When set to "silent", the appliance works very silently at a power of between 2.350 W and 1.950 W. o The appliance lowers the temperature and dries the air in the room at the same time in order to create ideal air conditions. o If the appliance turns itself off automatically via thermostat, then it is necessary to wait until room temperature rises 2°C before it comes back on again. o Condensed water formed during air conditioning evaporates automatically and is expelled outdoors, together with hot air, through the hot- air expulsion duct. In conditions of extreme humidity, the appliance accumulates condensed water in an internal tank. When the water in the tank reaches a certain level, the appliance turns itself off automatically and the red indicator light flashes to indicate that the tank needs to be emptied. o Water is removed via the drainage tube fixed onto the back of the appliance at the bottom. o Water can also be removed as per dehumidification using the pump installed on the appliance. First, turn the appliance off and wait for ten minutes in order to allow the cold flow to stabilise. Then follow the instructions as set out in "Dehumidification". It takes approximately one minute to empty the condensed water tank using the pump installed. Ways of releasing air outdoors Temporary installation o Connect the diffusion duct to the hot-air expulsion duct. o Leave the window ajar and feed the air–expulsion nozzle through the gap. On windows with double frames, feed the expulsion nozzle through the gap in the middle. o Close the window as much as possible and secure it in place using the suction pad provided. 33 Permanent installation The appliance can be installed on a permanent basis using window/wall Optional Accessory, reference S1 RKZ 06009, available from your supplier. o A hole must be made in the wall and the wall accessory fitted in order to expel hot air. o Store the diffusion duct away and connect the air expulsion duct to the accessory. o Only the transparent end section of the accessory is used when air is to be expelled through a window on a permanent basis. A 10.5-cm. diameter hole must be made in the glass in order to fit the accessory. N.B. • Do not extend the hot-air expulsion duct more than necessary (maximum length: 140 cm.). • There must be a distance of at least 70 cm. between the floor and the end of the duct. • Do not bend the duct too sharply when positioning it. This can impede proper hot-air expulsion, which may reduce cooling efficiency. 35 Dehumidification When set to, the appliance removes humidity from the atmosphere. As a result, there is no temperature regulation. o Turn drainage stopcock 90° in an anti-clockwise direction. o Remove stopcock plug and insert drainage pipe. stored in the main filter compartment. o Place a bowl at the drainage pipe outlet to collect the condensed water in. o Put the air extraction duct in storage position. o Select the "Dehumidification" function with the mode button. Fig. 7. o The dehumidification function only works in manual mode. The automatic "turbo" and "silent" modes are not available for this function. o Manual mode is activated by pressing the "speed" button once. The symbol flashes to indicate the selection. You have two seconds to select ventilator speed using buttons < (down) and > (up). The LCD screen indicates the ventilator speed selected. o The amount of humidity removed from the atmosphere can reach as much as max. 30 litres of water/ 24 hours depending on room atmosphere conditions and the ventilator speed selected. Warning! Do not forget to put the plug back in place on the drainage stopcock and to turn the stopcock 90° in a clockwise direction before setting the appliance to the temperature control setting. The appliance will shed water should you fail to do so. If the "Dehumidification" indicator light flashes, atmospheric temperature is lower than 18°C. This temperature is the lowermost limit for operation of the dehumidification function and the appliance turns itself off. 23:00 7 Air purification 23:00 8 The appliance comes with a main filter with a double active purifying filter. This special filter is for smells and smoke, pollen, bacteria and dust. There is no temperature regulation for the air purification function. o Put the air expulsion duct in the same position as for dehumidification. o Select the "Air purification" function with the mode button. Fig. 8. o The air purification function only works in manual mode. The automatic "turbo" and "silent" modes are not available for this function. Manual mode is activated by pressing the "speed" button once. The symbol flashes to indicate the selection. You have two seconds to select ventilator speed using buttons < (down) and > (up). The LCD screen indicates the ventilator speed selected. Depending on the ventilator speed selected, the amount of air processed varies from 125 m3/h (level 1) to 295 m3/h (level 5). o The appliance is fitted with a change filter indicato...
Other models in this manual:Air Conditioner & Split Systems - S1RKM10012/02 (2.74 mb)
Air Conditioner & Split Systems - S1RKM10012/03 (2.74 mb)
Air Conditioner & Split Systems - S1RKM10012/04 (2.74 mb)