User manual York, model AFFINITY 360101-XTG-A-0108
Manafacture: York File size: 444.67 kb File name: 125dea73-7ed1-4f40-966e-1397cb464930.pdf
Language of manual:
|
![Read manual online](/images/readpdf.png)
|
|
|
Free link for this manual available at the bottom of the page
manual abstract
These are net capacity ratings. The indoor blower motor heat has already been subtracted from the gross cooling capacity ALL SENSIBLE CAPACITIES Johnson Controls Unitary Products 360101-XTG-A-0108 TABLE 7: COOLING CAPACITIES - 3-1/2 TON (DEB042) TEMPERATURE OF AIR ON OUTDOOR COIL AIR ON INDOOR COIL 1,050 CFM 1,225 1,400 1,575 1,750 WB °F WB °F WB °F WB °F WB °F 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 72 67 62 57 85 °F Net Cap MBH 40.7 39.0 36.5 34.1 42.0 40.3 37.7 35.2 43.3 41.6 38.8 36.3 43.9 42.1 39.3 36.8 44.4 42.6 39.8 37.2 Total Power Input kW 4.09 3.82 3.77 3.75 4.16 3.89 3.83 3.81 4.23 3.95 3.90 3.88 4.38 4.10 4.04 4.02 4.54 4.25 4.18 4.16 Sensible CapacityMBH1Entering DryBulb ° F 86 23.8 31.3 36.5 34.1 26.1 34.2 37.7 35.2 28.5 37.0 38.8 36.3 30.5 39.4 39.3 36.8 32.6 41.9 39.8 37.2 83 20.8 28.3 34.6 34.1 22.6 30.6 36.7 35.2 24.4 32.9 38.8 36.3 25.9 34.8 39.3 36.8 27.3 36.6 39.8 37.2 80 17.8 25.4 31.6 31.9 19.1 27.1 33.8 34.1 20.3 28.8 36.0 36.3 21.2 30.1 37.6 36.8 22.1 31.4 39.2 37.2 77 14.9 22.4 28.6 28.9 15.5 23.6 30.3 30.6 16.2 24.7 31.9 32.2 16.6 25.5 32.9 32.1 16.9 26.2 34.0 32.0 74 11.9 19.4 25.6 26.0 12.0 20.0 26.7 27.0 12.1 20.7 27.8 28.1 11.9 20.8 28.3 27.5 11.7 21.0 28.8 26.8 71 -16.4 22.7 23.0 -16.5 23.2 23.5 -16.6 23.7 24.1 -16.2 23.6 22.8 -15.8 23.6 21.6 68 -13.4 19.7 20.0 -12.9 19.6 20.0 -12.5 19.6 20.0 -11.5 19.0 18.2 -10.6 18.3 16.4 95 °F Net Cap MBH 38.7 36.7 34.0 32.7 40.1 38.1 35.2 33.9 41.6 39.4 36.5 35.2 42.1 39.9 36.9 35.6 42.6 40.3 37.4 36.0 Total Power Input kW 4.16 4.06 3.96 3.98 4.23 4.13 4.03 4.05 4.30 4.19 4.10 4.11 4.44 4.33 4.23 4.25 4.59 4.47 4.37 4.39 Sensible CapacityMBH1Entering DryBulb °F 86 23.0 30.4 34.0 32.7 25.4 33.3 35.2 33.9 27.8 36.3 36.5 35.2 29.9 38.3 36.9 35.6 32.0 40.3 37.4 36.0 83 20.0 27.4 33.2 32.7 21.9 29.8 34.9 33.9 23.7 32.2 36.5 35.2 25.2 34.1 36.9 35.6 26.7 36.0 37.4 36.0 80 17.0 24.4 30.3 30.4 18.3 26.3 32.6 32.8 19.7 28.2 35.0 35.2 20.6 29.5 36.2 35.6 21.5 30.8 37.4 36.0 77 14.0 21.4 27.3 27.5 14.8 22.7 29.1 29.3 15.6 24.1 30.9 31.1 15.9 24.8 31.5 30.9 16.3 25.6 32.1 30.8 74 11.0 18.4 24.3 24.5 11.3 19.2 25.5 25.7 11.5 20.0 26.8 27.0 11.3 20.2 26.9 26.3 11.1 20.4 26.9 25.5 71 -15.4 21.3 21.5 -15.6 22.0 22.2 -15.9 22.7 22.9 -15.5 22.2 21.6 -15.2 21.7 20.3 68 -12.4 18.3 18.5 -12.1 18.4 18.7 -11.8 18.6 18.8 -10.9 17.6 17.0 -10.0 16.5 15.1 105 °F