Login:
Votes - 3, Average rating: 4 ( )

User manual Haier, model AB422ACERA

Manafacture: Haier
File size: 877.15 kb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


1)The fuse or breaker often shuts down. 2)Water drops off during cooling or drying operation. 3)There is an irregularity in operation or abnormal sound that is audible. 15 When Trouble Happens Error display ( For ERA series ) For remotetype, flashtimesFailure descriptionReasonRemarks 1Indoor ambient temp. sensor failureSensor broken down or short circuit for more than 2m continuously 2Indoor coil temp. sensor failureSensor broken down or short circuit for more than 2m continuously 3Outdoor ambient temp. sensor failureSensor broken down or short circuit for more than 2m continuously 4Outdoor coil temp. sensor failure (compressordischarging temp. sensor) Sensor broken down or short circuit for more than 2m continuously 5Over-current protectionCT check abnormal 3 times in 30m 6High pressure abnormalHigh pressure switch acts 3 times in 30m 7Power supply abnormalFault phase, short of phase, out of balance greatly 8Communication between wiredcontroller and indoor abnormalCommunication abnormal for more than 4m continuously 9Communication between indoor and outdoor abnormalCommunication abnormal for more than 4m continuously 10Drainage system abnormalFloat switch broken down for more than 25m continuously 11Outside alarm signal inputOutside signal broken down for more than 10s 12Gas pipe temp. sensor abnormalSensor broken down or short circuit for more than 2m continuously 13Temperature protection malfunctionSolenoid valve act incorrectly 3 times continuously 14Discharging temp. sensor abnormalSensor broken down or short circuit for more than 2m continuously 15EEPROM abnormalEEPROM data missing 16Pressure abnormal(low pressure) Low pressure switch acts in normal running 17Compressor overheatThe discharging temperature is higher than 120degreeResumable iflower than 100degree 18Abnormal modeIndoor operation mode is different with the running indoor unit. 19Outdoor coil B(suction temp sensor-for MRV II) Sensor broken down or short circuit for 20Outdoor discharging B(oil temp sensor-for MRV II) Sensor broken down or short circuit 21 SPDU module temperature protection Spdu module temperature is too shows resumable fault, 16 When Trouble Happens Error display ( For EAA series ) For remotetype, flashtimesFailure descriptionReasonRemarks 1Indoor ambient temp. sensor failureSensor broken down or short circuit for more than 2m continuously 2Indoor coil temp. sensor failureSensor broken down or short circuit for more than 2m continuously 3Outdoor ambient temp. sensor failureSensor broken down or short circuit for more than 2m continuously 4Outdoor coil temp. sensor failure (compressordischarging temp. sensor) Sensor broken down or short circuit for more than 2m continuously 5Over-current protectionCT check abnormal 3 times in 30m 6High pressure abnormalHigh pressure switch acts 3 times in 30m 7Power supply abnormalFault phase, short of phase, out of balance greatly 8Communication between wiredcontroller and indoor abnormalCommunication abnormal for more than 4m continuously 9Communication between indoor and outdoor abnormalCommunication abnormal for more than 4m continuously 10Drainage system abnormalFloat switch broken down for more than 25m continuously 11Outside alarm signal inputOutside signal broken down for more than 10s 12Gas pipe temp. sensor abnormalSensor broken down or short circuit for more than 2m continuously 13Temperature protection malfunctionSolenoid valve act incorrectly 3 times continuously 14Discharging temp. sensor abnormalSensor broken down or short circuit for more than 2m continuously 15EEPROM abnormalEEPROM data missing 16Pressure abnormal(low pressure) Low pressure switch acts in normal running 17Compressor overheatThe discharging temperature is higher than 120degreeResumable iflower than 100degree 18Abnormal modeIndoor operation mode is different with the running indoor unit. 19Outdoor coil B(suction temp sensor-for MRV II) Sensor broken down or short circuit for 20 Outdoor discharging B(oil temp sensor-for MRV II) Sensor broken down or short circuit shows resumable fault, * 17 Customer Need-to-know Customer Need-to-know Please install the air conditioner according to the requirements specified in this manual to ensure the air conditioner work well. Be careful not to scratch the surface of the case during moving the air conditioner. Please keep the installation manual for future reference when maintenance and changing installation place. After installation ,please use the air conditioner according to the specification in the operation manual. Using Directions Adjust suitable airflow direction Avoid direct sunlight and airflow Keep the proper indoor temperature. Too cool or hot is not good for your health. Furthermore,it will result in excessive consumption of electric power. Optimal temperature Effectively use timer. Using TIMER mode, you can make the room temperature reach a suitable temperature when you wake up or back home. 18 Installation Procedure CAUTIONS: To ensure proper installation, read ...

Other models in this manual:
Air Conditioner & Split Systems - AB142ACEAA (877.15 kb)
Air Conditioner & Split Systems - AB142ACERA (877.15 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category