The waste battery shall be disposed properly. 7. The indoor unit installation height is at least 2.5m. Rated Maximum MinimumCooling Indoor DB C 27 32 18WB C 19 23 14outdoor DB C 35 43 10WB C 24 26 6Heating Indoor DB C 20 27 15WB C 14.5 ---outdoor DB C 7 24 -15WB C 6 18 - 2 3 Main Points of Operation Operation of Air Conditioner When the environmental humidity is great, water maybe dripped from the air outlet in cooling or drying mode. 3-minute Protection Function If restart the unit immediately after stopping, the compressor will start only 3 minutes later to protect the machine. Variation of Fan Speed If fan speed in auto mode, it will automatically lower when the room temperature close to the setting temperature in cooling mode. In heating mode,the compressor stops when the room temperature at setting temperature and fan turns into low speed or stops. In Dry mode,fan speed will be automatically varied. Remote Control: There is a telecommunication interface for remote control on the control panel of the indoor unit. After the peripheral equipment have been installed in accordance with the instruction manual of the selected remote control detector, the air conditioner will be computerized and controlled from a faraway place. 4 Main Points of Operation Prevent Cool Air Blowing Off In heating mode,the indoor fan will not run immediately after the unit starts to prevent the cool air blowing off. Defrosting Function In heating mode, when frost formed on the outdoor heat exchanger, the air conditioner will automatically defrost a few minutes. During defrosting, both indoor and outdoor fan will stop running. When defrosting finished, air conditioner will automatically back to running. Hints The air conditioner absorbs heat form outside and releases inside when in heating mode, therefore the outside environmental temperature will affect heating effects. Power Failure Compensation(to be applied for a necessary situation): After the power failure compensation is set, if power failure suddenly occurs while the air conditioner is working,it will resume the previous working state when the power is supplied again. Setting Method: When the remote controller is on (excluding timer mode and fan mode),press the isleepingi button on the remote controller 10 times within 5 seconds,and after the buzzer rings 4 times, the air conditioner will enter the state of power failure compenstation. Cancel Method:Press the isleepingi button on the remote controller 10 times within 5 seconds, and after the buzzer rings 2 times, the power failure compensation mode will be cancelled. Note: When a power failure suddenly occurs during the air conditioner is working after the power failure compensation is set,if the air conditioner will not be used for a long time, please cut off the power supply to prevent its operation from being resumed after the power is supplied again, or press the i Switch On/Off i button after the power comes again. Defrosting Running Wait a minute 5 Parts and Functions Swing louver (Air flow direction can be adjusted by using the SWING button on the remote controller) Air Inlet Grille Air Filter (Inside of the Inlet Grille) Operating Control Panel Safety Cautions Carefully read the following information in order to operate the air conditioner correctly. Below are listed four kinds of Safety Cautions and Suggestions: WARNING: Incorrect operations may result in severe consequences of death or serious injures. CAUTION : Incorrect operations may result in injures or machine damages; in some cases may cause serious consequences. : It must be strictly prohibited where marked with i Prohibited i, otherwise may result in machine damages or endanger the useripersonal safety. INSTRUCTION: This information can ensure the correct operation of the machine. Be sure to conform with the following important Safety Cautions. The Safety Cautions should be at hand so that they can be checked at any time when needed. If the air conditoner is transferred to the new user, this manual should be as well transferred to the new user. WARNING If any abnormal phenomena are found (e.g. Call the dealer to take measures to prevent the smell of firing),please cut off the power supply refrigerant from leaking. immediately, and contact the dealer to find outi The leaked refrigerant over certain density may the handling method. cause oxygen deficient.If the air conditioner is installed in a small room be sure to take measure In such case,to continue using in order to prevent suffocation accident even in Switchthe air conditioner will damage case of refrigerant leakage off the conditioner,and may cause electrical shock or fire hazard. When air conditioner is removed and reinstalled dealer should be responsible for them. Incorrect installation may cause water leaking, When need maintenance and electrical shock and fire hazard. repair,call dealer to handle it. Donit dismantle the outlet of the outdoor unit. Incorrect maintenance and repair may cause water l...
Other models in this manual:Air Conditioner & Split Systems - AB092XCERA (895.9 kb)
Air Conditioner & Split Systems - AB142XCERA (895.9 kb)
Air Conditioner & Split Systems - AB122XCERA (895.9 kb)