|
Photos and specs Casio WK-500 |
manual abstract
Send This message is sent when the System Chorus Type setting is changed. Receive Receipt changes the System Chorus Type parameter. Rate Format Message Format: F0H 7FH 7FH 04H 05H 01H 01H 01H 01H 02H 01H vvH F7H vv: Value (Note1) Note 1: The setting value matches the value that is sent and received. Send This message is never sent. Receive Receipt changes the System Chorus Rate parameter. 18.1.6 GM System Message GM System On Format Message Format: F0H 7EH 7FH 09H 01H F7H Send This message is never sent. Receive Receipt puts the sound source into a GM sound source mode. GM System Off Format Message Format: F0H 7EH 7FH 09H 02H F7H Send This message is never sent. Receive Receipt changes the sound source setting to the Instrument presetting. GM2 System On Format Message Format: F0H 7EH 7FH 09H 03H F7H Send This message is never sent. Receive Though the Instrument does not support GM2, receipt of the GM2 System On message has the same result as receipt of the GM System On message. 22 18.1.7 GS Message Message Format: F0H 41H ddH 42H 12H 40H 00H 7FH 00H 41H F7H Note: dd (Device ID) is ignored. Send This message is never sent. Receive Receipt performs the same operation as when the GM System On message is received. 18.2 Instrument-Specific System Exclusive Message Format Message Format: F0H 44H 16H 01H....F7H This message can be used to send the Instrument memory status, for two-way transfer of special operation commands and user data, to perform sound source parameter operations, etc. For more information, see "Part IV Instrument-Specific System Exclusive Messages". 23 Part IV Instrument-Specific System Exclusive Messages 19 Format This section explains the format of the Instrument-specific System Exclusive Messages. See "Part V Parameter List" and "Part VI Parameter Set List" for information about how parameter sets actually are transferred. 19.1 Message Classifications Basically, the operation that corresponds to Instrument-specific system exclusive messages is parameter data transfer. The following operations can be performed from an external device using this parameter transfer message. • Modification of an individual Instrument parameter • Batch modification of a particular Instrument parameter set • Import of an individual Instrument parameter value • Batch import of a particular Instrument parameter set In addition to parameters being used as device setting values, some parameters act as commands when received by the Instrument and as device status information when sent from the Instrument. The following table shows the parameter category for each type of transfer. Function Section Parameter Category Description System System Commands to the Instrument, Instrument stats All All user data Song User Song Sequence Recorder Song Lesson Rec Recorder Song (Play-Along) Registration Registration Scale Memory User Scale Memory Rhythm User Rhythm Sound Generator Patch Sound source common settings (system effects, master settings, etc.) Instrument part settings (toneselection, mixer channel setting, tuning, etc.) Tone Sampled sound (melody/drum) selected by the user Drum Sampledsound (drum)referenced from "Tone"categoryparameters Instrument Individual instrument setting referenced from "Drum" category parameters Wave Parameter Sampled sound Wave setting Wave Data Waveform actual data referenced from "Wave Parameter" category parameters 24 19.2 Basic Message Structure Instrument-specific system exclusive message operation can be broadly divided between two methods: Individual Parameter Transfer (single parameter send/receive) and Bulk Parameter Set Transfer (batch parameter send/receive). Each method includes a number of different messages. The field in the SysEx message that specifies the message type is the action (act) field. The format of the "body" part of the message depends on the "act" value. The table below shows the body format for each action of Instrument-specific system exclusive messages. An actual message consists of the items indicated by "Y", from left to right. act SX MAN MOD dev act body (Depends onact) EOX cat mem pset blk pkt prm idx len data img sum NOP Y Y Y Y Y -----------Y IPR Y Y Y Y Y Y Y Y Y -Y Y Y ---Y IPS Y Y Y Y Y Y Y Y Y -Y Y Y Y --Y OBR Y Y Y Y Y Y Y Y --------Y OBS Y Y Y Y Y Y Y Y -Y --Y -Y Y Y HBR Y Y Y Y Y Y Y Y --------Y HBS Y Y Y Y Y Y Y Y -Y --Y -Y Y Y ACK Y Y Y Y Y Y Y Y --------Y BSY Y Y Y Y Y Y Y Y --------Y RJC Y Y Y Y Y Y Y Y --------Y EOD Y Y Y Y Y Y Y Y --------Y EOS Y Y Y Y Y Y Y Y --------Y ERR Y Y Y Y Y Y Y Y --------Y 19.3 Format of Each Field 19.3.1 SX : System Exclusive Message Status Format: 11110000B System Exclusive message Status = F0H 19.3.2 MAN : Manufacturer's ID Format: 01000100B Manufacturer's ID = 44H (CASIO) 19.3.3 MOD : Model ID Format: 00010101B (MSB) 00000001B (LSB) The Model ID of the series to which the Instrument belongs is shown by two consecutive bytes (MSB, LSB). (CTK-4000/CTK-5000/LK-205/LK-270/WK-200/WK-210/WK-500/CDP-200R Model ID MSB = 16H, ...
Other models in this manual:Computer Accessories - CDP-200R (295.86 kb)
Computer Accessories - LK-205 (295.86 kb)
Musical Instruments - WK-210 (5.29 mb)