(Fig. 1) 2. Wash the air filter in warm 104°F (40°C) water. Be sure to shake off all the water before replacing the filter. • CLEANING THE AIR CONDITIONER The front grille and inlet grille may be wiped with a cloth dampened in a mild detergent solution. (Fig. 2) The cabinet may be washed with mild soap or detergent and lukewarm water, then polished with Liquid Wax for Appliances. To ensure continued peak efficiency, the condenser coiis(outside of unit) should be checked periodically and cleaned if clogged with soot or dirt from the atmosphere. • HOW TO REMOVE THE FRONT GRILLE 1. Remove the thermostat knob and the operation knob by pulling. 2. Remove the screw securing the front grille. (Fig. 3) 3. Push the grille up from the bottom and pull the top of the grille away from the case as the top tabs lift out of their slots. (Fig. 4) Do not force or open far (about CO CM Features and Installation Learning parts name prior to installation will help you understand the installation procedure. —i Features 1 Q 1. CABINET 2. HORIZONTAL AIR DEFLECTOR 3. COOL AIR DISCHARGE 4. FRONT GRILLE 5. INLET GRILLE 6. AIR FILTER 7. KNOBS 8. AIR INTAKE 9. UPPER GUIDE 0 Window Requirements NOTE: All supporting parts should be secured to firm wood, masonry, or metal. 1. This unit is designed for installation in standard double hung windows with actual opening widths of 22" to 36". The upper and lower sash must open sufficiently to allow a clear vertical opening of 13" from the bottom of the sash to the window stool. 2.If storm window presents interference, fasten a 2" wide wood strip to the inner window sill across the full width of the sill. The wood strip should be thick enough to raise the height of the window sill so that the unit can be installed without interference by the storm window frame. See Fig. 5-2. Top of wood strip should be approximately 3/4" higher than the storm window frame (STORM WINDOW FRAME) or wood strip (OUTDOORS) to help condensation to drain properly to the outside. 3. Install a second wood strip (approximately 6" long by 11/2" wide and same thickness as first strip) in the center of the outer sill flush against the back off the inner sill. This will raise the L bracket as shown Fig. 5-2. 4. If the distance between STORM WINDOW FRAME and WOOD STRIP MOUNTED ON TOP OF INNER SILL is more than 1", two of wood strips are not necessary. Installation HARDWARE TYPE A: 11EA (SHORT SCREW) TYPE B: 4EA (WOOD SCREW) TYPE C: 3EA ("L" BRACKET) DRAIN PIPE TYPED: 1EA (SEAL STRIP) (Adhesive backed) TYPEE: 1EA (SASH SEAL) (Not adhesive backed) TYPE F: 2EA (GUIDE PANEL) A. BEFORE INSTALLATION 1. Insert the guide panels into the guides of the air conditioner. Fasten the curtains to the unit with screws (TYPE A) as shown Fig. 6. 2. Cut the adhesive-backed seal strip (TYPE D) to the window width. Remove the backing from the seal strip and attach the seal strip to the underside of the bottom window. (Fig. 7) B. NOW START INSTALLATION 1. LOCATING UNITIN WINDOW Open the window and mark the center line on the center of the inner sill, as shown in Fig. 8. 2. ATTACH "L" BRACKET a. Install the "L"' brackets behind the inner window sill, with the short side of bracket as shown. Use the 2 screws (TYPE A) provided. b. The bracket helps to hold unit securely in place. Be sure to place bracket edge flush against back of inner sill. See Fig. 9. During the following step, hold unit firmly until window sash is lowered to top channel behind side panel frames. Personal injury or properly damage may result if unit falls from window. 3. INSTALL THE AIR CONDITIONER IN THE WINDOW a. Carefully lift the air conditioner and slide it into the open window. Make sure the bottom guide of the air conditioner drops into the notches of the "L" bracket. See Fig. 9. IMPORTANT: When the air conditioner drops into the nL" bracket, the air conditioner will be centered in window opening as shown in Fig. 10. © INNER SILL OUTER SILL I TYPEA INSIDE .CENTER LINE SHORT SIDE > OUTSIDE Fig. 9 *L" BRACKET pa . fc= BÎ2s=ïIÎ5SS Fig. 10 CENTER LINE b. While steadying the air conditioner, carefully bring the window sash down behind the upper guide of the air conditioner, as shown in Fig. 11. 4. SECURE THE GUIDE PANELS Extend the guide panels (TYPE F) to fill the window opening using 4 screws (TYPE B) to secure them, as shown in Fig. 12. 5. INSTALL THE SASH SEAL AND SASH LOCK a. Cut the sash seal (TYPE E) to the window width. Stuff the sash seal between the glass and the window to prevent air and insects from getting into the room, as shown in Fig. 12. b. Fasten the "L" bracket using a (TYPE A) screw, as shown in Fig. 12. 6. Window installation of room air conditioner is now completed. See ELECTRICAL DATA for attaching power cord to electricai outlet. C. HOW TO SECURE THE DRAIN PIPE In humid weather, excess water may cause the BASE PAN to overflow. To drain the water, remove the DRAIN CAP and secu...
|