Target temp : Indoor air Temp. S/W #4 MASTER remote controller SLAVE remote controller S/W #5 Self Test Mode is NOT available Self Test Mode is available S/W #6 Emergency Operation OFF Emergency Operation ON S/W #7 .C .F S/W #8 No Use No Use 46_ Appendix maINTaINING THE UNIT maintenance activities • In order to ensure optimal availability of the unit, a number of checks and inspections on the unit and the field wiring have to be carried out at regular intervals, preferably yearly. This maintenance should be carried out by SAMSUNG local technician. Besides keeping the remote controller clean by means of a soft damp cloth, no maintenance is required by the operator. During longer periods of standstill, e.g. during summer with a heating only application, it is very important NOT TO SWITCH OFF THE POWER SUPPLY towards the unit. Switching off the power supply stops the automatic repetitive movement of the motor in order to prevent it from getting jammed. WARNING This product contains fluorinated greenhouse gases covered by the kyoto Protocol. Refrigerant type: R410A GWP(1) value: 1975 (GWP = global warming potential) • Periodical inspections for refrigerant leaks may be required depending on European or local legislation. Please contact your local dealer for more information. ENGLISH Appendix TRoUbLESHooTING TIPS If the unit has some problem to work properly, error codes will be displayed on the wired remote controller. The following table describes the explanation of the error codes. Display Explanation EVA Inlet temp sensor SHORT or OPEN EVA Outlet temp sensor SHORT or OPEN Wired remote controller temp sensor SHORT or OPEN FRAM Read/Write Error(Wired remote controller data error) Water Inlet temp sensor SHORT or OPEN PHE Outlet temp sensor SHORT or OPEN Water outlet (Back up Heater) temp sensor SHORT or OPEN Water TANK temp sensor SHORT or OPEN Ref' In Ref' out Water Outlet E902Tr1 Tw2 Tw1 Water inlet E901 EVA inlet E122 Wired remote controller temp sensor E653 PHE E123 E654 Water tank Outdoor temp sensor Unit E904 48_ Appendix Appendix _49 ENGLISH Communication Display Explanation Abnormal communication B/W Wired remote controller & Hydro Unit Communication tracking error B/W Wired remote controller & Hydro Unit FRAM Read/Write Error(Wired remote controller data error) E654 • Wrong data transmit B/W micom & IC07(eeprom) E601, E604 Appendix TRoUbLESHooTING TIPS Water pump & flow S/W Display Explanation Flow S/W OFF error (In case of flow S/W OFF in 10s during water pump signal is ON) Flow S/W OFF error (In case of flow S/W ON in 60s during water pump signal is OFF) E911 • Water pump ON ( Flow S/W off ) • Water pump ON ( Flow S/W off ) : NOT enough water flow Water ow(>12LPM)Water flow < 16 LPM E912 • Water pump OFF ( Flow S/W on ) Water flow > 16 LPM 50_ Appendix ERRoR CodES If the unit has some problems and does not work normally, error code is shown on the OUTDOOR UNIT main PBA or LCD of the wired remote controller. Display Explanation Error Source 101 Hydro Unit / OUTDOOR UNIT wire connection error Hydro Unit, OUTDOOR UNIT 162 EEPROM Error Hydro Unit 201 Hydro Unit/OUTDOOR UNIT communication error (Matching error) Hydro Unit, OUTDOOR UNIT 202 Hydro Unit/OUTDOOR UNIT communication error (3 min) Hydro Unit, OUTDOOR UNIT 203 Communication error between INVERTER and MAIN MICOM (6 min) OUTDOOR UNIT 221 OUTDOOR UNIT temperature sensor error OUTDOOR UNIT 231 condenser temperature sensor error OUTDOOR UNIT 251 Discharge temperature sensor error OUTDOOR UNIT 320 OLP sensor error OUTDOOR UNIT 403 Detection of OUTDOOR UNIT compressor freezing (During cooling operation) OUTDOOR UNIT 404 Protection of OUTDOOR UNIT when it is overload (during Safety Start, Normal operation state) OUTDOOR UNIT 416 Discharge of a compressor is overheated OUTDOOR UNIT 419 OUTDOOR UNIT EEV operation error OUTDOOR UNIT 425 Power source line missing error (only for 3-phase model) OUTDOOR UNIT 440 Heating operation blocked (outdoor temperature over 35°C) OUTDOOR UNIT 441 Cooling operation blocked (outdoor temperature under 9°C) OUTDOOR UNIT 458 OUTDOOR UNIT fan1 error OUTDOOR UNIT 461 [Inverter] Compressor startup error OUTDOOR UNIT 462 [Inverter] Total current error/PFC over current error OUTDOOR UNIT 463 OLP is overheated OUTDOOR UNIT 464 [Inverter] IPM over current error OUTDOOR UNIT 465 Compressor V limit error OUTDOOR UNIT 466 DC LINK over/low voltage error OUTDOOR UNIT 467 [Inverter] Compressor rotation error OUTDOOR UNIT 468 [Inverter] Current sensor error OUTDOOR UNIT 469 [Inverter] DC LINK voltage sensor error OUTDOOR UNIT 470 EEPROM read/write error OUTDOOR UNIT 471 [Inverter] OTP error OUTDOOR UNIT ENGLISH Appendix _51 Appendix ERRoR CodES Display Explanation Error Source 474 IPM(IGBT Module) or PFCM temperature sensor Error OUTDOOR UNIT 475 OUTDOOR UNIT fan2 error OUTDOOR UNIT 484 PFC Overload Error OUTDOOR UNIT 485 Input current sensor error OUTDOOR UNIT 500 IPM is overheated OUTDOOR UNIT 554 Gas leak error OUTDOOR UNIT 601 Communi...
Other models in this manual:Air Conditioner & Split Systems - AEN160YDEHA (5.6 mb)
Air Conditioner & Split Systems - AEN160YDGHA (5.6 mb)