Take this into account! Rule of thumb, in average sunshine conditions and no presence of other heat sources: 35 BTU/h per square foot (thus 18000 BTU/h (5.1 kW) cooling capacity suits a ~515 ft2 (~50 m2) room). 125 BTU/ft2.h Attention: Make sure to have the professional after-sales service person of our company or the authorized dealer to instal the units. • The units may not be installed in places where there might be leakage of combustible gases: fire hazard. • Make sure that an earth leakage circuit breaker is installed. • Check whether the connection of wires between indoor and outdoor unit is not loose. • Make sure that the air conditioner is properly earthed. • Check the supporting structures for proper strength to carry the weight plus a safety margin. 11 Point of attention for the installation of electric components • HACR type breaker should be utilized along with proper installation. • Be sure to use the applicable voltage and cables or wires for the unit to be installed, before making the connections. • Read the prompts at the terminal board for wiring. Make sure the wiring is done correctly. • Pay attention to the poles of the signal terminal and connect the terminals to match the identification numbers. • The connecting wires and the breaker are not supplied. The specification is 14 AWG, VW-1 (or THHW), copper core and 194 °F (90 °C). Their set screw diameter is 4 mm. The power source is 230 V, 60Hz, 1 phase. Minimum circuit ampacity of the wiring system is 20 A. When the wiring connections are wrong, the compressor will not work. CONNECTION OF THE WIRES OF THE OUTDOOR UNIT • The earth wire must Outdoor unit be connected to the indoor unit and the outdoor unit. Breaker • The installation of the power cables L1 L2 must be done by qualified electricians Indoor unit Switch Source and comply with the regulations of the local power supply authorities and with the standards for electric appliances. • The environment conditions must be taken into consideration when the power cable connections are made (ambient temperature, exposure to heat, sunlight). • The specifications for the power cable refer to the minimum values of the metal core wires. Taking into consideration the voltage losses, the core wire of the power cable must be one size larger than the specifications. 21 3 L3 L4 21 3 L3 L4 L1 L2 Power 12 TROUBLE SHOOTING Cases requiring immediate contact with your dealer: • breaker or fuse breaks off often. • malfunction of TV, radio or similar devices. • switch does not result in sure performance • abnormal noise during operation. • if a faulty operation does not disappear after restart (after having waited for 3 minutes). Check the following before requesting after sales service from your dealer: The air conditioner does not operate at all. Poor cooling performance. The room temperature can not be controlled. Is the unit connected to a power supply? Has the time been set? Is there a power failure or a blown fuse? Is the temperature set at a suitable value? Are the filters clean? Open window(s), door(s), heat source(s) or many people in the room? Is direct sunlight entering the room? Is the temperature set outside the operating values? The unit can not be restarted just after it has been switched off. To protect the unit, restarting is only possible 3 minutes after a shut down. Air is not blown out in dehumidifying mode. The indoor fan is sometimes stopped to prevent vapor of dehumidified moisture. Mist is blown out during cool mode. This may sometimes occur when temperature and humidity in the room are very high and disappears with the lowering. Odor is coming out. Room air may contains smells, accumulated on the filter this can return to the room. Cracking sound is heard. This is caused by the refrigerant circulating inside the unit. Caused by the expansion or contraction of plastics (especially after a restart). Operation can not be restarted. The memory of the unit was cleared. Operating the remote control will restart the operation. Remote control signal not received. Direct sunlight or other strong light on the signal receiver on the interior unit. Moisture drips from the air outlet vanes. When the unit is in operation for a long period of time in high humidity, moisture may form on the vanes and drip down. Check the condensation outlet for proper drainage. 13 RATING LABELS Made in P.R.C. Cooling capacity Refrigerant Weight net ~44 - 50 dB(A) R410A IP 20 18 kg / 40 lb Dehumification up to 40 L/day 84 pts/day 1040 m3/h 36700 cu.ft/h 64-86 oF 18-30 oC Thermostatic range Protection class Airflow Noise level 13 BTU/h W SEER 5.1 kW 18000 BTU/h Carlstadt, New Yersey 07072 Caution: 1. Do not cover the air discharge openings. 2. Avoid risk of electric shock: disconnect before servicing. 3. Use only on a single outlet. 4. Wait 3 minutes after power has been switched off before restarting. 5. Moving parts inside: do not operate when the cover is removed. 6. A damaged power supply cord...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category