manual abstract


Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb) Item Unit Power Source (Phase, Voltage, Cycle) o Single V 220 - 240 Hz 50 Input Power W Cooling; 965 (185 ~ 1140) Heating; 1320 (175 ~ 1770) Starting Current A 6.25 Running Current A Cooling; 4.60 - 4.25 Heating; 6.25 - 5.80 Maximum current A 8.70 Power Factor % Cooling; 95 - 95 Heating; 96 - 95 Power factor means total figure of compressor, indoor fan motor and outdoor fan motor. Power Cord Number of core — Length m — Thermostat Electronic Control Protection Device Electronic Control Note • Specifications are subject to change without notice for further improvement. 7 2.3. CS-E18GFEW-2 CU-E18GFE-2 ITEM UNIT INDOOR UNIT OUTDOOR UNIT Performance Test Condition ISO5151 C O O L I N G Capacity kW 5.00 (0.90 ~ 5.60) BTU/h 17100 (3100 ~ 19100) kcal/h 4300 (770 ~ 4820) EER W/W 3.23 (3.53 ~ 2.93) kcal/hW 2.77 (3.02 ~ 2.52) Noise Level dB (A) High 44, Low 36, QLo 32 High 47 Power level dB High 60, Low 52, QLo 48 High 60 H E A T I N G Capacity kW 5.80 (0.90 ~ 7.10) BTU/h 19800 (3100 ~ 24200) kcal/h 4990 (770 ~ 6110) COP W/W 3.63 (3.46 ~ 3.02) kcal/hW 3.12 (2.96 ~ 2.60) Noise Level dB (A) High 44, Low 36, QLo 32 High 48 Power level dB High 60, Low 52, QLo 48 High 61 Moisture Removal l/h 2.8 pt/h 5.9 Air Volume QLo m3/min (ft3/min) Cooling; 7.1 (250) Heating; 7.3 (259) — Lo m3/min (ft3/min) Cooling; 8.3 (291) Heating; 9.1 (322) — Me m3/min (ft3/min) Cooling; 9.6 (337) Heating; 11.1 (390) — Hi m3/min (ft3/min) Cooling; 11.0 (388) Heating; 13.0 (459) Cooling; 40.0 (1410) Heating; 40.0 (1410) SHi m3/min (ft3/min) Cooling; 11.6 (409) Heating; 13.6 (480) — Refrigeration Control Device — Expansion Valve Refrigeration Oil cm3 — RB68A (900) Refrigerant (R410A) g (oz) — 1.06k (37.4) Dimension Height mm (inch) 600 (23-5/8) 750 (29-17/32) Width mm (inch) 700 (27-9/16) 875 (34-15/32) Depth mm (inch) 210 (8-9/32) 345 (13-19/32) Net Weight kg (lbs) 14 (31) 49 (108) Pipe Diameter Gas mm (inch) 12.7 (1/2) Liquid mm (inch) 6.35 (1/4) Standard Length m (ft) 7.5 (24.6) Pipe Length Range m (ft) 3 (9.8) ~ 20 (65.6) Height Difference m (ft) 15 (49.2) Additional Gas Amount g/m (oz/ft) 20 (0.2) Refrigeration Charge Less m (ft) 10 (32.8) Drain Hose Inner Diameter mm 15 — Length mm 220 — Compressor Type — Hermetic Motor Motor Type — Brushless (4-pole) Rated Output W — 900 8 ITEM UNIT INDOOR UNIT OUTDOOR UNIT Fan Type Turbo Fan Propeller Fan Material ASG PP Motor Type Transistor (8-pole) Transistor (8-pole) Input Power W — 62.1 Output Power W 48 40 Fan Speed QLo (Cool/Heat) rpm 490 / 490 — Lo (Cool/Heat) rpm 570 / 610 — Me (Cool/Heat) rpm 660 / 740 — Hi (Cool/Heat) rpm 760 / 870 660 / - SHi (Cool/Heat) rpm 800 / 910 — Heat Exchanger Fin Material Aluminium (Pre Coat) Aluminium (Pre Coat) Fin Type Slit Fin Corrugated Fin Row x Stage x FPI 2 x 22 x 19 2 x 34 x 16 Size (W x H x L) mm 510 x 396 x 24 36.4 x 714 x 803.2 831.9 Air Filter Material PET — Type Honeycomb — 1. Cooling capacities are based on indoor temperature of 27°C Dry Bulb (80.6°F Dry Bulb), 19.0°C Wet Bulb (66.2°F Wet Bulb) and outdoor air temperature of 35°C Dry Bulb (95°F Dry Bulb), 24°C Wet Bulb (75.2°F Wet Bulb) 2. Heating capacities are based on indoor temperature of 20°C Dry Bulb (68°F Dry Bulb) and outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb) Item Unit Power Source (Phase, Voltage, Cycle) o Single V 220 - 240 Hz 50 Input Power W Cooling; 1550 (255 ~ 1910) Heating; 1600 (260 ~ 2350) Starting Current A 7.35 Running Current A Cooling; 7.20 - 6.90 Heating; 7.35 - 6.95 Maximum current A 10.5 Power Factor % Cooling; 98 - 94 Heating; 99 - 96 Power factor means total figure of compressor, indoor fan motor and outdoor fan motor. Power Cord Number of core — Length m — Thermostat Electronic Control Protection Device Electronic Control Note • Specifications are subject to change without notice for further improvement. 9 3 Location of Controls and Components 3.1. Indoor Unit 3.2. Outdoor Unit 3.3. Remote Control 10 4 Dimensions 4.1. Outdoor Unit 4.1.1. CU-E9GFE-2 CU-E12GFE-2 11 4.1.2. CU-E18GFE-2 12 5 Refrigeration Cycle Diagram 5.1. CS-E9GFEW-2 CU-E9GFE-2 CS-E12GFEW-2 CU-E12GFE-2 Model Piping size Rated Length (m) Max. Elevation (m) Min. Piping Length (m) Max. Piping Length (m) Additional Refrigerant (g/m) Gas Liquid E9GFE-1/E12GFE-1 3/8” 1/4” 7.5 5 3 15 20 If piping length is over rated length, additional refrigerant should be added as shown in the table. 13 5.2. CS-E18GFEW-2 CU-E18GFE-2 Model Piping size Rated Length (m) Max. Elevation (m) Min. Piping Length (m) Max. Piping Length (m) Additional Refrigerant (g/m) Gas Liquid E18GFE-1 1/2” 1/4” 7.5 15 3 20 20 If piping length is over rated length, additional refrigerant should be added as shown in the table. 14 6 Wiring Connection Diagram 6.1. Outdoor Unit 6.1.1. CU-E9GFE-...

Other models in this manual:
Air Conditioner & Split Systems - CS-E18GFEW-2 (3.81 mb)
Air Conditioner & Split Systems - CS-E12GFEW-2 (3.81 mb)
Air Conditioner & Split Systems - CS-E9GFEW-2 (3.81 mb)
Air Conditioner & Split Systems - CU-3E18EBE (3.81 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category