RETAINER FILTER 17CLIP CLIPVELCRO® ATTACHMENT POINTS FILTER DAILY INSPECTION & MAINTENANCE (cont.) Filter Cleaning Method . Remove dust from the element with a vacuum cleaner, or rinse in cold or lukewarm water. If the element is extremely dirty, wash with a neutral detergent. . After the element has been cleaned, rinse with clean running water, allow to dry, then FILTER reinstall. In-Season/Off-Season Inspection & Maintenance ¦ In-Season . Check the prongs and surface of the power cord plug for dust and/or dirt. If dust and/or dirt are present, wipe off with a clean, dry cloth. . Check the power cord, plug and prongs for damage or excess play. If any damage or excess play is found, contact your MovinCool reseller for repair. . Check the air filters and drain tank. . Clean the outside of the unit(s) with a damp cloth or mild nonabrasive cleaner. ¦ Off-Season . Operate the unit in Fan Only mode for 8 hours. Note: Operation is necessary to dry out the inside of the unit. . Disconnect the power cord from the AC outlet. . Check the prongs and surface of the power cord plug for dust and/or dirt. If dust and/or dirt are present, wipe off with a clean, dry cloth. . Check the power cord, plug and prongs for damage or excess play. If any damage or excess play is found, contact your MovinCool reseller for repair. . Clean the air filters. . Empty all water from the drain tank. 18 TROUBLESHOOTING Self-Diagnostic Codes Self-Diagnostic Codes will be displayed on the Control Board under the following conditions: Code Condition dF When the evaporator thermistor disengages the compressor. FL When the drain tank switch shuts off the unit (FULL TANK LED flashes). AS When unit disengages the compressor while the condensate pump is discharging water. HP When the high pressure switch disengages the compressor. LO Lowest temperature set point. HI Highest temperature set point. Check the following points before calling a qualified technician. TANK FULL SET POINT F C ROOM TEMP AM PM SET TEMP CLOCK/TIMER FAN ON/OFF COOL ON/OFF PROGRAM Office Pro SET START TIME END TIME SET CLOCK RUN HRS MIN SYMPTOM POSSIBLE CAUSE REMEDY Unit does not operate . Ground fault breaker tripped . Drain tank is full (FULL TANK LED will be flashing) Reset breaker Empty the drain tank Insufficient cooling . Dirty/blocked air filters . Air inlet/outlet blocked . Improper temperature setting Clean air filters Clear air inlet/outlet Set to desired position If symptoms persist after the above actions have been taken, turn the unit off, disconnect the power cord plug and contact your MovinCool reseller. 19 TECHNICAL SPECIFICATIONS ITEM/FEATURES Office Pro 12 Office Pro 24 Rating Conditions dry bulb 95. F (35. C) 95. F (35. C) wet bulb 83. F (28.2. C) 83. F (28.2. C) humidity (60%) (60%) Specifications power frequency 60Hz 60Hz line voltage single phase 115 V single phase 208/230V power consumption 1.23 Kw 2.7 Kw current consumption 11.3 Amps 13.1/11.8 Amps power factor 95% 99% starting current 32A 32.9A power wiring 14 (3-core) AWG 12 (3-core) AWG Cooling Unit cooling capability 2,950 Kcal/hr 11,700 BTU/hr 6,000 Kcal/hr 24,000 BTU/hr cooling system direct expansion direct expansion Blower type of fan air volume: Evaporator (High speed) Condenser (High speed) motor output (High) (Low) centrifugal fan 441 ft 3/min (745 m3/h) 823 ft 3/min (1391 m3/h) 0.14 Kw 0.08 Kw centrifugal fan 632 ft 3/min (1068 m3/h) 867 ft 3/min (1465 m3/h) 0.48 Kw 0.41 Kw Compressor type output refrigerant type refrigerant capacity rotary 0.8 Kw R-22 0.95 lbs (0.43 kg) rotary 1.4 Kw R-22 2.17 lbs (0.96 kg) Safety Devices compressor overload protector included included fan motor protector included included anti-freezing thermistor included included full drain tank switch included included automatic restart (power interruption) included included compressor time delay program included included Dimensions & Weight W x D x H (in) 21.2" x 27.4" x 44" 21.2" x 27.4" x 47.25" W x D x H (mm) 538 x 696 x 1118 538 x 696 x 1200 weight (lbs/kg) 165 / 75 210 / 95 Operating Conditions inlet air (relative humidity) 95. F (35. C), . 60% 65. F (18.3. C), . 50% 95. F (35. C), . 60% 65. F (18.3. C), . 50% Control Device temperature control programmable timer two speed fan included included included included included included 20 MANUAL de OPERACION OFFICE PRO 12 y OFFICE PRO 24 LA SOLUCION DE ENFRIAMIENTO LOCALIZADO PORTATIL 22 Tabla de Contenido PREFACIO ...................................................................................... 25 Definicion de terminos ............................................................ 25 PRECAUCIONES Y ADVERTENCIAS GENERALES ........................... 26 INVENTARIO ................................................................................... 27 INSTALACION ................................................................................ 28 Seleccion del sitio de instalacion...........................................28 Desplazamiento de la unidad .......................

Other models in this manual:
Air Conditioner & Split Systems - OFFICE PRO 24 (1.85 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category