manual abstract


or no. (905) 2381313 in Canada. SPECIFICATIONS Power supply voltage V 110-120 Frequency Hz 60 Cooling capacity: With water Btu 8500* With air Btu 7500* Current consumption A/W 6,5/ 990 Water tank capacity pints 30.65 Air flow capacity cfm. 212 Room thermostat (34° to 102°F) adjustable Dimensions: width in. height in. depth in. 22”,05 28”,74 15”,35 Net weight lbs. 97 Refrigerant system (freon) R 22 Compressor protection Overload relay Freon charge lb. (gr) see rating label *Data according to pending standard testing procedures subject to review by the U.S. Dept. of Energy. OPTIMUM OPERATING RANGE ROOM TEMPERATURE 70°F - 90°F ROOM HUMIDITY FACTOR 50% - 80% RH POWER SUPPLY FREQUENCY 60 HZ VOLTAGE 115V ILLUSTRATED MAIN FEATURES LIST Air outlet grid Control panel Programmer (timer) Water container Castor Castor stops Water collecting tray Water container compartment door Air filter Air intake grid Exhaust hose Power cable comp. Manually resettable red button Handle Water collecting tray drainage tube ILLUSTRATED ACCESSORY LIST Table 1 Table 1 DESCRIPTION SUPPLIED Exhaust hose 1 Permanent wall vent 1 Caster stop 2 Descaling fluid 1 Window nozzle 1 Adjustable window bracket 1 Suction disc 2 ACCESSORY CHECK Check that all parts listed in Table 1 are included. PERMANENT INSTALLATION The Pinguino accessories include one wall vent for exhausting your Pinguino. Once installed, this vent is the only item needed for using Pinguino. fig. 1 Permanent installation outlet holes must be in an exterior wall and opening diameter should not exceed 4”1/2. INSIDE OUTSIDE INSIDE OUTSIDE A1 A2 fig. 2 fig. 3 in a window pane through the wooden base- section of a door or window 4” .17 4” .17 ............ INSIDE OUTSIDE A3 through the wall 4” .17 1” fig. 4 In case of fixed installation, air discharged from rear hose has been extracted from the room where the appliance is installed. Check that the room (especially if small) is not “air-tight”; a drop in pressure would cause irregular functioning, which could consequently activate reset switch. Air entering through door and window cracks is normally sufficient. If deemed, necessary leave a door ajar (approx. 1/2 inch is enough). TEMPORARY INSTALLATION Note: In both cases (permanent and temporary installations) make sure that the Pinguino is positioned on level ground. If necessary use the two caster stops for the front casters This installation makes it easy to Suction discs may be used to use Pinguino in any room, keep window or door closed (Fig. provided there is a window or a 6). door: it allows you to use the Pinguino immediately (Fig. 5). Note: Additional exhaust hoses are available through De longhi America. For best results we do not recommend using more than one. Pinguino is equipped with an adjustable window bracket. If you have a sash window, place the bracket on the window sill, extend the bracket fully within the window frame and lower the window onto the bracket. Insert the nozzle of the exhaust hose into the slot, then connect the hose to the air conditioner (Fig. 7). Thanks to the wing nut, it’s possible to use the window bracket also for sliding windows. Position the hole of the 1 2 bracket so to allow a correct installation of the exhaust hose (see the following instructions). PREPARING THE UNIT FOR USE 1) Fit the exhaust tube in place; if your conditioner is supplied with a bayonet tube, it is fitted as illustrated in the diagram. 2) For permanent installation, place the appliance near the wall or window outlet. Make sure it is standing on a level surface and fit the special shock absorbers/castor stops underneath the castors. 1) Water collects at this point 2) Bend this section 3) Bend this section NO YES YES fig. 5 fig. 6 fig. 7 fig. 8 window bracket ELECTRICAL CONNECTION Check that the power supply voltage is 115 V ~ 60 Hz. Important: if you need to use and extension cord, please be sure to use a heavy duty extension cord (minimum 14 gauge). Before connecting the Pinguino to power supply, make sure that all switches on the front control panel are in the OFF position. Connect power cord found in storage compartment at rear of the Pinguino (Fig. 9). fig. 9 FINAL CHECK In order to obtain the maximum performance from your air-conditioner make sure that: fig. 10 -Doors and windows of room to be air- conditioned are closed (with the exception of temporary installation where a partially opened window is necessary). fig. 12 fig. 11 fig. 13 -Shade the room as far as possible from direct sunlight by drawing curtains and/or lowering blinds or shutters, for economical and efficient air-cooling. -Ensure that intake and outlet vents (fig. 2 and 3) are not blocked. -Make sure there are no sources of heat in the room. SPECIAL NOTE This machine is designed to be used with or without water. Maximum performance is obtained using water. When used without water, Pinguino will maintain a full 88% of its cooling capacity. HOW TO PREPARE WATER CONTAINER Use only clean, salt-free tap water. ...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category