desired operation. 3 33 ......0 Set the temperature. (16°C~30°C) . Supersonic air purifying device operates automatically once the unit is switched on. POWERFUL QUIET . and operations are available in all modes. OFF/ON . Press again to stop the operation. • Unit selects the operation mode according to temperature setting, outdoor and room temperature. • The power indicator blinks during operation. • Operation mode is reselected every 30 minutes. HEAT - Heating Operation • In heating mode, it takes a while for the unit to warm up. The power indicator blinks during this operation. COOL - Cooling Operation • Enjoy cool air at your desired temperature. DRY - Soft Dry Operation • Keeps your environment dehumidified by running a very gentle cooling operation. • During soft dry operation, the indoor fan operates at low fan speed. ¦Hint • A temperature setting 1°C higher in cooling operation or 2°C lower in heating operation than the desired temperature equates to a 10% power saving. ENGLISH Troubleshooting .Mist emerges from indoor unit. >Condensation effect due to cooling process. .Heating/Cooling operation does not work. >Ensure temperature is set correctly. >Make sure windows and doors are closed. > Make sure filters are cleaned and replaced. >Make sure inlet and outlet vents are cleared. . Water flowing sound during operations. > Cause by refrigerant flow inside the unit. .The power indicator blinks during the operation and the indoor fan is stopped. >The unit is in defrost mode, and the melted frost is drained from the outdoor unit. 5 FAN SPEED, AIR SWING ¦Operations Details FAN SPEED, AIR SWING ¦Operations Details FAN SPEED • There are 5 fan speeds, as well as automatic*. * For automatic fan speed, the speed of the indoor fan is automatically adjusted according to the operation. AIR SWING • Keeps the room ventilated. • There are 5 options for vertical/ horizontal airfl ow direction. • Do not adjust the vertical and horizontal louvers by hand. • If automatic vertical airfl ow direction has been set, the louvers swing up and down automatically. • For HEATING operation, the air blows horizontally for a while, then starts to blow downwards. • If automatic horizontal airflow direction has been set, the louvers swing left and right automatically. • For HEATING operation, the airflow louvers start to swing left/right after the temperature rises. TEMP AIR SWING FAN SPEED QUIET POWERFUL TIMER ON 1 2 3 OFF SET CANCEL MODE OFF/ON AC RC SET CLOCKCHECK RESET Select fan speed. AUTO HEAT FAN SPEED AIR SWING COOLDRY FAN SPEED AIR SWING Adjust the airflow direction louver. Troubleshooting .The room has a peculiar odour. >This may be a damp smell emitted by the wall, carpet, furniture or clothing. .Indoor fan stops occasionally during automatic fan speed setting. >This helps to remove the surrounding odours. .Indoor fan stops occasionally during heating operation. >To avoid unintended cooling effect. 6 POWERFUL, QUIET ¦Operation Details POWERFUL, QUIET ¦Operation Details QUIET Enables quiet operation. POWERFUL Enables powerful operation. AUTO HEAT FAN SPEED AIR SWING COOL DRY TEMP AIR SWING FAN SPEED QUIET POWERFUL TIMER ON 1 2 3 OFF SET CANCEL MODE OFF/ON AC RC SET CLOCKCHECK RESET POWERFUL QUIET . and operations could not be activated at the same time. POWERFUL QUIET . and operations could be cancelled by pressing the respective button again. POWERFUL • To reach the desired set temperature quickly. QUIET • To provide a quiet surrounding ¦Hint • To reduce power consumption during cooling operation, close the curtains to prevent the sunlight and heat from coming in. ENGLISH Troubleshooting .Noisy during operation. >The unit may have been installed at an incline, or the front panel is not closed properly. .Operation is delayed a few minutes after restart. >The delay is a protection to the unit’s compressor. .Outdoor unit emits water/steam. >Condensation or evaporation occurs on pipes. 7 ¦Operation Details • The timer allows you to turn the air conditioner on or off automatically. • The unit may start in preliminary operation before the actual set time when ON timer has been set. • The set timer repeats daily once set. • If there is a power failure, you can restore the previous setting (once power is resumed) by pressing the SET button. • If the timer is cancelled, press SET to restore the previous setting. ¦Hints • Press and hold the for approximately 5 seconds to set either 12-hour (am/pm) or 24-hour time indication. CLOCK • To dim the indicator display: TIMER ON 1 2 3 OFF SET CANCEL AC RC SET CLOCKCHECK RESETT C Press and hold for 5 seconds. To cancel, press the again for 5 seconds. • To switch the temperature setting to °C or °F, press and hold for approximately 10 seconds. TIMER 1 11 Select ON or OFF timer. AUTO HEAT FAN SPEED AIR SWING COOL DRY TEMP AIR SWING FAN SPEED QUIET POWERFUL TIMER ON 1 2 3 OFF SET CANCEL MODE OFF/ON AC RC CLOCKCHECK RESET C SET CH G SPEE CANCEL Cancel the selected timer. 2 22 2 Set the desired ti...
Other models in this manual:Air Conditioner & Split Systems - CS-E18FKR (1.32 mb)