Login:
Votes - 3, Average rating: 3.7 ( )

User manual Amcor, model DWC-100C

Manafacture: Amcor
File size: 260.31 kb
File name:
Language of manual:
Free link for this manual available at the bottom of the page



manual abstract


of the right side. There are two kinds of method to install the drain cap. The rear side of the unit The first method is that the shape of hole like It is good for the household. The second method is that the shape of hole is like It is good for the shop. • DOOR VENT The door vent for the room air ventilation is lever type. If the door vent lever moves to the left, then close the vent and moves to the rght, then open the vent. Close Vent Open Drain Cap SEAL DRAIN Screw (Type D) Door Vent > 11 CARE AND MAINTENANCE CAUTION To avoid death or personal injury due to electrical shock, turn fan control OFF and unplug power cord before cleaning or performing maintenance. After cleaning or performing maintenance, reconnect power. • AIR FILTER Clean the air filter, which removes dust inside the room. It should be washed at least once every week during operation. 1. Remove the Air Filter from the front grill by pulling to right. 2. Clean Air Filter with a vacuum cleaner or lukewarm, soapy water. 3. Shake it when clean to remove moisture completely. Reinstall. ..; ..; ..; ..; ..; ..; ..; ..; ..; ..; NOTE A dirty Air Filter reduces air flow and the cooling capacity. Do not operate unit without Air Filter. • CLEANING THE AIR CONDITIONER 1. At least once a year, remove cabinet and thoroughly clean air conditioner. Have the unit inspected by an authorized service man to ensure unit is functioning properly. 2. Wash air conditioner with lukewarm, soapy water as needed. Rinse and dry thoroghly. 3. If using concentrated liquid detergent, dilute in warm water first. 4. Front grill may be wiped off with a cloth dampened in a mild detergent solution. 5. Cabinet may be washed with mild soap or detergent and lukewarm water, then polished with liquid wax for appliances. 6. Condenser and Evaporator coils should be cleaned at the beginning of each cooling season. Use a soft brush or vacuum cleaner to clean them, making sure that the Condenser and Evaporator coils are not damaged. 7. Do not use abrasive cleaners. These items scrach, crack and discolor surfaces. NOTE To assure continued peak efficiency, condenser coils (weather side of unit) should be checked periodically and cleaned if clogged with soot or dirt from the atmosphere. 12 ELECTRICAL REQUIREMENTS • ELECTRICAL GROUNDING INSTRUCTIONS This appliance is equipped with a three-prong(grounding) plug for protection against possible shock hazards. If a two-prong wall receptacle is encountered, the customer is required to contact a qualified electrician and have the two-prong wall receptacle replaced with a properly grounded three-prong wall receptacle in accordance with the National Electrical Code. WARNING : To avoid death, personal injury or properly damage due to electrical shock, this unit must be grounded. Do not under any circumstances cut or remove the round grounding prong from the plug. Do not use a two prong adapter. • USE OF EXTENSION CORD Because of potential safety haz...

Other models in this manual:
Air Conditioner & Split Systems - DWA-122CS (260.31 kb)
Air Conditioner & Split Systems - DWA-122CS (260.31 kb)
Air Conditioner & Split Systems - DWA-150C (260.31 kb)
Air Conditioner & Split Systems - DWC-100CS (260.31 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category