3 gallons of #l or #2 Diesel. 2. Be sure trigger gun is locked in the “OFF” position and remove the nozzle/wand assembly. 3. Turn the unit on by pushing the pump switch on the control panel. Once the unit starts, squeeze the trigger gun “ON” for 2 minutes to purge all air and mineral deposits from the system. 4. Turn the pump switch to “OFF” position, release the trigger gun and lock in the “OFF” position. Connect the nozzle-wand assembly to the gun assembly. To ensure you are in the high pressure mode, turn the nozzle to the right. 5. Turn the pump switch to “ON” position, turn the burner knob located on the control panel to “ON” (position 1) Squeeze the trigger gun to spray, burner only fires when the trigger is squeezed. 6. The unit is now ready to be used as a hot water pressure washer. Squeeze the trigger-gun to spray a high pressure stream, and release the trigger to stop the stream. 7. Cool down the heat exchanger by turning the burner knob “OFF” (0 position). Allow unit to run with trigger in the squeezed, “ON” position for at least 3 minutes. NOTE: On initial startup, water will begin turning hot in 30 seconds, reaching maximum temperature in 3 minutes with trigger squeezed. Burner stops firing when the trigger is released or when water exceeds the temperature setting. ! CAUTION! EXPOSED METAL EXHAUST OUTLET AND HOSE CONNECTIONS DURING HOT OPERATION ARE EXTREMELY HOT! STOPPING THE PRESSURE WASHER ! To protect your safety and the service of your SCOUT 157596, you must follow the procedure for stopping the pressure washer outlined below: 1. Run one gallon of clean water through the used detergent lines. (If detergent has been used during this operation run). 2. Turn burner switch to “OFF” (0 position). 3. Squeeze the trigger and discharge cool water for 3 minutes to cool the burner component. 4. Turn the unit “OFF” with the main switch on the control panel. 5. Turn off the water supply immediately. 6. Squeeze the trigger gun to relieve system pressure and drain excess water. 7. Disconnect power cord and unit hoses. USING THE DETERGENT INJECTOR This feature is designed for use with mild detergents. North Star detergents are highly recommended for use with all North Star pressure washers. 1. Prepare cleaning solution according to the detergent label directions. 2. Fill Detergent tank with detergent solution 3 Turn the nozzle at the end of the wand to the left for low pressure. 4. Start the unit as directed in the OPERATING INSTRUCTIONS. Brace yoursel...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category