Login:
Votes - 0, Average rating: 0 ( )

User manual LG, model P03AH

Manafacture: LG
File size: 696.01 kb
File name:
Language of manual:en
Photos and specs  LG  P03AH
Free link for this manual available at the bottom of the page



Other manuals for this model:

manual abstract


6. Auto Airflow Direction Control Button • The vertical louvers swings left and right. 1 7. Turbo-Z Cooling Operation Button 8. Indoor Fan Speed Selection Button • To select the desired fan speed in two steps [Low, Mid, 9 High] 10 9. Cooling ON Button 11 10. Heating Button (Heat Pump Model Only) Auto Operation Button (Cooling Model Only) 6 12 11. Soft Dry Operation Button 12. Energy Saving Operation Button(Cooling Model 13 Only) 14 13. Power ON/OFF Button • Operation will start when this button is pressed, and stop when the button is pressed again. 14. Temperature Setting Buttons 15. Electric Heater ON/OFF Button(Heat Pump & Electric Heater Product Only) Wireless Remote Control Puts all functions at your fingertips Handling the remote control • Aim at the signal receptor on the floor standing type air conditioner when operating. • The remote control signal can be received at a distance of up to about 7meters. • Be sure that there are no obstructions between the remote control and the signal receptor. • Do not drop or throw the remote control. • Do not place the remote control in a location exposed to direct sunlight, or next to a heating unit, or other heat source. Owner's Manual 9 Operating Instructions Remote Control Preparation 1. How to mount onto a wall Use the screws to secure the holder to the wall or attach the holder side of indoor unit. 2. To insert the remote control to the holder. • Please keep it on the right side of indoor unit. When opening When closing Insert Pull How to insert batteries • Do not use rechargeable batteries remote controller. 1. Remove the cover from the back of the such batteries as different from standard dry cells in shape, direction. • Slide the cover according to the arrow dimensions, and performance. • Change the batteries with a new 2. Insert two batteries. one if the remote control does not correct. • Be sure that the (+) and (-) directions are work properly after using for an extended length of time. • Be sure that both batteries are new. 3. Re-attach the cover. • Slide the cover into back position. 10 Floor Standing-Type Air Conditioner Operating Instructions ENGLISH 23451AfterN 4 seconds To raise the temperatureN To lower the temperature A/CL TURBO-Z TURBO-Z Low High Mid ON/OFFSETN TEMP ON/OFFTEMP N ROOM PLASMA ON/OFF ON/OFFSETN TEMP ON/OFFSETN TEMP ON/OFFSETN TEMP Cooling Operation Mode Press the on/off button.(or touch the anyplace of touch panel and touch the on/off key) Select Cooling Operation. Press the Cooling Operation Button on the remote controller (or Touch the Cooling Operation key on the touch panel) Set the temperature lower than the room temperature. The temperature can be set within a range of 16°C~30°C by 1°C. When you finish the temperature setting. Set the Fan Speed. qEach time the Fan Speed Button is pressed (or fan speed key is touched), the Fan Speed mode is shifted in the arrow direction. Owner's Manual 11 Operating Instructions 231To raise the temperatureN To lower the temperature A/CL TURBO-Z TURBO-Z Low High Mid PLASMA ON/OFF ON/OFFSETN TEMP. ON/OFFSETN TEMP. ON/OFFN ROOM TEMP Soft Dry Operation Press the on/off button.(or touch the anyplace of touch panel and touch the on/off key) Select Soft Dry Operation Press the Soft Dry Operation Button on the remote controller (or Touch the Soft Dry Operation key on the touch panel) Set the temperature lower than the room temperature. The temperature can be set within a range of 16°C~30°C by 1°C. During softy Dry Operation • The indoor fan speed is automatically set to low and can be set fan speed. 12 Floor Standing-Type Air Conditioner Operating Instructions ENGLISH TURBO-Z TURBO-Z 231TURBO-Z A/CL PLASMA ON/OFF ON/OFFSETN TEMP TURBO-Z Turbo-Z cooling Operation Press the on/off button.(or touch the anyplace of touch panel and touch the on/off key) Press the Turbo-Z Cooling button to operate the speed cooling mode and the unit will operate in super high fan speed on cooling mode. To cancel the Turbo-Z Cooling mode, press the Turbo-Z Cooling button or the Auto Swing Direction Control Button (Up & Down, Left & Right) and the unit will operate in Med Fan speed mode on cooling mode. To cancel the Turbo-Z Cooling mode, press the Turbo-Z Cooling button again or the Auto Swing Direction Control Button (Up & Down, Left & Right) and the unit will operate in Med. Fan speed on cooling mode. oDuring the Turbo-Z Cooling function at any moment, the A/C starts to blow the cool air at extremely high speed setting the room temp. automatically to 18°C. It is especially used to cool the room temp. in the shortest time in a hot summer. In heat pump mode or neuro fuzzy mode however, the Turbo-Z Cooling function is not available. oIn order to return to the normal cooling mode from the Turbo-Z Cooling mode, you just press either the operation mode selection button, airflow volume selection or temp. setting button or the Turbo-Z Cooling button again. NOTICE Owner's Manual 13 Operating Instructions A/CL TURBO-Z TURBO-Z 2341T...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category