Login:
Votes - 2, Average rating: 3.5 ( )

User manual Friedrich, model CP05 CP Line

Manafacture: Friedrich
File size: 2.16 mb
File name: 6281403e-b6e5-cb74-41f7-0e7ccadf2f5c.pdf
Language of manual:enesfr
Free link for this manual available at the bottom of the page



manual abstract


• TO CLEAN FILTER The air filter will become dirty as it removes dust from the inside air. It should be washed at least every 2 weeks. If the air filter remains full of dust, the air flow will decrease and the cooling capacity will be reduced, possibly damaging the unit. 1. Pull the inlet grille forward and pull out the air filter. (Fig. 1) 2. Wash the air filter in warm water. Be sure to completely dry the filter before placing it back into the unit. • CLEANING THE AIR CONDITIONER The front grille and inlet grille may be wiped with a cloth dampened in a mild detergent and lukewarm water solution. (Fig. 2) The cabinet may be washed with mild soap or detergent and lukewarm water. To ensure continued peak efficiency, the outdoor coil (condensor coil) should be checked periodically and cleaned if clogged with soot or dirt from the atmosphere. Consult a certified Friedrich service agent for more information. • HOW TO REMOVE THE FRONT GRILLE 1. Pull the inlet grille forward. 2. Remove the screw securing the Front Grille. (Fig. 3) 3. Push the grille up from the bottom and pull the top of the grille away from the case to lift the top tabs out of their slots. (Fig. 4) 4. Carefully position the grille, bottom first, and snap back into place. 5. Reposition the screw that secures the front grille and replace the knobs. Do not force open or open too far Fig. 1 Fig. 2 Fig. 3 Fig. 4 Control Tabs Filter Inlet grill Additional controls and important information. Air Direction • ADJUSTING THE AIR DIRECTION USING THE HORIZONTAL AIR-DEFLECTOR CONTROL Using the control tabs, the air flow can be directed to the left, right, straight ahead, or any combination of these directions. Care and Maintenance 8 1 8 5 32 9 4 10 7 6 Learning the key components will help you properly install the unit. Features 1. CABINET 2. HORIZONTAL AIR DEFLECTOR 3. COOL AIR DISCHARGE 4. FRONT GRILLE 5. INLET GRILLE 6. AIR FILTER 7. CONTROL BOARD 8. AIR INTAKE 9. UPPER GUIDE 10. REMOTE CONTROL Features and Installation Installation Instructions Window Requirements NOTE: All supporting parts should be firmly secured to wood, or metal. 1. This unit is designed for installation in standard double hung windows with actual opening widths of 22" to 36". The upper and lower sash must open sufficiently to allow a clear vertical opening of 14" from the bottom of the sash to the window sill. 2.If storm window presents interference, fasten a 2" wide wood strip (OUTER SILL) to the inner window sill across the full width of the sill. The wood strip should be thick enough to raise the height of the window sill so that the unit can be installed without interference by the storm window frame. See Fig. 5-2. Top of wood strip should be approximately 3/4" higher than the storm window frame (STORM WINDOW FRAME) or wood strip (OUTDOORS) to help condensation to drain properly to the outside. 3. Install a second wood strip (approximately 6" long by 11/2" wide and same thickness as first strip) in the center of the outer sill flush against the back off the inner sill. This will raise the L bracket as shown Fig. 5-2. 4. If the distance between STORM WINDOW FRAME and WOOD STRIP MOUNTED ON TOP OF INNER SILL is more than 1", two of wood strip are not necessary. L BRACKET INNER WOOD STRIP MOUNTED 1" MAX. SILL ON TOP OF INNER SILL STORM WINDOW INNER FRAME SILL WOOD STRIP FOR L BRACKET OUTER OUTER SILL SILL INDOORS OUTDOORS INDOORS OUTDOORS Fig. 5-1 Fig. 5-2 Installation 3/4" CLEARANCE HARDWARE TYPE A: 11EA (SHORT SCREW) TYPE B: 5EA (WOOD SCREW) TYPE C: 3EA (L BRACKET) 10mm16mm TYPE D: 1EA (SEAL STRIP) TYPE E: 1EA (SASH SEAL) TYPE F: 2EA (GUIDE PANEL) TYPE G: 1EA (SUPPORT BRACKET) (Adhesive backed) (Not adhesive backed) ENGLISH 9 A. BEFORE INSTALLATION 1. Insert the guide panels into the guides of the air conditioner. Fasten the curtains to the unit with screws (TYPE A) as shown Fig. 6. 2. Cut the adhesive-backed seal strip (TYPE D) to match the window width. Remove the backing from the seal strip and attach the seal strip to the underside of the bottom window. (Fig. 7) B. BEGIN INSTALLATION 1. LOCATING UNIT IN WINDOW Open the window and mark center line on the center of the inner sill, as shown in Fig. 8. 2. ATTACH L BRACKET a. Install the L brackets behind the inner window sill, with the short side of bracket as shown. Use the 2 screws (TYPE A) provided. b. The bracket helps to hold unit securely in place. Be sure to place bracket edge flush against back of inner sill. See Fig. 9. 3. INSTALL THE AIR CONDITIONER IN THE WINDOW a. Carefully lift the air conditioner and slide it into the open window. Make sure the bottom guide of the air conditioner drops into the notches of the L bracket. See Fig. 9. CAUTION During the following step, hold unit firmly until window sash is lowered to top channel behind side panel frames. Personal injury or property damage may result if unit falls from window. IMPORTANT : When the air conditioner drops into the L bracket, the air conditioner will be cente...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category