Net Cap MBH 36.2 33.9 30.8 31.2 37.6 35.1 32.0 32.4 38.9 36.4 33.1 33.6 39.4 36.8 33.5 34.0 39.9 37.3 33.9 34.4 Total Power Input kW 4.40 4.28 4.20 4.22 4.47 4.35 4.27 4.29 4.54 4.42 4.34 4.35 4.69 4.57 4.48 4.50 4.84 4.71 4.63 4.64 Sensible CapacityMBH1Entering DryBulb ° F 86 22.4 29.3 30.8 31.2 24.8 32.1 32.0 32.4 27.3 34.9 33.1 33.6 29.3 36.1 33.5 34.0 31.4 37.3 33.9 34.4 83 19.4 26.3 30.5 31.2 21.3 28.8 31.8 32.4 23.2 31.3 33.1 33.6 24.7 33.2 33.5 34.0 26.2 35.1 33.9 34.4 80 16.4 23.3 27.8 28.8 17.7 25.3 30.1 31.2 19.1 27.2 32.4 33.6 20.0 28.6 33.1 34.0 21.0 29.9 33.9 34.4 77 13.4 20.3 24.8 25.8 14.2 21.7 26.5 27.6 15.0 23.1 28.3 29.5 15.4 23.9 28.5 29.3 15.8 24.7 28.7 29.1 74 10.4 17.3 21.8 22.8 10.7 18.2 23.0 24.1 10.9 19.0 24.2 25.4 10.7 19.3 23.8 24.7 10.6 19.5 23.5 23.9 71 -14.3 18.8 19.8 -14.7 19.4 20.6 -15.0 20.1 21.3 -14.6 19.2 20.0 -14.3 18.3 18.7 68 -11.4 15.8 16.8 -11.1 15.9 17.0 -10.9 16.0 17.2 -10.0 14.5 15.4 -9.1 13.1 13.5 115 °F Net Cap MBH 33.8 31.1 27.7 29.8 35.0 32.2 28.8 30.9 36.3 33.4 29.8 32.0 36.7 33.8 30.1 32.3 37.2 34.2 30.5 32.7 Total Power Input kW 4.64 4.51 4.44 4.46 4.71 4.58 4.51 4.53 4.78 4.65 4.58 4.59 4.94 4.80 4.73 4.75 5.09 4.96 4.88 4.90 Sensible CapacityMBH1Entering DryBulb ° F 86 21.7 28.3 27.7 29.8 24.2 30.8 28.8 30.9 26.7 33.4 29.8 32.0 28.8 33.8 30.1 32.3 30.9 34.2 30.5 32.7 83 18.7 25.3 27.7 29.8 20.7 27.8 28.8 30.9 22.6 30.3 29.8 32.0 24.2 32.3 30.1 32.3 25.7 34.2 30.5 32.7 80 15.7 22.3 25.3 27.1 17.1 24.3 27.5 29.5 18.5 26.3 29.8 32.0 19.5 27.7 30.1 32.3 20.5 29.1 30.5 32.7 77 12.7 19.3 22.3 24.1 13.6 20.7 24.0 26.0 14.4 22.2 25.7 27.9 14.9 23.0 25.5 27.7 15.3 23.8 25.3 27.5 74 9.7 16.3 19.3 21.1 10.0 17.2 20.4 22.5 10.3 18.1 21.6 23.8 10.2 18.4 20.8 23.0 10.1 18.6 20.1 22.3 71 -13.3 16.3 18.1 -13.7 16.9 18.9 -14.0 17.5 19.7 -13.7 16.2 18.4 -13.4 14.8 17.1 68 -10.3 13.3 15.2 -10.1 13.4 15.4 -9.9 13.4 15.6 -9.1 11.5 13.7 -8.2 9.6 11.9 125 °F Net Cap MBH 31.4 28.3 24.6 28.3 32.5 29.3 25.5 29.3 33.6 30.4 26.4 30.3 34.0 30.7 26.7 30.7 34.5 31.1 27.1 31.1 Total Power Input kW 4.9 4.7 4.7 4.7 4.9 4.8 4.7 4.8 5.0 4.9 4.8 4.8 5.2 5.0 5.0 5.0 5.3 5.2 5.1 5.2 Sensible CapacityMBH1Entering DryBulb ° F 86 21.1 27.2 24.6 28.3 23.6 29.6 25.5 29.3 26.1 31.9 26.4 30.3 28.3 31.5 26.7 30.7 30.4 31.1 27.1 31.1 83 18.1 24.2 25.0 28.3 20.0 26.8 25.7 29.3 22.0 29.4 26.4 30.3 23.6 31.3 26.7 30.7 25.2 33.3 27.1 31.1 80 15.1 21.3 22.8 25.5 16.5 23.3 25.0 27.9 17.9 25.3 27.2 30.3 19.0 26.7 27.1 30.7 20.0 28.2 27.1 31.1 77 12.1 18.3 19.8 22.5 13.0 19.7 21.4 24.4 13.9 21.2 23.1 26.3 14.3 22.1 22.5 26.1 14.8 23.0 21.9 25.9 74 9.1 15.3 16.8 19.5 9.4 16.2 17.9 20.8 9.8 17.1 19.0 22.2...
|