Login:
Votes - 4, Average rating: 3.5 ( )

User manual Minolta, model W091CA TSG0

Manafacture: Minolta
File size: 2.09 mb
File name: LG_W242CA_ENG.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



Other manuals for this model:

manual abstract


Dealer's Name Date Purchased Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues. READ THIS MANUAL Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of Troubleshooting Tips first, you may not need to call for service at all. PRECAUTION • Contact the authorized service technician for repair or maintenance of this unit. • Contact the installer for installation of this unit. • The air conditioner is not intended for use by young children or invalids without supervision. • Young children should be supervised to ensure that they do not play with the air conditioner. • When the power cord is to be replaced, replacement work shall be performed by authorized personnel only using only genuine replacement parts. • Installation work must be performed in accordance with the National Electric Code by qualified and authorized personnel only. 1. Safety Precautions 2. Operating Instructions 3. Care and Maintenance 4. Hardware Installation 5. Common Issues Precautions Safety Precautions 3 ENGLISH To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. WARNING CAUTION This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to properties only. Meanings of symbols used in this manual are as shown below. Be sure not to do. Be sure to follow the instruction. WARNING Installation Always install the expansion panel(s). • No installation may cause fire and electric shock accident. Do not place the power cord near a heater. • It may cause fire and electric shock. Do not use the power cord near flammable gas or combustibles such as gasoline, benzene, thinner, etc. • It may cause explosion or fire. Do not disassemble or modify products. • It may cause failure and electric shock. Gasolin 4 Operation Plug in the power plug properly. • Otherwise, it will cause electric shock or fire due to heat generation or electric shock. Do not operate or stop the unit by inserting or pulling out the power plug. • It will cause electric shock or fire due to heat generation. Do not damage or use an unspecified power cord. • It will cause electric shock or fire. Do not modify power cord length. • It will cause electric shock or fire due to heat generation. Do not share the outlet with other appliances. • It will cause electric shock or fire due to heat generation. Always plug into a grounded outlet. • No grounding may cause electric shock (See Installation Manual). Unplug the unit if strange sounds, odors, or smoke come from it. • Otherwise it may cause fire and electric shock accident. Do not use the socket if it is loose or damaged. • It may cause fire and electric shock. Do not operate with wet hands or in damp environment. • It will cause electric shock. ON 8 OPERATION High Cool ( ), Med Cool ( ) and Low Cool ( ) provide cooling with different fan speeds. Med Fan ( ) or Low Fan ( ) provides air circulation and filtering without cooling. Off ( ) turns the air conditioner off. : If you move the switch from a cool setting to off or to a fan setting, wait at least 3 minutes before switching back to a cool setting. Cooling Descriptions For Normal Cooling- Select High Cool or Med Cool with the Operation knob at the midpoint of Thermostat knob. For Maximum Cooling- Select High Cool with the Operation knob at the highest number available on your Thermostat knob. For Quieter & Nighttime Cooling- Select Low Cool with the Operation knob at the midpoint of Thermostat knob. THERMOSTAT The THERMOSTAT is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number(the right side) and the indoor air will become cooler. The 5 or 6 position (the middle position of arc) is a normal setting for average conditions. AUTO SWING (Optional) Auto swing switch controls the horizontal air direction by air swing system (not on all models). ON ( ) : Auto swing is operated. OFF ( ) : Auto swing is not operated. CAUTION: When the air conditioner has been performed its cooling operation and is turned off or set to the fan position, wait at least 3 minutes before resetting to the cooling operation again. NOTICE o Thermostat Operation FAN FAN Thermostat Warmer Cooler Heater Operation NOTICE : Optional 9 ENGLISH Controls AUTO SWING (Optional) ON ( ) : Air swing is operated while OPERATION knob is set to the COOL or HEAT position. OFF( ) : Stops the operation of air swing. THERMOSTAT Turn th...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category