User manual York, model D2EB030

Manafacture: York
File size: 746.44 kb
File name: aa72b8d2-54f8-4023-b9ff-c3f31f695f62.pdf

Language of manual:en

The document is loading, please wait
The document is loading, please wait

manual abstract


MULTIPLIER 240 208 .75 230 .92 480 460 .92 600 575 .92 ELECTRIC HEAT CORRECTION FACTORS TABLE 11: ELECTRICAL DATA (COOLING / ELECTRIC HEAT) MODEL DEB POWER SUPPLY COMPRESSOR COND. FAN MOTORS SUPPLY AIR BLOWER MOTOR ELECTRIC HEAT ACCESSORY MCA (AMPS) MAX FUSE/ SIZE1 (AMPS) MAX HACR2 BREAKER SIZE RLA LRA FLA FLA MODEL NO. STAGE KW TOTAL AMPS 030 208/230-1-60 12.0 73.0 1.1 2.6 2NH04500506 1 3.8/5.0* 18.1/20.8 25.8/29.3 30/30 30/30 2NH04500706 2 5.6/7.5* 27.3/31.3 37.1/42.3 40/45 40/45 2NH04501006 2 7.5/10.0* 36.1/41.7 48.4/55.3 50/60 50/60 2NH04501506 2 11.3/15.0* 54.2/62.5 71.0/81.4 80/90 80/90 036 208/230-1-60 17.3 94.0 1.1 3.5 2NH04501006 2 7.5/10.0* 36.1/41.7 49.5/56.5 50/60 50/60 2NH04501506 2 11.3/15.0* 54.2/62.5 72.1/82.5 80/90 80/90 042 208/230-1-60 15.5 86.0 1.1 3.5 2NH04500506 1 3.8/5.0* 18.1/20.8 26.9/30.4 35/35 35/35 2NH04500706 2 5.6/7.5* 27.1/31.3 38.2/43.4 40/45 40/45 2NH04501006 2 7.5/10.0* 36.1/41.7 49.5/56.5 50/60 50/60 2NH04501506 2 11.3/15.0* 54.2/62.5 72.1/82.5 80/90 80/90 048 208/230-1-60 24.4 140.0 1.3 4.0 2NH04501006 2 7.5/10.0* 36.1/41.7 50.1/57.1 60/60 60/60 2NH04501506 2 11.3/15.0* 54.2/62.5 72.1/83.1 80/90 80/90 2NH04502006 2 15.0/20.0* 72.2/83.3 95.3/109.2 100/110 100/110 2NH04502506 2 18.8/25.0* 90.3/104.2 117.8/135.2 125/150 125/150 060 208/230-1-60 38.0 165.0 1.3 7.0 2NH04501006 2 7.5/10.0* 36.1/41.7 53.9/60.8 70/70 70/70 2NH04501506 2 11.3/15.0* 54.2/62.5 76.5/86.9 80/90 80/90 2NH04502006 2 15.0/20.0* 72.2/83.3 99.0/112.9 100/125 100/125 2NH04502506 2 18.8/25.0* 90.3/104.2 121.6/139.0 125/150 125/150 036 208/230-3-60 10.9 78.0 1.1 3.5 2NH04501025 1 7.5/10.0* 20.8/24.1 30.4/34.4 35/35 35/35 2NH04501525 1 11.3/15.0* 31.3/36.1 43.5/49.5 45/50 45/50 12 Johnson Controls Unitary Products 36Q1Q1 -XT G-B-Q5Q8 TABLE 11: ELECTRICAL DATA (COOLING / ELECTRIC HEAT) (CONTINUED) MODEL DEB POWER SUPPLY COMPRESSOR COND. FAN MOTORS SUPPLY AIR BLOWER MOTOR ELECTRIC HEAT ACCESSORY MCA (AMPS) MAX FUSE/ SIZE1 (AMPS) MAX HACR2 BREAKER SIZE RLA LRA FLA FLA MODEL NO. STAGE KW TOTAL AMPS 042 208/230-3-60 11.5 88.0 1.1 3.5 2NH04501025 1 7.5/10.0* 20.8/24.1 30.4/34.4 35/35 35/35 2NH04501525 1 11.3/15.0* 31.3/36.1 43.5/49.5 45/50 45/50 048 208/230-3-60 14.1 105.0 0.7 4.0 2NP04501025 1 7.5/10.0* 20.8/24.1 