|
Other manuals for this model:
manual abstract
The appearance of the unit may be different from the diagram depending on the model. Model L H ..09/12/18.. 15 7 ..24.. 20 8 Make at least one round: It will reduce noise and vibration 'L' m as maximum pipe length and 3 m as minimum pipe length (It will reduce noise and vibration) Choosing the installation location Boracay EUR_AQ09T&U@_IBIM_32447A_E.indd 24 2011-3-19 10:07:58 25 ENGLISH Space Requirements for Outdoor Unit When installing 1 outdoor unit When installing more than 1 outdoor unit 300 or more .When the air outlet is opposite the wall 1500 or more .When the air outlet is towards the wall 300 or more 150 or more 600 or more .When 3 sides of the outdoor unit are blocked by the wall 1500 or more 2000 or more .The upper part of the outdoor unit and the air outlet is towards the wall 500 or more300 or more .The upper part of the outdoor unit and the air outlet is opposite the wall .When the walls are blocking front and the rear side of the outdoor unit 300 ormore 1500 ormore Top view Side view Air outlet Air intake Air intake Air outlet .Figure Description ., Air flow direction. (Unit:mm) (Unit:mm) 1500 or more .When the air outlet is towards the wall .When 3 sides of the outdoor unit are blocked by the wall 300 or more 300 or more 600 or more 600 or more 600 or more Boracay EUR_AQ09T&U@_IBIM_32447A_E.indd 25 2011-3-19 10:08:00 25 ENGLISH Space Requirements for Outdoor Unit When installing 1 outdoor unit When installing more than 1 outdoor unit 300 or more .When the air outlet is opposite the wall 1500 or more .When the air outlet is towards the wall 300 or more 150 or more 600 or more .When 3 sides of the outdoor unit are blocked by the wall 1500 or more 2000 or more .The upper part of the outdoor unit and the air outlet is towards the wall 500 or more300 or more .The upper part of the outdoor unit and the air outlet is opposite the wall .When the walls are blocking front and the rear side of the outdoor unit 300 ormore 1500 ormore Top view Side view Air outlet Air intake Air intake Air outlet .Figure Description ., Air flow direction. (Unit:mm) (Unit:mm) 1500 or more .When the air outlet is towards the wall .When 3 sides of the outdoor unit are blocked by the wall 300 or more 300 or more 600 or more 600 or more 600 or more Boracay EUR_AQ09T&U@_IBIM_32447A_E.indd 25 2011-3-19 10:08:00 26 Choosing the installation location (Unit : mm) . When the upper part of the outdoor unit and the air outlet is opposite the wall . When the walls are blocking front and the rear side of the outdoor units . When front and rear side of the outdoor unit is towards the wall 500 or more 300 or more 500 or more 300 or more 300 or more 1500 or more 600 or more 600 or more 1500 or more 600 or more 3000 or more 200 or more 3000 or more • If installation is done in inappropriate space, unit may generate sound and cause bad effect on the product. • Installation must be done in level and in a place where vibration will not cause any effect. Accessories The following accessories are supplied with the air conditioner: • The number of each accessory is indicated in parentheses. Accessories in the indoor unit case Accessories in the outdoor unit case Installation Plate (1) Remote controller (1) Batteries for Remote controller (2) User’s & Installation Manual (1) 5-wire Assembly Cable (1) Drain Plug (1) Rubber Leg (4) • The flare nuts are attached to the end of each pipe of an evaporator or a service port. Use the nuts when connecting the pipes. • The 5-wire assembly cable is optional. If it is not supplied, use the standard cable. • The drain plug and rubber leg are only included when the air conditioner is supplied without the assembly pipe as seen in the picture below. Boracay EUR_AQ09T&U@_IBIM_32447A_E.indd 26 2011-3-19 10:08:04 ENGLISH 27 • Make sure to drill only one hole after choosing the direction of the pipe. Fixing the installation plate The following connection accessories are optional. If they are not supplied, you should obtain them before installing the air conditioner. Optional accessories Tools required for installation Insulated Assembly Pipe, O6.35mm (1) Insulated Assembly Pipe, O9.52mm (1) ..09.. Insulated Assembly Pipe, O12.70mm (1) ..12/18.. Insulated Assembly Pipe, O15.88mm (1) ..24.. PE T3 Foam Tube Insulation (1) Vinyl Tapes (2) Drain Plug (1) Rubber Legs (4) Pipe Clamps A (3) Pipe Clamps B (3) Cement Nails (6) M4 x 25 Tapped Screws (6) Drain Hose, length 2m (1) Putty 100g (1) • If these accessories are supplied, they will be in the accessory box. General Tools • Vacuum Pump(Backward flowing prevention) • Manifold Gauge • Stud Finder • Torque Wrench • Pipe Cutter • Reamer • Pipe Bender • Spirit Level • Screw Driver • Spanner • Drill • L Wrench • Measuring Tape Tools for test operations • Thermometer • Resistance Meter • Electroscope You can select the direction of the drain hose depending on where you want to install the indoor unit. Therefore before fixing the installation plate to a wall or a window frame, ...
Other models in this manual:Air Conditioner & Split Systems - AQ09TSBN (5.17 mb)
Air Conditioner & Split Systems - AQ09TSBX (5.17 mb)
Air Conditioner & Split Systems - AQ09UGFN (5.17 mb)
Air Conditioner & Split Systems - AQ09UGFX (5.17 mb)