|
manual abstract
IMPORTANT Before cleaning your air conditioner, ensure that you have switched off the breaker used for the unit. 1 Open the upper front grille by pulling the lower right and left tabs of the grille. 2 Pull air filters out of each tab of the grille. 3 Remove all dust on the air filters with a vacuum cleaner or brush. 4 When you finished, insert air filters by fixing it to each tab of the grille. 5 To close the front grille, fix it to hooks and push down the lower right and left tabs of the grille. 6 Clean the front grille with a damp cloth and mild detergent (do NOT use benzene, solvents or other chemicals). Note If you have not used the air conditioner for a long period of time, set the fan going for three to four hours to dry the inside of the air conditioner thoroughly. Front grille Air filter Body groove Body Front grille Hook Body To remove minute dust particles and odors, deodorizing and Bio filter are installed in the air conditioner. You should clean the filters every 3 months. 1 Open the upper front grille by pulling the lower right and left tabs of the grille. 2 Pull out the deodorizing and Bio filter. 3 Wash the filters with clean water, then dry them in the shade. 4 Insert the filters into the original position. Note You can change the position of filters with each other. 5 Close the front grille. Deodorizing Filter Bio Filter E-26 Temperature and Humidity Ranges .If the outdoor temperature is as low as 0°C, the heating capacity drops up to 70~80% depending on the operating condition. If you use the air conditioner in temperatures over 32°C (indoor temperature), the cooling capacity may drop. If you check the following tables, you can use your air conditioner more efficiently. If the air conditioner is used at... Then... Heating capacity The air conditioner may stop operating for the reason of protection. Low temperatures Water may leak and some malfunction may occur if the heat exchanger freezes. Protection mechanism Water may condense and drip from the surface of the indoor unit if you don’t use the air conditioner for an extended period of time. Operation Outdoor Temperature Indoor Temperature Indoor Humidity Heating 0°C to 24°C approx. 27°C or less - Cooling 21°C to 43°C approx. 16°C to 32°C approx. 80% or less Dehumidifying 18°C to 43°C approx. 16°C to 32°C approx. - Operating Recommendations When you use your air conditioner, it is recommended that you read the following: Topic Recommendation Heating capacity The heat pump inside the air conditioner absorbs heat from outside air and brings itindoors. If the temperature of the outside air drops, the air conditioner heats less. If the room is not warm enough, use an additional heating appliance. Warm air circulation The air conditioner circulates warm air to heat your room. It will take some time to warm the air in your room entirely after the air conditioner turns on. Therefore, turn the air conditioner on in advance. Frost When you select the Heat mode, frost may form in the outdoor unit due to low temperature and high humidity. If this happens: .The heating operation is stopped. .The air conditioner defrosts automatically for about 7 minutes. After about 7 minutes, the air conditioner starts operating again normally. High indoor and outdoor temperatures If both the indoor and outdoor temperatures are high when you select the Heat mode, the fan and the compressor of the outdoor unit may stop periodically. This is normal; wait until the air conditioner turns on again. Power failure If a power failure occurs when the air conditioner is operating, the air conditioner will turn off. When the power returns, the air conditioner will start up again automatically. Protection mechanism When the air conditioner is started immediately after being plugged in or stopped, the normal operation starts up after 3 minutes for the reason of protection. Temperature and Humidity Ranges .If the outdoor temperature is as low as 0°C, the heating capacity drops up to 70~80% depending on the operating condition. If you use the air conditioner in temperatures over 32°C (indoor temperature), the cooling capacity may drop. If you check the following tables, you can use your air conditioner more efficiently. If the air conditioner is used at... Then... Heating capacity The air conditioner may stop operating for the reason of protection. Low temperatures Water may leak and some malfunction may occur if the heat exchanger freezes. Protection mechanism Water may condense and drip from the surface of the indoor unit if you don’t use the air conditioner for an extended period of time. Operation Outdoor Temperature Indoor Temperature Indoor Humidity Heating 0°C to 24°C approx. 27°C or less - Cooling 21°C to 43°C approx. 16°C to 32°C approx. 80% or less Dehumidifying 18°C to 43°C approx. 16°C to 32°C approx. - Operating Recommendations When you use your air conditioner, it is recommended that you read the following: Topic Recommendation Heating capacity The heat pump inside th...
Other models in this manual:Air Conditioner & Split Systems - AQ09FAN (8.16 mb)
Air Conditioner & Split Systems - AQ09JWAN (8.16 mb)
Air Conditioner & Split Systems - AQ12FAN (8.16 mb)
Air Conditioner & Split Systems - AQ12FBN (8.16 mb)