|
manual abstract
1 FEATURES AND FUNCTIONS .............................. 2 NAME OF PARTS ................................................... 3 PREPARATION ....................................................... 5 OPERATION ........................................................... 6 TIMER OPERATION ............................................... 8 SLEEP TIMER OPERATION ................................... 9 MANUAL AUTO OPERATION ............................... 9 ADJUSTING THE DIRECTION OF AIR CIRCULATION ............................................... 10 SWING OPERATION ............................................ 11 CLEANING AND CARE ........................................ 12 SELECTING THE REMOTE CONTROL UNIT SIGNAL CODE ..................................................... 13 TROUBLESHOOTING .......................................... 14 OPERATING TIPS ................................................ 15 SAFETY PRECAUTIONS . Before using the appliance, read these “PRECAUTIONS” thoroughly and operate in the correct way. . The instructions in this section all relate to safety; be sure to maintain safe operating conditions. . “DANGER”, “WARNING” and “CAUTION” have the following meanings in these instructions: DANGER! This mark indicates procedures which, if improperly performed, are most likely to result in the death of or serious injury to the user or service personnel. WARNING! This mark indicates procedures which, if improperly performed, might lead to the death or serious injury of the user. CAUTION! This mark indicates procedures which, if improperly performed, might possibly result in personal harm to the user, or damage to property. DANGER! CAUTION! . Do not attempt to install this air conditioner by yourself. . This unit contains no user-serviceable parts. Always consult authorized service personnel for repairs. . When moving, consult authorized service personnel for disconnection and installation of the unit. . Do not become over-exposed to cold air by staying in the direct path of the airflow of the air conditioner for extended periods of time. . Do not insert fingers or objects into the outlet port or intake grilles. . Do not start and stop air conditioner operation by disconnecting the power supply cord and so on. . Take care not to damage the power supply cord. . In the event of a malfunction (burning smell, etc.), immediately stop operation, turn off the electrical breaker, and consult authorized service personnel. . Provide occasional ventilation during use. . Do not direct air flow at fireplaces or heating apparatus. . Do not climb on, or place objects on, the air conditioner. . Do not hang objects from the indoor unit. . Do not set flower vases or water containers on top of air conditioners. . Do not expose the air conditioner directly to water. . Do not operate the air conditioner with wet hands. . Do not pull power supply cord. . Turn off power source when not using the unit for extended periods. . Check the condition of the installation stand for damage. . Do not place animals or plants in the direct path of the air flow. . Do not drink the water drained from the air conditioner. . Do not use in applications involving the storage of foods, plants or animals, precision equipment, or art works. . Do not apply any heavy pressure to radiator fins. . Operate only with air filters installed. . Do not block or cover the intake grille and outlet port. . Ensure that any electronic equipment is at least one metre away from either the indoor or outdoor units. . Avoid installing the air conditioner near a fireplace or other heating apparatus. . When installing the indoor and outdoor units, take precautions to prevent access by infants. . Do not use inflammable gases near the air conditioner. En-1 FEATURES AND FUNCTIONS AUTOMATIC OPERATION . COOLING MODEL Merely press the START/STOP button, and the unit will begin automatic operation in the Cooling or Dry mode as appropriate, in accordance with the thermostat setting and the actual temperature of the room. . HEAT & COOL MODEL (REVERSE CYCLE) Merely press the START/STOP button, and the unit will begin automatic operation in either the Heating, Cooling or Monitor modes as appropriate, in accordance with the thermostat setting and the actual temperature of the room. SLEEP TIMER . COOLING MODEL When the SLEEP timer button is pressed during Cooling or Dry mode, the thermostat setting is gradually rised during the period of operation. When the set time is reached, the unit automatically turns off. . HEAT & COOL MODEL (REVERSE CYCLE) When the SLEEP timer button is pressed during Heating mode, the air conditioner’s thermostat setting is gradually lowered during the period of operation; during Cooling or Dry mode, the thermostat setting is gradually rised during the period of operation. When the set time is reached, the unit automatically turns off. WIRELESS REMOTE CONTROL UNIT The WIRELESS REMOTE CONTROL UNIT allows convenient control of air conditioner operation. OMNI-DIRECTI...
Other models in this manual:Air Conditioner & Split Systems - HALCYON P/N9359944058 (425.18 kb)