Login:
Votes - 3, Average rating: 3.3 ( )

User manual Motion Computing, model C5

Manafacture: Motion Computing
File size: 1.62 mb
File name: 42eedc4a-2209-4a41-98ee-1eda5ef4ff78.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


• Avoid exposing the display to direct sunlight for long periods of time. View Anywhere display • Clean fingerprints and most marks from the display surface by wiping it with the soft cloth (provided). Do not spray or pour liquids directly onto the display surface itself. Do not use an abrasive cleaner on the display. If liquid is spilled on the display, wipe it up immediately. For more information, see “Cleaning in a health care environment” on page 49. • If needed, clean with any alcohol-based product recommended for anti-reflective glass. Other cleaning products might leave a residue. • Avoid using tissues or paper towels to clean the display surface. These contain wood fibers that can scratch the display. • Use only the C5 pen on the display. Do not write on the display with an ink pen or pencil, or any other object that could damage the display. • Protect the display surface from unnecessary contact by using a case when transporting the C5. • Avoid exposing the display to direct sunlight for long periods of time. Chapter 4 Care and Maintenance Cleaning in a health care environment This section describes the cleaning procedures for the Motion C5 in a health care environment. Disinfecting procedures You should periodically disinfect the C5 according to the institutional polices of surface and equipment safety and cleanliness. Motion has tested a variety of antimicrobial solvents and information on specific products is available upon request. According to the Centers for Disease Control and Prevention, “items that do not ordinarily touch the patient or touch only intact skin are not involved in disease transmission, and generally do not necessitate disinfection between uses on different patients”.1 We recommend using an EPA-approved low-level disinfectant when general cleaning is required. For a list of cleaning solutions tested by Motion Computing, see “Cleaning solutions” on page 50. If the C5 becomes soiled with blood or other body fluids, a hospital-approved low-level disinfectant that is tuberculocidal/virucidal when used at recommended dilutions and contact times can be used. Visibly soiled areas should first be cleaned and then disinfected, or a detergent disinfectant can be used. For disinfection, the cleaned areas should be moistened with the appropriate germicide and allowed to air dry.2 If the C5 is used with patients who are infected or colonized with vancomycin-resistant enterococci or other drug-resistant microorganisms judged by the infection control program (based on current state, regional, or national recommendations, to be of special or clinical or epidemiologic significance or with highly virulent microorganisms such as Ebola or Lassa), then the unit should be dedicated to one patient or patient cohort or subjected to low-level cleaning between patient uses.1 1. Centers for Disease Control and Prevention. “Sterilization or Disinfection of Medical Devices-General Principles.” 2002. <(20 Sept. 2006). 2. Centers for Disease Control and Prevention. “Sterilization or Disinfection of Patient-Care Equipment-HIV Related.” 2000. <(20 Sept. 2006). Chapter 4 Care and Maintenance 50 Chapter 4 Care and Maintenance Training and documentation considerations All users of portable computers in the health care environment should be provided with training on proper cleaning procedures. Cleaning procedures should be added to the institution's policies and procedures for infection prevention. Cleaning solutions This section describes various cleaning solutions that have been tested by Motion Computing. Review the manufacturer's guidelines for proper use of the product. Cleaning the fan cover If the fan cover becomes soiled, it can be removed and cleaned. To clean the fan cover 1. Shut down the C5, unplug it, and remove the battery. 2. Turn the unit over so that the back side is facing up. 3. Press the fan cover release button. 4. Slide the fan cover away from the unit to remove it. 5. Clean the fan cover according to the guidelines for your organization. 6. After the fan cover is clean and dry, slide it back onto the C5 until it snaps into place. Product Type Manufacturer Comments Vira-Guard Veridien Concentrated Isopropanol. Does not leave film. Cavi-Wipes Metrex Isopropanol and Ethylene Glycol Monobutyl Ether. Leaves a slight film which needs a secondary wipe with dry cloth to remove. Sani-Cloth PDI Quaternary Ammonium. Leaves a slight film which needs a secondary wipe with dry cloth to remove. Press Cleaning the fingerprint reader Under normal circumstances, you should clean the fingerprint reader once a month, or whenever necessary. To clean the fingerprint reader 1. Shut down the C5, unplug it, and remove the battery. 2. Lightly spray a cotton swab with household window cleaner. 3. Gently rub the sensor surface with the cotton swab, slowly rotating the swab so a new, clean surface of t...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category