Login:
Votes - 3, Average rating: 3.7 ( )

User manual Panasonic, model HQ2101SH

Manafacture: Panasonic
File size: 2.95 mb
File name: HQ2101SH.PDF
Language of manual:enes
Free link for this manual available at the bottom of the page



manual abstract


PLACE FRONT INTAKE GRILLE OVER THE FRONT GRILLE Slide the front intake grille slightly to the right to reattach the tabs and then push it down to close tight. Lift up about 90°. a d c OFF/ON OPERATION TEMP/TIMER COOL FAN HIGH MED LOW MODE FAN SPEED SET TIMER SET/ CANCEL AIR SWING ECONOMY hr °F Wireless Remote Control OFF LOW COOL LOW FAN HIGH FAN HIGH COOL THERMOSTAT 10 9 8 7 5 6 4 3 1 2 AIR SWING ON OFF 2 AIR CONDITIONER INSTALLATION 1 Air inlet louver 4 Air filter 2 Cabinet 5 Front intake grille 3 Power cord 6 Front grille 7 Vertical airflow direction vane (Airflow direction adjustment up-down). The vertical airflow direction vane is controlled by rotating the horizontal vane forward or backward. 3 PART IDENTIFICATION MAIN UNIT 8 Ventilation lever The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions. When fresh air is necessary in the room, set the ventilation lever to the OPEN position. The damper is opened and room air is drawn out. 1 2 3 4 5 6 8 7 9 a b c 1 Remove the rubber plug and slide the chassis out from the cabinet. Remove the rubber plug 2 Install the optional drain pan (part no. CWH40175). Screws INTERNAL VIEW Drain pan (optional) Install the drain pan at the right corner of the cabinet using 2 screws (part no. CWG86C733). 3 Connect a drain hose (optional). Fit the drain hose to the drain pan. EXTERNAL VIEW Under-side view with drain pan and hose in place. Drain hose (not included) 4 Slide the chassis back into the cabinet. Reinstall the cabinet to chassis by using screws. NOTE The drain pan (part no. CWH40175) can be obtained from nearest servicenter. NOTE Drain hose or tubing can be purchased locally to satisfy your particular needs. THERMOSTAT 10 9 8 7 5 6 4 3 1 2 HIGH OFF COOL LOW COOL LOW FAN HIGH FAN AIR SWING ON OFF TH AIR SWING ON OFF OFF LOW COOL LOW FAN HIGH FAN HIGH COOL THERMOSTAT 10 9 8 7 65 4 3 1 2 AIR SWING ON OFF 9 Main control panel a Air Swing Switch OFF Stops the operation of Air Swing. ON Air Swing is in operation. (Only for LOW COOL, MED COOL, HIGH COOL and ECONOMY operation.) b Main Control Knob Stops all operation Low fan speed operation (without cooling) High fan speed operation (without cooling) Low fan speed with cooling operation High fan speed with cooling operation c Thermostat Control Knob For decreased cooling For increased cooling HOW TO ATTACH THE DRAIN PAN (OPTIONAL) 4 AIR CONDITIONER OPERA TION 5 PRODUCT SPECIFICATIONS 6 ENERGY SAVING HINTS 4AIR CONDITIONER OPERATION 5 PRODUCT SPECIFICATIONS 6 ENERGY SAVING HINTS THERMOSTAT 10 9 8 7 65 4 3 1 2 1 Open the control panel cover. 2 Power Supply. Switch off the breaker and set the main control knob to the OFF position; confirm that the power supply cord is connected to a proper AC outlet. < 115V, 60Hz > Thermostat Control Knob. For a room that is too warm, set the control knob to a clockwise direction. • If the room is too cool, set the control knob to a counter clockwise direction. * Note : Usually 6~7 is the recommended setting position. NOTE : Recommended setting 4 Air Swing Switch. (Airflow direction adjustment Side-to-Side) To obtain a fix airflow direction, set the air swing switch to “ON” for the vanes to swing from side to side until the desired flow direction is reached, then switch it to “OFF”. For continuous side-to-side air circulation, set the air swing switch to “ON”. AIR SWING ONOFF OFF LOWCOOL LOWFAN HIGHFANHIGHCOOL THERMOSTAT 10 9 8 7 654 3 1 2 AIR SWINGOFF Model HQ-2101SH HQ-2121SH COOLING CAPACITY Btu/h 10,000 11,500 ELECTRICAL RATING Phase Single + Frequency Voltage (Hz) (V) 60 115 + + Current (Amps) 8.7 9.8 Input (W) 980 1120 EER (Btu/W.h) 10.2 + MOISTURE REMOVAL (Pints/h) 2.5 3.0 ROOM AIR CIRCULATION (Cf/min) 320 330 DIMENSIONS Height cm (inches) 37.5 (14-25/32.) + Width cm (inches) 56 (22-1/16.) + Depth cm (inches) 60.6 (23-27/32.) + NET WEIGHT kg (lb) 35 (77) + GROSS WEIGHT kg (lb) 39 (86) + NOISE LEVEL Indoor (Hi/Lo) dB (A) 50/46 51/47 Outdoor (Hi/Lo) dB (A) 57/54 58/55 * Specifications are subject to change without notice for further improvement. ENERGY SAVING HINTS • This may affect your well-being as well as increase power consumption. • The cooling capacity of the room air conditioner must match the room size for efficient and satisfactory operation. • Prevent hot air from entering and cool air from escaping. • Ensure that curtains and drapes are always closed to keep out direct sunlight during cooling operation. Avoid heat. • Clean the air filter every 2 weeks. Dirty filters may reduce cooling efficiency. 7CARE AND MAINTENANCE8 BEFORE CALLING FOR SERVICE 7CARE AND MAINTENANCE8 BEFORE CALLING FOR SERVICE Always turn off the air conditioner and the main power supply before clean the unit. Switch off the power supply if the unit is not going to be used for a long period of time. CAUTION CARE AND MAINTENANCE • Clean the cabinet, front grille with a mild soap or detergent and lukewarm water. • The front intake grille can be easily removed for ...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category