Manafacture: Hampton Direct
File size: 3.97 mb
File name: 3418c9d1-3496-479e-a515-9fff7b22d6d7.pdf
|
manual abstract
Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's instructions. If you cannot reach your gas supplier, call the fi re department. This appliance may only be installed in an aftermarket permanently located, manufactured (USA only) or mobile home, where not prohibited by local codes. FOR YOUR SAFETY Do not store or use gasoline or other fl ammable vapours and liquids in the vicinity of this or any other appliance. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Tested by: Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please keep these instructions for future reference. 918-517 FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4 07/17/06 HAMPTON® Direct Vent Freestanding Gas Stove To the New Owner: Congratulations! You are the owner of a state-of-the-art Hampton® Gas Stove by FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. The H25 is a hand crafted appliance and has been designed to provide you with all the warmth and charm of a wood fireplace at the flick of a switch. The model H25 has been approved by Warnock Hersey for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Hampton® Stove. UNIT DIMENSIONS Hampton® H25-1 Direct Vent Freestanding Gas Stove TABLE OF CONTENTS Unit Dimensions ............................................................2 SAFETY LABEL Copy of Safety Label .....................................................4 REQUIREMENTS MA Code - CO Detector (for state of Massachusetts only) ..................................5 INSTALLATION Important Message ......................................................6 Specifi cations ................................................................6 Information for Mobile / Manufactured Homes After First Sale ..................................................6 General Safety Information ...........................................7 Installation Checklist ......................................................7 Clearances To Combustibles .........................................7 Locating Your Gas Stove ...............................................8 Manufactured Mobile Home Additional Requirements ..8 Combustion and Ventilation Air .....................................8 Optional Fan Installation ................................................8 Venting Introduction .....................................................10 Installation Precautions ...............................................10 Safety Precautions for the Installer .............................10 Vent Restrictor Position ...............................................10 Rotating 45o Elbow ......................................................10 Exterior Vent Terminal Locations .................................11 Rigid Pipe Venting Components List ...........................12 Rigid Pipe Venting Systems ........................................13 Venting Arrangements .................................................14 Vertical Termination with Co-linear Flex System .........17 DV Stove Horizontal Vent Kit .......................................18 Residential and Manufactured Homes / Mobile Homes ............................................................20 Minimum Horizontal Termination Installations .....20 Dura-Vent Termination Kit ............................................21 Horizontal Terminations ...............................................22 Vertical Terminations ...................................................23 Converting Class-A Metal Chimney or Masonry Chimney to Direct Vent System ...................25 Cathedral Ceilings .......................................................26 High Elevation .............................................................26 Gas Connection ...........................................................26 Aeration Adjustment ....................................................26 Gas Pipe .....................................................................27 Pressure Testing ..........................................................27 Conversion Kit #434-969 from NG to LP.....................28 Log Set Installation ......................................................31 Decorative Door Grill Installation .................................33 Wall Thermostat .........................................................33 Remote Control ..........................................................33 Wiring Diagrams ..........................................................34 Final Check .................
Other models in this manual:Fireplaces - H25-NG1 (3.97 mb)