Login:
Votes - 2, Average rating: 3.5 ( )

User manual Blue Rhino, model Outdoor LP Gas Barbecue Grill GBC730W-C

Manafacture: Blue Rhino
File size: 8.92 mb
File name: fde25fa0-9915-7b74-3182-952af40bf022.pdf
Language of manual:enfr
Free link for this manual available at the bottom of the page



manual abstract


Secure LP Gas Tank Secure tank by sliding tank retainer wire over shoulder of LP gas tank. Connect LP Gas Tank Before connecting, be sure that there is no debris caught in the head of the LP gas tank, head of the regulator valve or in the head of the burner and burner ports. Connect gas line to tank by turning knob clockwise until it stops. Disconnect LP Gas Tank Before disconnecting make sure the LP gas tank valve OFF. Disconnect gas line to tank by turning knob counterclockwise until it is loose. Need a tank of gas? Try tank exchange service. It’s easy, fast, safe, and available at tens of thousands of conveniently located retail outlets nationwide. You can purchase a new full tank or exchange your empty for a precision filled one. Operating Instructions Checking for Leaks Burner Connections Make sure the regulator valve and hose connections are securely fastened to the burner and the tank. If your unit was assembled for you, visually check the connection between the burner pipe and orifice. Make sure the burner pipe fits over the orifice. WARNINGFOR YOUR SAFETY: Failure to inspect this connection or follow these instructions could cause a fire or an explosion which can cause death, serious bodily injury, or damage to property. Please refer to diagram for proper installation. If the burner pipe does not rest flush to the orifice, please contact 1.800.762.1142 for assistance. Tank/Gas Line Connection Make 2-3 oz.a of leak solution by mixing one part liquid dishwashing soap with three parts water. Make sure control knobs are off. Turn LP gas tank ON at valve. Spoon leak check solution at all “x” locations If any bubbles appear turn LP gas tank OFF, reconnect and re-test. If you continue to see bubbles after several attempts, disconnect LP gas source and contact 1.800.762.1142 for assistance. If no bubbles appear after one minute turn tank OFF, wipe away solution and proceed. Operating Main Burners Lighting 1. Open lid. Attempting to light the burner with the lid closed may cause an explosion! 2. Make sure there are no obstructions of airflow to the gas unit. Spiders and insects can nest within and clog the burner / venturi tube at the orifice. A clogged burner tube can lead to a fire beneath the appliance. 3. All control knobs must be in the OFF position. 4. Turn on gas at LP gas tank. 5. Push and turn control knob c ounterclockwise to HIGH. 6. Press the electronic igniter button and hold for 5 seconds to light burner. 7. If ignition does not occur in 5 seconds, turn burner control knob OFF, wait 5 minutes, and repeat lighting procedure. 8. If igniter does not light burner, use a lit match secured with the lighting rod provided to light burners manually. Access the burners through the cooking grid and heat plates. Position the lit match near side of the burner. Important: Always use the lighting rod provided when lighting burners with a match. 9. After lighting, observe the burner flame, make sure all burner ports are lit and flame height matches illustration. CautionIf burner flame goes out during operation, immediately turn the gas “OFF” and open lid to let the gas clear for about 5 minutes before re-lighting. LP Gas Connection Burner venturi LP Gas Valve with Orifice Main Burners LP Gas Connection LP Gas Valve with Orifice Burner venturi Side Burner XXXXX LP Gas Tank Valve Control Knob Main Burner Lighting Rod Insert Main Burner Lighting Rod Placement Slight Yellow Flame Slight Blue Burner Dark Blue Main burner proper flame height. 3. Keep the ventilation opening(s) of the LP gas tank area free and clear from debris. 4. Visually check the burner flames, to make sure your grill is working properly. 5. See cleaning instructions below for proper cleaning instructions. 6. Check and clean the burner/venturi tubes for insects and insect nests. A clogged tube can lead to a fire beneath the grill. Cleaning Surfaces 1. Wipe surfaces clean with mild dishwashing detergent or baking soda. 2. For stubborn surfaces use a citrus based degreaser and a nylon scrubbing brush. 3. Rinse clean with water. Cleaning Main Burner 1. Turn gas off at the control knobs and LP gas tank. 2. Remove cooking grid and heat plates. 3. Remove burner by removing the fasteners securing the burner to the grill bottom. 4. Lift burner up and away from gas valve orifice. 5. Disconnect wire from spark electrode. 6. Clean inlet (venturi) of burner with small bottle brush or compressed air. 7. Remove all food residue and dirt on burner surface. 8. Clean any clogged ports with a stiff wire (such as an opened paper clip) 9. Inspect burner for any damage (cracks or holes). If damage is found, replace with new burner. 10. Reinstall burner, check to insure that gas valve orifice is correctly positioned inside burner inlet (venturi). Also check position of spark electrode. 11. Replace heat plate and cooking grid. 12. Preform leak test. Cleaning Side Burner 1. Turn gas off at the control knobs and LP gas tank. 2. Remove side burner grid. 3. Remove burner ...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category