manual abstract


Wait 60 Seconds And Try Again. • For Spark At Electrode While Depressing Piezo NO 1/8" Gap To Pilot Hood Needed. • All Wiring Connections • Replace Piezo Ignitor • For Air In The Lines • Thermopile Needs A Min. 325m V. Adjust Pilot Flame Height. NO • All Wiring Connections • Replace Thermopile • Thermocouple Needs A Min. Of 14m V • Valve Is Turned On • Wall Switch Is Not Turned On. Watch For Grounded Wires! • Thermopile Needs A Min. 325m V. • Plugged Burner Orifice • Defective Valve. Turn to Pilot, Meter should rear greater than 100m V. If not, replace. YES Pilot Lights With Piezo Ignitor YES Pilot Stays Lit YES Pilot Lights Main Burner NO YES SYSTEM OK 30 10010618 31 RDV4136 Series Direct Vent Gas Fireplace 10010618 Conversions must be completed by qualified personnel Fuel Conversion Instructions To convert the RDV4136 units for use with a different gas follow these instructions. Before proceeding, turn control knob on valve to “OFF” and turn gas supply OFF. Turn OFF any electricity that may be going to the appliance. CAUTION: Logs may be HOT! Allow to cool before proceeding. 1. Remove valve access panel to gain access to valve. Remove window frame assembly. (See “Window Frame Assembly Removal”, Page 21, Fig. 38) 2. Remove logs if previously installed. SkyTech Valve 1. Remove rubber cap from valve. (Fig. 49) 2. Push pin in and turn so line on the end of the pin lines up with the appropriate gas. NAT for natural gas and LP for propane. 3. Replace cap. 4. Remove minimum rate screw and replace with new minimum rate screw supplied in kit. Refer to Table 1 on Page 32. Inlet PILOT Pilot Adj. Outlet MAIN FP1769 AF4000 valve face 2/07 .......... .............................................. ........ ...... ...... .... .... Main Connection Rubber Cap Gas Type Marker FP1769a CO137 Minimum Rate Screw Fig. 49 Remove rubber cap and adjust gas type marker. NOVA SIT820 Valve 1. Using the TORX T20 bit, remove and discard the three (3) pressure regulator mounting screws (A), pressure regulator tower (B) and the spring and diaphragm assembly (C). (Fig. 50) 2. Insure the rubber gasket (D) is properly positioned and install the new HI/LO pressure regulator assembly to the valve using the new screws (E) supplied with the kit. FC107.. SIT820.. valve conversion 10/03 A B C OFFPILOT ON FC107 Fig. 50 Remove mounting screws, pressure regulator tower and spring and diaphragm assembly. Tighten the screws securely. (Ref. torque = 25 in/lb) (Fig. 51) 3. Install the enclosed conversion label (F) to the valve body where it can easily be seen. (Fig. 51) Valve conversion is complete. D E F FC108.. SIT regulator conversion 10/03 OFF PILOT ON FC108 Fig. 51 Replace ignitor. Burner Orifice Conversion 1. Remove two (2) burner screws. (Fig. 52) 2. Remove burner housing assembly. (Fig. 52) 3. Remove burner orifice from manifold assembly using 7/16” wrench. (Fig. 52) 4. Install conversion orifices in place of orifices just removed. 5. Remove air shutters from burner pan by removing shutter retaining screw then air shutter. (Fig. 52) 6. Replace air shutter. Natural Gas: Hole on top of mixing tube set at 1/4 open. (Fig. 53) Propane Gas: Remove air shutter and discard. 7. Reinstall burner housing assembly and front burner tube. ............ .................... ........ Rear Log Support Pilot Location Remove Screws Air Shutter Orifice FP1850 Fig. 52 RDV4136 burner assembly. Pilot Hood Pilot Bracket CO133 CO148 air shutter conversion 3/08 djt Pilot Hood Pilot Bracket CO133 CO148 air shutter conversion 3/08 djt RDV4136 Series Direct Vent Gas Fireplace 1/2” Hole, 1/4 Open Air Shutter Air Shutter Screw CO148 Allen Wrench Index Tab Snap Ring CO134 Fig. 55 Remove pilot orifice. Table 1 Injector Orifice Size Matrix Conversion to LP Kit # CO13Model Burner Orifice Minimum Rate Screw Input (BTU/hr) 3 Description Part # Minimum Maximum 10010737 pilotRDV4136RN hood#53 (.0595”) 54833 n/a 19,500 24,000 3/07RDV4136IN #53 (.0595”) 54833 #54 20013177 19,500 24,000 Conversion to Natural Gas Kit # Model Burner Orifice Minimum Rate Screw Input (BTU/hr) Description Part # Minimum Maximum 10010736 RDV4136RP #40 (.098”) 55616 n/a 15,300 24,000 RDV4136IP #40 (.098”) 55616 #33 20014169 15,300 24,000 Fig. 53 Air shutter setting. Pilot Orifice Conversion 1. Remove pilot hood by lifting up. (Fig. 54) 2. Remove pilot orifice with Allen wrench. (Fig. 55) 3. Install conversion pilot orifice. Fig. 54 Remove pilot hood. 4. Reinstall pilot hood and be sure to align with index tab. 5. Turn the gas supply valve and gas valve on and test CO134 for leaks. Use a 50/50 solution of liquid soap and AF pilot orifice water to test for leaks at gas fittings and joints. Apply 3/07 water/soap solution with brush only -do not over apply. NEVER test with an open flame. 6. Follow procedure on rating plate to light the pilot. Check for leaks. 7. Turn main burner on and check for leaks. 8. Reinstall bracket rear log, front grate and logs. Refer to Page 22 for proper log placement. Fuel Conversion com...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category