|
User manual Hisense Group, model KF-5002GWE
Manafacture: Hisense Group File size: 729.42 kb File name: bb12a835-2e9c-485f-a373-ec62caab3454.pdf
Language of manual:
|
|
|
|
Free link for this manual available at the bottom of the page
manual abstract
l\ CAUTION: Operations displaying this symbol may result in serious injury. A. Instructions for installation B. Instructions for operation Installation only by authorized professionals through local distributors. Attention should be paid to power source, supply capacity, electrical wire or sockets. ' Never install the appliance in an area near inflammable gas. Install a correctly rated circuit breaker. The appliance must be earthed. Never earth the appliance to a gas or water pipe, lighting rod or phone wire. Correctly install tubes to avoid water leakage. • Do not sit directly in the cold air stream from the appliance, or set excessively low operation temperature. 1 Connect the appliance, using a separate cable and plug, to a dedicated socket with a capacity not less than 16A. Don't insert articles into the air inlet and keep children away from the appliance. Use the correctly rated electrical cable and protect from damage or heat sources. 2 Safety Notice Avoid unnecessarily plugging and unplugging the appliance. Be sure that the power plug is clean and completely inserted to the socket. The appliance must only be used for room air conditioning. Never operate the appliance with wet hand. Keep plants or pets away from the air source. Do not clean the appliance by washing with water. Hold the plug, not the wire, when unplugging the appliance. • Do not let the appliance under heavy load. 3 Safety Notice Keep the room well ventilated, especially in rooms where burners are used. Do not place other electrical appliance under the air conditioner. Disconnect the appliance when cleaning. Unplug the appliance when operation of the appliance stops. Make sure that fan stops before cleaning. Unplug the appliance in the event of abnormal operation and contact a distributor or the after-sales service for repair. Keep gas burners away from moving air from the appliance. Only qualified professionals should move the appliance for reinstallation. Contact the distributor or after-sales service for assistance. • Unplug the appliance when operation is suspended for long periods. • Only qualified professionals should repair the appliance. Contact the distributor or after-sales service for assistance. • Regularly check the securing bolts and support rack of the outdoor unit. 4 Components Introduction INDOOR UNIT Air filter Air fresh filter Indoor umt: s^sor^ns^^ OUTDOOR UNIT 5 Components Introduction INDOOR UNIT DISPLAY PANEL POWER o TIMER HI-POWER o OPERATING Each part stands for: 1. Power indicator illuminating means the appliance in operating condition. 2. Timer indicator illuminating means the appliance in timer or sleep condition 3. Operating indicator illuminating means the compressor in work condition. 4. Hi-power indicator illuminating means the appliance in hi-power condition. INDOOR UNIT SWITCH PANEL Indoor unit switch panel is under the front cover, it can be used while remote control unit is bad or losing. 6 Components Introduction REMOTE CONTROL UNIT Sensor Testing the ambient temperature of the remote control unit LCD - Displaying the running condition. Hi-power running button- Sleep button Press the button, the appliance enter sleep mode. Flap- Up-down adjustment Timer on/off button Setting the time of appliance on/off. Set/cancel timer button- Set or cancel the time of appliance on/off. A/C sensor button Press the button if the remote control unit is liable to be affected by the heat resource, such as electric blanket, radiator or sunlight, this will use the sensor of indoor unit, the symbol will appear on the LCD. .0$, æ l T.SETTINt DC JLl If ® © i i HOUR [Off©] ® 9 h© SLEEP FLAP C FAN/MUT CD CLR ' MODE V1 OFF© Transmitter Transmitting signals to the indoor unit, the symbol « will appear on the top of LCD. On/Off button Press the button to run, press again to cease. Temperature setting button Press the button marked " k "or " k " to increase or decrease the temperature. Mode selection button Auto i Fan dehumidification cooling -Fan speed selection button Reset button Press the button after batteries are loaded and indication appears on LCD. Sliding cover Battery compartment COMMONSENSE • Remove the batteries in the remote control unit when it is not used for a long period. • Replace the batteries when the indication on the LCD of the remote control unit is faint, or the remote control unit cannot be set or operated. • Properly dispose of used batteries. • Keep the remote control unit away from cold or hot air, sunlight or heat sources. • Contact the local distributor if the receiver in the appliance does not work in a room illuminated by fluorescent tubes. • Remote control unit must be used within its effective range or the timer and the temperature control will not function properly. • Control will fail if two of the same model appliances are installed in the same room. i If the remote control unit is ...
|