Adapter for temporary mounting of the exhaust hose (1) 4. Rawlplugs (4) 5. Screws (4) 6. Batteries (2) 7. Remote control (1) 8. Drainage hose (1) BEFORE USE Find a suitable location close to a mains outlet and a window or external door. Fit the exhaust hose to the air conditioner and the adjustable fittings to the window. Plug into a mains socket (220-240V ~50Hz) Ensure that the water tank is positioned correctly, or the airconditioner will not start. To start, press the “I/O” button (on/off) The dehumidifier function operates in the range 10 C° - 30 C° The cooling function operates in the range 17 C° - 30 C° If the cooler or dehumidifier has been switched off and then switched on again, it may take up to 3 minutes for the air conditioner to start up again. Cooler function: Press the “MODE” button repeatedly until the operating panel displays “COOL”. Press “arrow up” or “arrow down” to select the desired room temperature. Press “FAN” to obtain the desired blower speed. Dehumidifier function: Press the “MODE” button repeatedly until the operating panel displays “DRY”. The blower will run at a fixed speed on this function. Blower function: Press the “MODE” button repeatedly until the operating panel displays “FAN”. Press “FAN” to obtain the desired speed. The hose does not need to be fed out of the window. Heat function: Press the “MODE” button repeatedly until the “HEAT” indicator comes on. Set the desired temperature by pressing the up and down arrow buttons. Press “FAN SPEED” to set the blower speed. Timer function Setting the timer: Press the “TIMER ON” button while the air conditioner is switched off. Select the time you want it to start. “ON” will appear on the display. The time can be set between 0.00 and 23.50. Setting the timer to OFF: Press the “TIMER OFF” button while the air conditioner is switched on. Select the time when you want it to go off. “OFF” will appear on the display. The time can be set between 0.00 and 23.50. Drainage from the water tank: Connect the drainage hose prior to use (8 in illustration page 2). When the water reaches a pre-determined level, the drainage pump will be activated and will empty the water out via the drainage hose. The maximum height the pump can cope with is 3.5 metres. If the drainage hose is sealed or if the pump is not functioning, the water tank will fill up. The message "P1" will then appear on the device’s display panel and the device will stop automatically. Move the device carefully to a place with a sink. Empty the tank by removing the rubber stopper from the pipe (13 in illustration page 2). Once the tank is empty the device will function again. 19 Permanent drain: It is possible to have the water bypass the water tank and run straight to a drain. On the rear at the bottom (13 in illustration page 2) there is a pipe to which you can attach a hose to feed the water directly to the drain. Remember to remove the stopper from the pipe. We recommend emptying the tank completely in this way if it is to remain unused for a prolonged period. Installation: It is important that the device is positioned on a firm level surface well away from other objects. It must be at least 30 cm away from walls or other objects. The air outlet must not be covered. Fitting the flexible hose Movable: Attach one end of the hose to the device. Fit the other adapter to the other end, and feed it out into the open. Installation set for window An adapter for fitting in a window is enclosed. This can be positioned either vertically or horizontally. MAINTENANCE Always remove the plug from the socket before cleaning. Do not use cleaning agents containing solvents. Use a well-wrung damp cloth. Wipe off with a dry cloth. The air filter: The air filter should be cleaned at least once a fortnight. To remove the air filter, open the grille at the side, where the filter is located in a special holder. It can be cleaned by washing in hot water and a neutral cleaning agent. Allow it to dry before replacing it in the device, but avoid drying it in direct sunlight. Replace it in the filter holder and close the grille. TECHNICAL SPECIFICATIONS net. weight: 35.0 kg measurements (HxWxD): 84.0x48.0x40.0 cm power (max.): 1800 W cooling capacity (max.): 14000 Btu heating capacity (max.): 7000 Btu airflow (max.): 360m3/hr dehumidification capacity (max.): 2.8 L/hr cooling refrigerant: R407C Fixed installation: Attach one end of the hose to the device. Attach the other fitting to the other end, and feed it through the wall and out into the open. When the device is not in use the hole can be covered by a lid (enclosed). The flexible hose can stretch from 500 mm to 2000 mm. We recommend, however, keeping it as short as possible. Do not overstretch the flexible hose. 20 TROUBLE SHOOTING NB! THE GUARANTEE DOES NOT APPLY POSSIBLE CAUSES SUGGEST REMEDIES Water full indicator blinks, water tank is full. Room temperature is higher than the set temperature. (Heating mode) Room temperature is lower than the set te...