Manafacture: Samsung
File size: 1 mb
File name:
|
manual abstract
E-17 Press the button. N NNNNo oooot tttte eeeeIf you want to turn off the air conditioner before the timer reaches the setting time, press the button. Setting the Sleep Timer E-18 The Sleep Timer can be used when you are cooling your room to switch the air conditioner off automatically after a period of six hours. N NNNNo oooot tttte eeeeIf you wish to switch the unit off at a specific time, refer to page 17. 1 Make sure that you have selected the Cool mode. 2 Press the button one or more times until the indicator appears on the remote control. Result: The indoor unit beeps. . The air conditioner will be controlled as indicated in the illustrations below. Cooling The desired temperature is increased by 1°C every hour. When it has been increased by 2°C (after two hours), the temperature is maintained for four hours. To Cancel the Sleep Timer If you no longer wish to use the Sleep Timer that you have set, you can cancel it at any time. Press the button. Result: The indoor unit beeps. The indicator is no longer displayed. The air conditioner operates normally. Setting the 1 Hour Timer The 1 Hour Timer enables each mode to operate only for an hour and stop automatically with just one touch of the 1 Hour Timer button. It is good for you when you feel setting the Off Timer by pressing the Off Timer button several times is unnecessary and inconvenient. 1 Press the button one or more times until the indicator appears on the remote control. Result: The indoor unit beeps. The air conditioner will stop operating after an hour automatically. 2 To select an operating mode under the set 1 Hour Timer, press the button until the desired mode is displayed at the remote control. Result: The air conditioner will run and stop operating in the selected mode with the 1 Hour Timer set. N NNNNo oooot tttte eeeeIf you operate the 1 Hour Timer when the air conditioner is turned off, the air conditioner will start operating and be turned off after an hour. To cancel the 1 Hour Timer If you no longer wish to use the 1 Hour Timer that you have set, you can cancel it at any time. Press the button. Result: The indoor unit beeps. The indicator is no longer displayed. The air conditioner operates normally. E-19 The following table indicates the temperature and humidity ranges within which the air conditioner can be used. If the air conditioner is used at... High temperatures Mode Outdoor Temperature Cooling 19°C to 43°C approx. Drying 19°C to 43°C approx. . If the cooling operation is used at over 32°C(indoor temperature) then, it does not cool at its full capacity. Low temperatures High humidity levels E-20 Operating Recommendations Temperature and Humidity Ranges Here are a few recommendations that you should follow when using your air conditioner. Topic Recommendation Power failure If a power failure occurs when the air conditioner is operating, the unit is switched off. When the power returns, the air conditioner starts up again automatically. Then... The automatic protection feature may be triggered and the air conditioner stopped. Indoor Temperature Indoor Humidity 16°C to 32°C approx. 80% or less 16°C to 32°C approx. - A water leak or some other malfunction may occur if the heat exchanger freezes. Water may condense on and drip from the surface of the indoor unit if it is used for long periods. Operating Your Air Conditioner Without the Remote Control Your air conditioner can be operated directly from the indoor unit if the remote control is lost or broken. 1 To button the air conditioner on, press the On/Off button on the right side of the indoor unit. Result: The Operation indicator on the indoor unit comes on. . The indoor unit beeps. . The air conditioner starts up in the most suitable mode for the room temperature. Room Temperature Operation 24°C or above Comp On Below 24°C Comp Off 2 To button the air conditioner off, press the On/Off button again. N NNNNo oooot tttte eeeeEven if the air conditioner has been switched on via the On/Off button, operations can still be controlled using the remote control as usual. E-21 E-22 Solving Common Problems Explanation/Solution Check that the breaker used for the air conditioner is switched on. Check that the operation indicator on the indoor unit is on; if necessary press the button on the remote control. Check whether the Timer indicator on the indoor unit is switched on. If so: - Wait until the switch-on time is reached and the air conditioner starts up automatically - Cancel the timer (see pages 16 and 17 for further details) Check that there are no obstacles between you and the indoor unit. Check the remote control batteries. Check that you are close enough to the indoor unit (seven meters/ yards or less). Check that you are pointing the remote control at the remote control sensor in the right of the indoor unit. Replace the remote control batteries if necessary. Check that the correct operating mode has been selected (Auto, Cool). The room temperature may be too ...
Other models in this manual:Air Conditioner & Split Systems - ASK12WHWD (1 mb)
Air Conditioner & Split Systems - IASK09WHWB/SET (1 mb)
Air Conditioner & Split Systems - IASK09WHWDAAAE (1 mb)
Air Conditioner & Split Systems - IASK09WHWE/XME (1 mb)