(anti-clockwise) Fix the adapter into the window slider kit, and then half open the window to meet the width of the window slider kit. The length of the window slider kit is adjustable. CONTROL PANEL 1. POWER button: press this button to turn on/off the unit. 2. MODE button: press this button to select Cooling, Automatic adjusting mode or Fan mode 3. SPEED button: press this button to select high, low fan speed 4. Timer: when stand-by time press this key to set automatic time on; when running time press this key to set automatic time off. 5. UP button: press this button to set the temperature higher when cooling; press this button to adjust time longer when timing; to exchange Fahrenheit and Celsius when press both UP and Down button 6. DOWN button: press this button to set the temperature lower or higher when cooling; press this button to adjust time shorter or longer when timing; to exchange Fahrenheit and Celsius when press both UP and Down button. OPERATION METHODS Cooling mode Default Cool mode after operating the machine or press Mode button to choose Cool mode, the Cool mode indicator will flash. ·Press UP or DOWN button to set room temperature between 17. to 30.. ·Press FAN SPEED button (or High/Low button) to select high, low fan speed. Fan mode ·Press Fan button to choose Fan mode, the Fan mode indicator will flash. ·Select the fan speed by press SPEED button or press High / Low button directly. ·The temperature can not be set. Automatic adjusting mode ·Press Mode button to choose the automatic mode. Automatic mode indicator will flash. After choosing the automatic mode, the running state will depend on room temperature. When room temperature is higher than 25., it will come into cool mode. On the contrary, it will be fan mode. You can select the fan speed mode and timer mode when it is under automatic adjusting mode. Sleep Mode (Optional Function) Press this button to activate or cancel sleep function in cooling mode The unit will run at the low fan speed as default with lower noise. The setting temperature will increase 1 degree per 2 hours running time, and it will not change after increasing 2 degrees Max cool Mode (Optional Function) Press this button to activate the Max cool mode. The unit runs cool but is not restricted by the temperature under the Max cool mode The unit is forced to be in high fan speed under the Max cool mode and the fan speed cant be set. Timer mode .When the appliance is switch off, press Timer button to set timer-on. ·Press Up or Down button to adjust time from 0 to 24 hours. The Timer on indicator will flash. When the appliance is running, press Timer button to set timer-off. Press Up or Down button to adjust time from 0 to 24 hours. The Time off indicator will flash. WATER DRAINAGE This product has a self-evaporative system. The condensing water will be recycled to cool the condenser. This can not only improve cooling efficiency, but also save energy for you. · If the inside water is full, the display panel will display “FL”, and the compressor will stop running. ·Please turn the machine off and move the machine to the place where can drain water, and then unplug the water-draining hole. After drainage, you can power it on and the machine will run again. MAINTENANCE Note: Turn off the unit and unplug it before any maintenance or repair begins to avoid electric shock. Cleaning ·Unplug the unit before any cleaning. ·Clean the housing with a soft moisture cloth. Do not use chemical solvent (such as benzene, alcohol, gasoline). The surface may be damaged or even the whole case may be deformed. ·Do not sprinkle water on the unit. Air filter ·Clean the air filter every 2 weeks. If the air filter is blocked with dust, the efficiency will reduce. ·Open the air filter cover upwards, and then take out the air filter. ·Wash the air filter by immersing it gently into warm (about 40.) water with a neutral detergent, rinse it and dry it thoroughly in a shaded place. End of season ·Please drain the water. ·Keep the unit running in Fan mode for two hours until the inside of the unit is dry. ·Turn off the unit and unplug it. ·Clean the air filter and after dry it thoroughly, reinstall it. ·Remove the exhaust pipes and keep them carefully. ·Wrap the unit with the plastic bag and keep it in a dry place. TROUBLE SHOOTING Before contacting professional service, check it first yourself referring to the followings: Problem Cause Solution The air conditioner does not function. No power supply. Connect to power supply outlet and switch on. “FL” flashes on the display screen Drain water. Timer-off is running. You can turn on the unit three minutes later. The air conditioner restart frequently In direct sunlight. Close curtains. Windows or doors open, many people or a heat source in the room. Close doors and windows, remove the heat source. Dirty filter. Clean or replace the filter(s). Air inlet or air outlet blocked. Remove the blockage. The unit is too noisy Unit stands uneven. Place on an e...