User manual Cecilware, model BC302-IT

Manafacture: Cecilware
File size: 863.15 kb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


3 INSTALLATION AND OPERATING INSTRUCTIONS Warranty is void if the Brewer is connected to any Voltage other than the Voltage specified on the data label of the Brewer. UNPACKING AND INSPECTION Carefully unpack the Brewer by cutting the straps and lifting the carton off the Brewer. ASSEMBLY AND SET-UP The Brewer is shipped complete with: DESCRIPTION BC1-301-IT BC2-IT, 302-IT Adjustable legs 4 4 Carriers complete with Faucets and Covers 1 2 Funnels with sample Filter pack 1 2 Remove carriers from Brewer, one has the four (4) legs packed inside. Install legs by tilting Brewer on its back and screwing the legs into the threaded leg supports on bottom. WATER HOOK UP The National Sanitation Foundation (NSF) requires the following for NSF approved installation: 1. A quick disconnect water connection or enough extra coiled tubing (at least 2x the depth of the unit) so that the Brewer can be moved for cleaning underneath. 2. An approved flow-back prevention device such as a double check valve to be installed between Brewer and water supply. WATER CONNECTION The Brewer comes equipped with a . inch compression water inlet fitting located in the back. Use a . inch copper tubing to connect the Brewer to a cold water supply. Water pressure should be: 20 PSI min. to 90 PSI max. An external shut-off valve and a water filtering system with a charcoal filter are highly recommended. Turn water supply on and check for leaks at the water inlet connections, tighten compression fitting if necessary. ELECTRICAL CONNECTIONS A terminal block inside the base compartment is provided for electrical connections. Opening for field conduit connections are provided in the bottom and the back of the base. To access the Terminal Block, loosen the 2 screws on the side of the base cover. Disengage base cover from rear panel by lifting base cover up and lifting back towards rear panel. Power Cord CE202 - Optional RECOMMENDED WIRING SIZES Model No. Single (1) Phase BC301-IT 12 AWG BC2-IT, BC302-IT 10 AWG Note: 1. Neutral (N) and Ground Wires to be 14 AWG Minimum. 2. Field wiring must be suitable for 75. C. 3. Use Copper wire only for all power supply connections. 4 5 CANCEL POWER CANCEL microprocessor driven HOT WATER CAUTION PROGRAMMING INSTRUCTIONS The following is a Functional Description of the Single Station Brewer: Modes of Operation - Overview Initialization Mode – This mode is only active during the first few seconds after a “power-on” or system reset. The main function of this mode is to perform some special self-testing functions and configure the system using the previously saved operating parameters. Normal Mode – This mode becomes active immediately after Initializing Mode has completed its tasks. The main functions of this mode are to monitor and report system status and control brewing. Service Mode – This mode becomes active when the hidden keys under the Cecilware Logo (located on the upper-left-hand side of the keypad) and the first letter of the Model Name (located on the upper-righthand side of the keypad) are simultaneously depressed for more than two seconds while in Normal Mode. The main function of this mode is to allow access (for qualified personnel) to all system parameters that can be modified. Error Mode – This mode becomes active when the system detects a fatal error. The main function of this mode is to disable the unit and report the error to the operator. WARMER BUTTON POWER BUTTON CANCEL LAST OPERATION BREW BUTTONS LED LIGHTS TO ACCESS PROGRAMMING – Press Simultaneously Both Buttons TO SCROLL THRU PROGRAMMING FUNCTIONS – Press One Button TO CHANGE OR RESET PARAMETER VALUES LCD WINDOW MODES OF OPERATION – DESCRIPTIONS Initialization Mode: The following screen signifies the presence of this mode: CECILWARE &&&&& REV #.# Description – This mode is active only during the first few seconds after “power-on”. The purpose of the Initialization Screen is to identify the System Software Title (depicted by “&&&&&”) and Revision Number (depicted by “#.#”). Normal Mode: The following screen signifies the presence of Normal Mode: SSSSSS DDD K SSSSSS HH:MMP Description – Normal Mode is active immediately after Initialization Mode. The left half of the screen displays the present System State (depicted by “S”). Refer to the subsequent State Descriptions in this section for more information on System States. The right half of the screen displays the present day of the week (depicted by “D”), the present time (depicted by “HH”:”MMP”), and the current KeyLock Status (depicted by “K”). The day of the week is identified using familiar three letter abbreviations. The time is identified using hours and minutes along with a “AM/PM” indicator. If KeyLock is enabled the” KL” symbol will be present. Enabling KeyLock will prevent unauthorized users from operating the unit. Refer to the Service Mode Descriptions for more information on the KeyLock function. Filling State FILLING DDD K TANK HH:MMP Description – This screen is displayed during...

Other models in this manual:
Coffee Makers - BC2-IT (863.15 kb)
Coffee Makers - BC301-IT (863.15 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category