31.1/35/1 35/40 35/40 2NP04501525 1 11.3/15.0* 31.3/36.1 44.1/50.1 45/60 45/60 2NP04502025 2 15.0/20.0* 41.7/48.1 57.1/65.1 60/70 60/70 2NH04502525 2 18.8/25.0* 52.1/60.1 70.2/80.2 80/90 80/90 060 208/230-3-60 16.0 125.0 1.3 7.0 2NH04501025 1 7.5/10.0* 20.8/24.1 34.8/38.8 40/40 40/40 2NH04501525 1 11.3/15.0* 31.3/36.1 47.8/53.9 50/60 50/60 2NH04502025 2 15.0/20.0* 41.7/48.1 60.9/68.9 70/70 70/70 2NH04502525 2 18.8/25.0* 52.1/60.1 73.9/83.9 80/90 80/90 036 460-3-60 5.8 40.0 0.6 1.8 2NH04501046 1 10.0** 12 17.3 20 20 2NH04501546 1 15.0** 18 24.8 25 25 042 460-3-60 5.8 42.0 0.6 1.8 2NH04501046 1 10.0** 12 17.3 20 20 2NH04501546 1 15.0** 18 24.8 25 25 048 460-3-60 7.1 55.0 0.8 2.0 2NP04501046 1 10.0** 12 17.5 20 20 2NH04501546 1 15.0** 18 25.1 30 30 2NH04502046 2 20.0** 24.1 32.6 35 35 2NH04502546 2 25.0** 30.1 40.1 45 45 060 460-3-60 8.0 67.0 0.7 3.5 2NH04501046 1 10.0** 12 19.4 20 20 2NH04501546 1 15.0** 18 26.9 30 30 2NP04502046 2 20.0** 24.1 34.4 35 35 2NP04502546 2 25.0** 30.1 42 45 45 036 575-3-60 4.5 32.0 0.4 1.5 2NH04501058 1 10.0*** 9.6 13.9 15 15 2NH04501558 1 15.0*** 14.4 19.9 20 20 042 575-3-60 5.8 44.0 0.4 1.5 2NH04501058 1 10.0*** 9.6 13.9 15 15 2NH04501558 1 15.0*** 14.4 19.9 20 20 048 575-3-60 5.6 44.0 0.6 1.6 2NH04501058 1 10.0*** 9.6 14 15 15 2NH04501558 1 15.0*** 14.4 20 25 25 2NH04502058 2 20.0*** 19.2 26.1 30 30 2NH04502558 2 25.0*** 24.1 32.1 35 35 060 575-3-60 6.4 50.0 0.6 2.8 2NH04501058 1 10.0*** 9.6 15.5 20 20 2NH04501558 1 15.0*** 14.4 21.5 25 25 2NP04502058 2 20.0*** 19.2 27.6 30 30 2NP04502558 2 25.0*** 24.1 33.6 35 35 1. Dual element, time delay type. 2. Standard circuit breakers may be used in Canada and on applications over 60 amps where the heaters are separately fused. * = KW listed is for 240 volts, use table on previous page for 208 or 230 volts. ** = KW listed is for 480 volts, use table on previous page for 460 volts. *** = KW listed is for 600 volts, use table on previous page for 575 volts. Johnson Controls Unitary Products 13 36Q1Q1-XT G-B-Q5Q8 HIGH VOLTAGE CONN ' DIA. KNOCKOUT COMPRESSOR SERVICE ACCESS OMPARTMENT PANEL UNIT SIZE DIMENSION “A” G3G - G42 33 G48 - G6G 41 REFRIGERANT CONNECTIONS ELECTRICAL/FILTER SERVICE ACCESS COMPARTMENT PANEL HIGH VOLTAGE CONN. I %" DIA. KNOCKOUT .BACK SIDE RETURN AIR OPENING CLEARANCES Front 12" Back G" Left Side (Filter Access) 24" Right Side 24" Below Unit1 G" Above Unit2 Э6" (For Condenser Air Discharge...

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category