For example, if the room doesn't get too warm it will stay at the slowest speed. If the room temperature rises quickly, such as a door being opened, it will automatically go to the highest speed. The fan speeds will readjust back to the slowest speed as the room returns to the original set temperature. Press either the Fan Slower or Fan Faster button to m adjust the fan speed manually. YOU WILL SEE: LIGHT On _Note: Use this function only when cooling is not desired, such as for room air circulation or to exhaust stale air. You can choose any fan speed you prefer. During this function, the display will show the actual room temperature, not the set temperature as in the cooling mode. YOU WILL SEE: On Note: In this mode, the fan will continue to run for 3 minutes after the compressor shuts off. The fan then cycles on for 2 minutes at 10 minute intervals until the room temperature is above the set temperature, at which time the unit turns back on. _i®_ii i_!_ii. Air Conditioner (continued) Features TIMER: DELAY FEATURE STOP / START DO THIS: PRESS TIMER BU]q-ON ® SLEEP FEATURE: {N |) DO THIS: PRESS SLEEP BUTTON YOU WILL SEE: TIMER SETTING LIGHT On Note: For Delay Stop, the unit must be in the On position. Note: For Delay Start, the unit must be in the Off position. To adjust timer setting, tap or hold the UP arrow(A) DOWN arrow(v) to change delay timer at .5 hour increment, up to 10 hours, then at 1 hour increments up to 24 hours. The control will count down the time remaining until start (8, 7.5, 7, etc.). The Delay Start mode automatically selects cooling with maximum Fan Speed. The temperature maintained will be the same as previously ® :::::0::::: set. To change the set temperature, press "COOL" then Up or Down arrows until the desired temperature is indicated on the display. After 5 seconds, the control will automatically change the display back to the hours remaining until the unit will start/stop. Turning the unit "ON" or "OFF" at any time will cancel the Delay Start/Stop function. YOU WILL SEE: LIGHT On @ In this "MODE" the selected temperature will increase by 2 degrees F 30 minutes after the mode is selected. The temperature will then increase by another 2 degrees F after an additional 30 minutes. This new temperature will be maintained for 7 hours before it returns to the originally selected temperature. This ends the "Sleep" MODE and the unit will continue to operate as originally programmed. The "Sleep" MODE program can be cancelled at any time during operation by pressing "Sleep" MODE button. Air Conditioner Features (continued) CHECK FILTER FEATURE: YOU WILL SEE: @ /% @ /% Note: This feature is a reminder to clean the Air Filter (See Care and Cleaning) for more efficient operation and cooling. The LED (light) will illuminate after 250 hours of operation. To reset after cleaning the filter, press the "Check Filter" button and the light will go off. TO TURN UNIT OFF: DO THIS: PRESSON/OFF BUTTON ADDiTiONAL THINGS YOU SHOULD KNOW Now that you have mastered the operating procedure, here are more features in your control that you should become familiar with. * The "Cool" circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly. This prevents overheating of the compressor and possible circuit breaker tripping. The fan will continue to run during this time. * The control will maintain the set temperature within 2 degrees Fahrenheit, between 60F and 90F degrees. * The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius. To convert from one to the other and back, press and hold the 'q-EMP/TIMER "Up (/'-_) and Down (v) buttons together for 3 seconds. Fresh Air Vent Control (On some models) The Fresh Air Vent allows the air conditioner to: 1. Redrculate inside air Vent Closed (see Fig. 1) 2. Draw fresh air into the roo_ Vent Open (see Fig. 2) 3. Exchange air from the room and draws fresh air into the room Vent and Exhaust Open (see Fig. 3) Figure I (VENT CLOSED) Figure 2 (VENT OPEN) Air Conditioner Features (8-WAY) Figure 3 (VENT & EXHAUST OPEN) Air Directional Louvers Air directional louvers control air flow direction. Your air conditioner has the louver type described below. Auger Type The louvers will allow you to direct the air flow Up or Down and Left or Right throughout the room as needed. Rotate the Auger Wheel until the desired direction is obtained. AUGER WHEELS Care and Cleaning Clean your air conditioner occasionally to keep it looking new. Be sure to unplug the unit before cleaning to prevent shock or fire hazards. Air Filter Cleaning The air filter should be checked at least once a month to see if cleaning is necessary. Trapped particles in the filter can build up and cause an accumulation of frost on the cooling coils. • Push the vent handle to the Vent Closed position (where applicable). • Open the front panel. • Grasp the filter by the center and pull up and out. • Wash the filter using liquid dishwashing detergent and warm...