Login:
Votes - 5, Average rating: 3.4 ( )

User manual Hisense Group, model KF 346GWE

Manafacture: Hisense Group
File size: 204.62 kb
File name: ac2bb871-235f-478c-9d5f-f49f83927292.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


)) : High fan speed. ) :Medium fan speed. :Low fan speed. 1 HR TIMER button (1-HOUR OFF TIMER) ■jjajE) :When you press this button, regardless of whether the unit is operating or stopping, the unit operates for one hour and then shuts down. ACL button Puts the remote control unit into pre-operation status. Always press this button after replacing the batteries. A/C SENSOR button NOTE When you press this button (use a small-tipped object such as a ballpoint pen), the mark will appear at the display. And the room temperature is detected by the sensor which is built into the indoor unit and the air conditioner is controlled accordingly. If the remote control is located near a heat source, such as a space heater or indirect sunlight, press the A/C SENSOR button to switch to the sensor in the indoor unit. Automatic switching between cooling and heating This unit automatically switches between cooling operation and heating operation according to the difference between the room temperature and the set temperature. NOTE The remote control unit sends the temperature signal to the air conditioner regularly at three minute intervals. If the signal from the remote control unit stops for more than ten minutes due to the loss of the remote control unit or other trouble, the air conditioner will switch to the temperature sensor which is built into the indoor unit and control the room temperature. In these cases, the temperature around the remote control unit may differ from the temperature detected at the air conditioner,s position. 7 • Operation Guide HOW TO INSTALL BATTERIES 1. Slide the cover in the direction indicated by the arrow and remove it. 2. Install two AAA alkaline batteries. Make sure the batteries point in the direction marked in the battery compartment. 3. Use a thin object such as the tip of a pen to press the ACL button. A NOTE © Replace the batteries when the remote control unit's display fails to light, or when the remote control unit cannot be used to change the air conditioners settings. Use two fresh leak-proof type-AAA alkaline batteries. In replacing batteries, follow the instructions as mentioned in the subsection How to install Batteries . If you do not use the remote control unit more than 1 month, take out the batteries. HOW TO USE THE REMOTE CONTROL UNIT When using the remote control unit, always point the unit's transmitter head directly at the air conditioner's receiver. REMOTE CONTROL UNIT INSTALLATION POSITION To ensure that the air conditioner operates correctly, DO NOT install the remote control unit in the following places: DO NOT * In direct sunlight I Behind a curtain or other places where it is covered I More than 8 meters away from the air conditioner ft In the path of the air conditioner's airstream I Where it may become extremely hot or cold I Where it may be subject to electrical or magnetic noise ) Where there is an obstacle between the remote control unit and the air conditioner 8 • Operation with the Remote Control Unit(continued) NOTE Check that the circuit breaker on the power panel is turned on and that the operation selector of the indoor unit is in the ON position. If the automatic operation settings of the unit do not meet your needs, press the setting buttons as described below and change the settings as desired. STEP 1 Press the MODE selector button and select the desired mode. For dehumidifying operation -► For cooling operation -► ^ For automatic operation ► (ffi) For fan operation -► gg STEP 2 To start the air conditioner, press the ON/OFF operation button. STEP 3 Press the TEMP setting button to change the temperature setting to the desired temperature . Adjustable temperature range: 30°C max. 16°C min. STEP 4 Set the FAN SPEED selector button to choose the fan speed you want. If the fan speed is set to © M (Automatic), the fan speed switches automatically, according to the difference between the actual room temperature and the set temperature. /|\ NOTE / 1 \ STEP 5 Press the FLAP button and set the airflow direction as desired. To stop the air conditioner, press the ON/OFF operation button again. 9 • Adjusting the Fan Speed A. Automatic Simply set the FAN SPEED selector to the © X position. A microcomputer in the air conditioner automatically controls the fan speed when the ® M mode is selected. When the air conditioner starts operating, the difference between the room temperature (RT) and the set temperature (T) is detected by the microcomputer which then automatically switches the fan speed to the most suitable level. Cooling mode: When difference between room temperatureand set temperature is FAN SPEED RT > T+3C High T+3C > RT > T+1C Medium RT< T+1C Low Mild drying mode: When difference between room temperature and set temperature is FAN SPEED RT > T+5C High T+5C> RT > T+3C Medium Rt


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category