1. Specification Models AS-W1838RH0 [LA185HV] AS-W2438RH0 [LA245HV] Cooling Capacity kW 1.76~5.28~5.80 3.87~7.03~7.74 Btu/h. 6,005~18,000~19,790 13,200~24,000~26,400 Heating Capacity kW 1.40~6.07~6.65 3.37~8.09~8.88 Btu/h. 4,776~20,700~22,690 11,500~27,600~30,300 Power Input Cooling/Heating W 1,640/1,770 2,450/2,900 Running Current Cooling/Heating A 7.3/8.3 11.0/13.0 Starting Current Cooling/Heating A 7.3/8.3 11.0/13.0 EER W/W 3.22 2.87 Btu/h.W 11.0 9.8 COP W/W 3.43 2.79 Power Supply O / V / Hz 1/208-230/60 1/208-230/60 Power Factor % 98 97 Air Flow Rate Indoor,Max m3/min(CFM) 18.5(650) 20.3(717) Outdoor,Max m3/min(CFM) 42(1,483) 58(2,048) Moisture Removal l/h. 2.1 2.7 Sound Level Indoor,H/M/L dB(A)+3 40/38/34 45/40/37 Outdoor,Max dB(A)+3 53 54 Refrigerant & Charge (at 7.5 m) g(oz) R410A, 1,200(42) R410A, 1,800(63.5) Additional Refrigerant charge g/m(oz/ft) 20(0.22) 30(0.32) Compressor Type Rotary Rotary Model 5CS130XCA03 5KD240XCA21 Motor Type BLDC BLDC Oil Type RB68A FV50S Oil Charge cc 360 900 O.L.P. name -- Fan(Indoor) Type Cross Flow Fan Cross Flow Fan Motor Output W 20 24 Fan(Outdoor) Type Propeller Propeller Motor Type AC Induction AC Induction Motor Output W 79 79 Circuit Breaker* A 20 25 Power Supply Cable AWG 14 12 Power and Transmission Cable No.*mm2+ AWG 18 18 Piping Connections Liquid Side mm(in) 6.35(1/4) 9.52(3/8) Gas Side mm(in) 12.7(1/2) 15.88(5/8) Drain Hose O.D., I.D. mm(in) 21.5,16(0.85,0.63) 21.5,16(0.85,0.63) Dimensions Indoor (W*H*D) mm 1,107*299*200 1,107*299*200 inch 43.6*11.8*7.9 43.6*11.8*7.9 Outdoor (W*H*D) mm 870*655*320 870*800*320 inch 34.3*25.8*12.6 34.3*34.6*12.6 Net Weight Indoor kg(lbs) 14.1(31.1) 14.1(31.1) Outdoor kg(lbs) 46(101.4) 60(132.3) Operation Range Cooling(Outdoor) °C(°F) -10 ~ 46 (14.0~114.8)(Low Ambient) -10 ~ 46 (14.0~114.8)(Low Ambient) Heating(Outdoor) °C(°F) -10 ~ 24 (14.0 ~ 75.2) -10 ~ 24 (14.0 ~ 75.2) Max. Piping Length m(ft) 15(49) 30(98) Max. Elevation Difference m(ft) 7(23) 15(49) Tool Code(Chassis) Indoor + Outdoor S8 + UE S8 + UE1 Functions Temperature Control Thermistor Thermistor Plasma Filter NEO NEO Prefilter(washable/anti-fungus) O O Auto Clean O O CHAOS Wind(Auto Wind) O O Steps, Fan/Cool/Heat 3/4/4 3/4/4 Airflow Direction Control(up & Down) Auto Auto Airflow Direction Control(left & right) Auto Auto Remote Controller Type Wireless LCD Wireless LCD Setting Temperature Range Cooling 18 ~ 30 (64~86) 18 ~ 30 (64~86) Heating 16 ~ 30 (60~86) 16 ~ 30 (60~86) Auto Operation (Micom Control) -- Auto Changeover (Micom Control) O O Self Diagnosis O O Timer 24h On/Off 24h On/Off Sleep Operation O O Soft Dry Operation O O Restart Delay(minute) 2 2 Deice Control(Defrost) O O Hot Start O O Jet Cool / Heat O O Low Ambient Operation O O Special Function -- Network Functions Dry Contact -- Network Solution -- PI485 -- Note: . Some of functions are slightly different depending upon models. O : Applied, - : No relation . The specification may be subject to change without prior notice for purpose of improvement. * For circuit breaker rating, please conform to local standards wherever necessary. . Capacity : based on 230V Copyright ©2007 LG Electronics. Inc. All right reserved. - 2 LGE Internal Use Only Only for training and service purposes 2. Piping Diagrams Indoor Unit Outdoor Unit...

Other models in this manual:
Air Conditioner & Split Systems - AS-W2438*H0 (2.75 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category