User manual Goldstar, model M5203L

Manafacture: Goldstar
File size: 1.34 mb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


output? • Check the Main P.W.B pattern. • Exchange the Trans. NO YES • Exchange D02D~D05D. • Exchange IC01D. NO Is output Voltage of IC02D • Exchange IC02D. DC 5V? YES Is the reset circuit all right? (The No.16 of Micom is 5V.) NO • Exchange IC01A. YES Is the connection between Main and Display all right? NO • Connect connector exactly. YES NO Is the voltage No.20 of Micom DC 5V? • Check the P.W.B pattern. YES Exchange Main P.W.B Ass'y. —20— Possible Trouble 2 • The compressor does not operate. Is Temp. setting set lower than Room Temp.-0.5°C? NO YES • Set the Temp. setting to higher Temp. NO NONO YES YES YES • Check the RY-COMP. • Exchange IC01M. • Wait 3 Minutes • Check the wiring Diagram. Is the voltage No.11 of IC01M 0V? Is the Unit for 3 minutesIs the voltage N0.6 of delay?IC01M DC 5V? • Exchange MAIN P.W.B Ass'y. Possible Trouble 3 • The compressor always operate. Is the wire connection of RY-COMP all right? NO YES • Connect LEAD Wire to RY-COMP again. • Check the RY-COMP. Possible Trouble 4 • Fan does not operate. • Exchange IC01M. • Exchange IC01M. Is the voltage NO.2 or 4 of IC01M DC 5V? Is the voltage NO.13 or 15 of IC01M 0V? NO NO YES YES • Check the RY-Hi or RY-Lo. • Check the wiring diagram. —21— Possible Trouble 5 • Romote controller does not operate. (only for M-5400, M-6000, M-7000) Is the voltage of Battery about over 2.3V? Is the connection of CN-DISP2 all right? Is the voltage No.10 of CN-DISP2 on Main P.W.B Ass'y DC 5V? • Exchange the battery. • Check the P.W.B pattern. • Connect connector to CN-DISP2 exactly. NO NO NO YES YES YES • Exchange Receiver Ass'y. Possible Trouble 6 NO NO NO YES YES Is the IC01G all right? Is the connection of CN-DISP2 all right? • It displays abnormally on Display P.W.B Ass'y. • Exchange IC01G. • Connect connector to CN-DISP2 exactly. Does the Q12G, Q13G, Q14G operate normally on main P.W.B Ass'y? NO YES • Exchange Q12G, Q13G, Q14G • Exchange the display P.W.B Ass'y. —22— ROOM AIR CONDITIONER VOLTAGE LIMITS NAME PLATE RATING MINIMUM MAXIMUM 115V ± 10% 103.5V 126.5V COMPLAINT CAUSE REMEDY Fan motor will not run. No power Check voltage at outlet. Correct if none. Power supply cord Check voltage to rotary switch. If none, check power supply cord. Replace cord if circuit is open. Rotary switch Check switch continuity. Refer to wiring diagram for terminal identification. Replace switch if defective. Wire disconnected or connection loose Connect wire. Refer to wiring diagram for terminal identification. Repair or replace loose terminal. Capacitor (Discharge capacitor before testing.) Test capacitor. Replace if not within ±10% of manufacturer's rating. Replace if shorted, open, or damaged. Will not rotate Fan blade hitting shroud or blower wheel hitting scroll. Re-align assembly. Units using slinger ring condenser fans must have 0.22~0.25 inch clearance to the base. If necessary, shim up the bottom of the fan motor with mounting screw(s). Check fan motor bearings; if motor shaft will not rotate, replace the motor. Fan motor runs. Revolves on overload Check voltage. See limits on this page. If not within limits, call an electrician. Test capacitor. Check bearings. Does the fan blade rotate freely? If not, replace fan motor. Pay attention to any change from high speed to low speed. If the speed does not change, replace the motor. —23— COMPLAINT CAUSE REMEDY Fan motor noise. Fan If cracked, out of balance, or partially missing, replace it. Blower If cracked, out of balance, or partially missing, replace it. Loose set screw Tighten it. Worn bearings If knocking sounds continue when running or loose, replace the motor. If the motor hums or noise appears to be internal while running, replace motor. Compressor will not run, fan motor runs. Voltage Check voltage. See the limits on the preceding page. If not within limits, call an electrician. Wiring Check the wire connections; if loose, repair or replace the terminal. If the wires are disconnected, refer to wiring diagram for identification, and replace the wires. Check the wire connections; If not according to the wiring diagram, correct the connections. Thermistor Check the TEMP control. If not at the lowest number, set TEMP control to this setting and restart the unit. Check the continuity of the thermistor. Replace the thermistor if the circuit is open. Capacitor (discharge capacitor before servicing.) Check the capacitor. Replace if not within ±10% of manufacturer’s rating, replace if shorted, open, or damaged. Compressor Check the compressor for open circuit or ground. If open or grounded, replace the compressor. Overload Check the compressor overload if externally mounted. Replace if open. (If the compressor temperature is high, remove the overload, cool, and retest.) Compressor cycles on overload. Voltage Check the voltage. See the limits on the preceding page. If voltage is not within these limits, call an electrician. Overload Check overload, if externally mounted. Replace if open. (If the compressor temperature is...

Other models in this manual:
Air Conditioner & Split Systems - M5203R (1.34 mb)
Air Conditioner & Split Systems - M6003R (1.34 mb)
Air Conditioner & Split Systems - WM-6011 (1.34 mb)
Air Conditioner & Split Systems - LWC061JGMK1 (1.34 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category