|
manual abstract
Allow air to circulate around the unit without obstructions. 4. Start your air conditioner before outdoor air becomes hot/cold and uncomfortable. This avoids an initial period of discomfort while the unit is cooling or heating off the room. 5. When outdoor temperature is cool enough, use HIGH or LOW FAN only. This circulates indoor air, providing some cooling comfort, and utilizes less electricity than when operating on a cooling setting. Your RoomAir Conditioner was designed for easy installation in a single or double-hung window. NOTE: This unit is NOT designed for vertical (slider type) windows. CAUTION! ! To avoid installation/operating difficulties, read the instructions thoroughly. NOTE: Save the shipping carton and packing materials for future storage or transport of the unit. Please check the contents of the hardware kit against the corresponding model check list, prior to installation of the unit. See lists below.(Fig.A) 3/4 Screws (10) Top Channel(1) End Cap & Leveling Legs(2) Lock Washers(4) MountingBrackets(2) AngleBrackets(2) 1-1/2 x1/4 Bolts(4) Side Curtain RH(1) Side Curtain LH(1) Shutter Clamp(2) 1/4 Screws (23) Top Channel(1) Seal(1) Lock Washers(4) 1/4 Nuts(4) Mounting Brackets(2) Angle Brackets(2) Side Curtain RH(1) Side Curtain LH(1) Shutter Clamp(2) Fig. A Installation Hardware Gasket(10) NOTE: Surplus screw(s) for spare use. Foam (1) Double Adhering Seal(1) Bottom Channel(1) (For 15K to 24K models) (Factory-installed) Bottom Channel(1) (For 8K to 12K models) Tools Needed for Window Installation Screw drivers: Both Philips and flat head Power drill: 1/8 inch diameter drill bit Pencil Measuring tape Scissors Carpenters level 7 WAC 8-24 USER MAN FINAL 3/2/05 12:13 PM Page 10 INSTALLATION INSTRUCTIONS CAUTION! ! Because the compressor is located on the controls side of the unit (right side), this side will be heavier and more awkward to manipulate. Inadequate support on control side of the unit can result in personal injury and damage to your unit and property. Therefore, it is recommended to have someone assist you during the installation of this unit. E. Be certain the proper electrical outlet is within reach of the installation. Use only a single outlet circuit rated at proper current (see table 1 on page 4). All wiring should be in accordance with local and national electrical codes. F. Your unit was designed to evaporate condensation under normal conditions. However, under extreme humidity conditions, excess condensation may cause the basepan to overflow to the outside. The unit should be installed where condensation run-off cannot drip on pedestrians or neighboring properties. 1. Select the Best Location A. Your room air conditioner was designed to fit easily into a single or double hung window. However, since window designs vary, it may be necessary to make some modifications for safe and proper installation. B. Make sure window and frame is structurally sound and free from dry and rotted wood. C. For maximum efficiency, ...
Other models in this manual:Air Conditioner & Split Systems - AAW-08CM1FHUE (5.16 mb)
Air Conditioner & Split Systems - AAW-22CR1FHUE (5.16 mb)
Air Conditioner & Split Systems - AAW-24CM1FHUE (5.16 mb)
Air Conditioner & Split Systems - AAW-24CR1FHUE (5.16 mb)