Login:
Votes - 5, Average rating: 4.2 ( )

User manual APC, model INROOM ACPSC3000

Manafacture: APC
File size: 1.1 mb
File name: MLAN-83FQDS_R1_EN.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Press down on the two tabs on the top of the grill to release the filter and grill from the cooling unit. - Carefully pull the air filter from the plastic hooks on the inside of the grill. 2. Clean the air filter. About every two to three weeks clean by gently vacuuming, wiping the filter with a dry cloth, or knocking the filter on a firm surface to dislodge dust. Do not use water to clean the filter. Replace the air filter See “Remove the air filter” (above) for instructions to properly remove the air filter. s 1. Install a new, clean filter by pressing the filter onto the hooks on the grill. 2. Attach the grill to the rear of the cooling unit. Set the bottom of the grill into the opening. Tabs on the grill bottom should enter the slots in the bottom of the opening. 3. Tip the top of the grill up and into the opening. The tabs on the top of the grill should snap into place. InRoom SC 50 Hz User Guide 19 Empty the condensate drain pan If the cooling unit is not routed to a permanent drain, allowing the drain pan to drain, the unit will shut down when the drain pan is full. See “Continuous draining” on page 12 for more information. A Caution: The cooling unit must be turned off and unplugged before draining. 1. With the power off and the unit unplugged, move the cooling unit to an appropriate place to drain the drain pan. Place the drainage port over a drain or use a container large enough to hold the contents of the drain pan. 2. Remove the drain plug and allow the pan to drain completely. 3. When the condensate has been drained, install the plug in the drain port. 4. Discard the contents of the drain pan. 5. Return the cooling unit to service. Storing while not in use Remove the rubber plug from the drain port and drain the water from the condensate drain pan. Allow the cooling unit to run with in the Fan mode for at least four hours in a low humidity environment to remove any moisture from the inside of the unit and prevent mold formation. Turn the cooling unit off. Unplug the cooling unit from the power source. Clean and reinstall the air filter. Remove the air exhaust hose. Wipe clean with a soft, dry cloth. Store in a safe place. Cover the air exhaust ports tightly. Remove the batteries from the remote control and store in a safe place. 20 InRoom SC 50 Hz User Guide Caster replacement A Warning: Tipping the cooling unit can cause damage. Raise the unit levelly at least 250 to 300 mm (10 to 12 in) to access the caster. Use the wrench that was shipped with the unit. See “Inventory” on page 6. Apply the wrench to the nut at the top of the caster. Turn the nut counterclockwise to loosen. When the old caster is removed, use the wrench to attach the new caster by turning the nut at the top of the caster clockwise. InRoom SC 50 Hz User Guide 21 I na3401a Troubleshooting Problem Unit does not run The unit stops running during operation. The unit runs but does not cool. The unit does not run and the Water Full indicator light is on. Error message E5 Error message H8 The unit is running in Dry mode but produces no cool air. The unit is running in Cool mode but produces no cool air. The displays shows the Timer hours isn’t operating. Solution If you are attempting to run the cooling unit from the remote control, check that the batteries in the remote control are good. Check that the unit is properly plugged into the power outlet. Check that the set temperature is lower than the room temperature. Check that the room is closed (no doors or windows open). Check that no heating appliance is working nearby. Check and clean the air filter if necessary. Check that the air inlet or outlet is not blocked. Check that the set temperature is not too high. Drain the condensate. See “Empty the condensate drain pan” on page 20 for more information. If the unit still will not work contact APC technical assistance. The power supply is unstable. Unplug the cooling unit for 10 minutes. If the error still exists, call maintenance or the power company to stabilize the utility power. The condensate drain pan is full. Empty the drain pan. Call APC customer support if the error message is still displayed after the drain pan is empty. The evaporator is defrosting. The unit will resume cooling when the defrosting operation is complete. The evaporator is defrosting. The unit will resume cooling when the defrosting operation is complete. The Timer is not set to ON. Cancel the operation and reset the Timer hours. 22 InRoom SC 50 Hz User Guide Spare Parts List Part Number 0J-0H-0307 0J-0H-0308 0J-870-16520 0J-876-0317 Description Ceiling exhaust kit Exhaust duct kit Swivel caster Air filter InRoom SC 50 Hz User Guide 23 Specifications Model APCSC3000 Net weight (Equipment only) - Kg (lb) 36 (79) Shipping weight - Kg (lb) 47 (102) Dimensions - H x D x W - mm (in) 876 x 370 x 455 (34 x 15 x 18 ) Voltage/Frequency/Phase 220/240 VAC - 50 Hz - 1 Ph Power inp...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category