manual abstract
NOTE: Loosely tighten the screws for further adjustment. B A C D Fig. 9 11 3. Locate the 1/4-20x2." hex head screw (G) Fig. 10. Place the 1/4" internal tooth lockwasher (O) M6.4 flat washer (P) and the 1/4" external tooth lockwasher (R) on the screw (G). 4. Position the recessed end (E) Fig. 11 of the splitter bracket (B) against the end of the pivot rod (F), and fasten using the assembly in STEP 3. NOTE: Loosely tighten the hardware for further adjustment. 5. Position the splitter (H) Fig. 13 against the splitter support bracket, making certain the two protrusions (K) on the splitter support bracket are inside the slot of splitter (H). R P O G F E B Fig. 10 Fig. 11 G K H Fig. 12 Fig. 13 6. Attach the splitter (H) Fig. 14 to the splitter support bracket (B). Place a 1/4" external tooth lockwasher and an M6.4 flat washer on an M6x1x20mm hex head screw (L). 7. Insert the screw (L) Fig. 14 through the splitter support bracket (C) and the splitter (H). Place an M6.4 flat washer and a 1/4" external tooth lock washer on the screw (L). Thread an M6x1 wing nut L (M) Fig. 15 on the screw (L) Fig. 15. H B Fig. 14 12 H R C G 8. Use a straight edge to see if the splitter (H) Fig. 16 is aligned with the saw blade (R). If an adjustment is necessary, the splitter (H) can be moved left or right and rotated. 9. When the splitter is properly aligned with the saw blade, tighten the screws (C) and (G) Fig. 17. Fig. 15 KMN P H H R C G Fig. 16 Fig. 17 MITER GAUGE The miter gauge is shipped assembled and is supplied with a T-slot bar (A) Fig. 18 that is inserted into either one of the two T-slotted miter gauge grooves (B) located in the table top. The T-slot prevents the miter gauge from falling when it is extended beyond the front of the table when cross-cutting extra wide workpieces. A B Fig. 18 ATTACHING MITER GAUGE HOLDER DISCONNECT MACHINE FROM POWER SOURCE. E A B GF Fig. 19 Fig. 20 13 1. Attach the spring clip (E) Fig. 19 to the miter gauge holder (A) using an M4x.7x10mm pan head screw (F), 3/16" external tooth lockwasher, (B) and M4x.7 hex nut. NOTE: The hex nut (G) Fig. 20 will fit into the recess at the back of the miter gauge holder (A) Fig. 19 to keep the spring clip (E) secured to the miter gauge holder. 2. Attach the miter gauge holder (A) Fig. 21 to the left side of the saw cabinet using the four M4x.2x10mm screws (B) Fig. 22, and 3/16" flat washers (C) from inside of the saw cabinet. 3. Fig. 23 illustrates the miter gauge (D) inserted into the holder. Fig. 21 Fig. 22 A B C D Fig. 23 Fig. 24 B A D C ASSEMBLING RIP FENCE 1. Thread the M8x1.25 hex nut (A) Fig. 24, approximately halfway on the stud of the handle (B). 2. Thread the handle (B) Fig. 24 into the tapped hole (C) in the fence cam (D). Tighten the hex nut (A) Fig. 25 against the cam (D). 3. The rip fence is usually set up on the right hand side of the saw table. Lift the lock handle (B) Fig. 26 and position the fence on the table. Push down on the handle (B) Fig. 26 to lock the fence in place. D B A Fig. 25 Fig. 26 14 OPERATION OPERATIONAL CONTROLS AND ADJUSTMENTS OPERATIONAL CONTROLS AND ADJUSTMENTS STARTING AND STOPPING SAW The on/off switch (A) Fig. 27 is located on the front of the saw cabinet. To turn the saw “ON”, move the switch (A) up to the “ON” position. To turn the saw “OFF”, move the switch (A) down to the “OFF” position. MAKE SURE THAT THE SWITCH IS IN THE “OFF” POSITION BEFORE PLUGGING IN THE POWER CORD. IN THE EVENT OF A POWER FAILURE, MOVE THE SWITCH TO THE “OFF” POSITION. AN ACCIDENTAL START-UP CAN CAUSE INJURY. LOCKING SWITCH IN THE “OFF” POSITION IMPORTANT: When the tool is not in use, the switch should be locked in the “OFF” position to prevent unauthorized use. To lock the tool, grasp the switch toggle (B) and pull it out of the switch (Fig. 28). With the switch toggle (B) removed, the switch will not operate. However, should the switch toggle be removed while the saw is running, the machine can be turned “OFF,” but cannot be restarted without re-inserting the switch toggle (B). Fig. 28Fig. 27 A B C OVERLOAD PROTECTION Your saw is equipped with a reset button (C) Fig. 28. If the motor stops or fails to start due to over-loading (cutting stock too fast, using a dull blade, using the saw beyond its capacity, etc.) or low voltage, turn the switch to the “OFF” position. Let the motor cool three to five minutes. Push the reset button (C) to reset the overload device. The motor can then be started again in the usual manner. BLADE HEIGHT ADJUSTMENT To adjust the height of the saw blade, turn the handwheel (A) Fig. 29. Turning the handwheel clockwise lowers the blade and turning the handwheel counterclockwise raises the blade. A Fig. 29 15 To tilt the saw blade, loosen the lock handle (A) Fig. 30 and move the handwheel (B) until the blade is at the desired angle. Tighten the lock handle (A). NOTE: The lock handle (A) is spring-loaded. Pull out on the handle (A) and reposition it on the serrated stud located underneath the handle. THE BLADE TILTIN...
Other models in this manual:Saws - TS200 (2.42 mb)