|
manual abstract
Among other features, this versatile unit exhausts all the condensate that it extracts from your air. Additionally, this portable air conditioner features auto restart. If power to the unit is interrupted, the unit “remembers” its previous settings when power is restored. In order to properly use all features of this portable air conditioner, please read this owner’s manual prior to use and store the owner’s manual for future reference. It is also a good idea to save the box and packaging for this portable air conditioner for off-season storage. Energy Saving Tips 1. Use the portable air conditioner for the recommended room size. Rooms that are too small can cause the unit to short cycle and work inefficiently. Rooms that are too large will never cool completely. 2. Be careful not to obstruct the air flow coming out of the portable air conditioner. A powerful, unobstructed airflow is crucial for optimum cooling. 3. Keep blinds and curtains closed during the sunniest part of the day. 4. Clean the pre-filter often. 5. Close your fireplace damper, floor grills, and wall grills to prevent cool air from escaping. 6. Avoid opening doors frequently. 7. Note that each additional person in room adds between 100-150 BTU of heat, so the more people in a room, the more cooling capacity is required. 8. Set the portable air conditioner to maximum cooling and high speed airflow when you first start it up, and then adjust the unit to a comfortable setting. 9. To provide cooling to a room, this portable air conditioner must always be used with its exhaust hose attached. Notes The portable air conditioner must be plugged into an appropriate power outlet. Refer to the rating label on the back of the unit for more information. The portable air conditioner is a compressor-driven cooling system. The air conditioner has an anti-overheating safety feature that delays the compressor from starting for three minutes after the air conditioner turns on or when a mode change is made. If the compressor does not immediately start, it is likely because of this feature. To protect the compressor from overheating or freezing, it will only operate when the ambient temperature is between 64° and 100°F. In the Cooling, Dehumidifying, or Auto modes the exhaust hose must be used. When switching into the Cooling mode, cooling may be temporarily delayed as the unit cools down. Technical Specifications Model PAC9000W Electrical Power Supply 115 Volts / 60 Hertz Rated Power Consumption During Cooling See Label on Unit Dehumidification Capacity 38 Pints per 24 Hours Refrigerant R22 Refrigerant Load 500g Fan Speeds 2 Airflow (H/L) 200/150 CFM Noise Level 52dB(A) Dimensions (HxWxD) 31.42"x14"x13.82" Net Weight 55 Pounds Timer 0.5-24 hours Notes: 1) The above data were obtained in the following conditions: Cooling conditions: Dry bulb/Wet bulb: 95/75°F according to European standard EN14511-2004 2) Operating limits for cooling: Maximum ambient conditions: Dry bulb/Wet bulb: 100/80° F Minimum ambient conditions: Dry bulb/Wet bulb: 64/57°F Safety Precautions B A C 1. Do not insert anything into the grill (Fig. A.) 2. Make sure all children are properly supervised around this portable air conditioner (Fig. B.) 3. Do not use an excessively wet cloth or industrial solvents to clean this unit (Fig. C.) 4. Do not damage the power cord (Fig. D.) 5. Do not use the portable air conditioner in the presence of flammable substances or vapors such as alcohol, insecticides, gas, etc (Fig. D.) 6. Do not yank on the power cord or place it near a source of heat. If the electric cord is damaged, it must be replaced by an authorized service agent (Fig. D.) 7. Transport the portable air conditioner in an upright position only. If the unit is tipped over, make sure it stands upright for at least 3 hours prior to turning it on. 8. Always place the unit on a level surface. 9. In order to cool, the hot air from the exhaust port in the rear of the portable air conditioner must be exhausted outside the room. 10. Make sure the portable air conditioner is connected to a grounded power outlet. 11. This portable air conditioner is designed to operate in an ambient temperature of 64°-100° F. 12. This portable air conditioner has been designed for residential use. 13. Always turn the portable air conditioner off before unplugging it. 14. Do not use this portable air conditioner for functions other than those described in this owner’s manual. 15. Do not tilt the portable air conditioner. 16. Do not cover or obstruct the intake or outlet grills. 17. Do not use the portable air conditioner in a wet room- such as a bathroom or laundry room- to avoid the possibility of shock. 18. Do not bend or crush the exhaust hose while in use. 19. Do not sit on, or place articles on, the portable air conditioner. 20. Do not touch the portable air conditioner with wet or damp hands. 21. Do not let chemical substances come into contact with the portable air conditioner. 22. Do not use the plug to start or ...
Other models in this manual:Air Conditioner & Split Systems - PAC9000 (1.19 mb)
Air Conditioner & Split Systems - PAC9000 (1.19 mb)
Air Conditioner & Split Systems - PAC9000 (1.19 mb)
Air Conditioner & Split Systems - PAC9000 (1.19 mb)