Manafacture: Continental
File size: 2.3 mb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


side of the unit. The recommended maximum lead length depends on wire size: WIRE SIZE MAX. LENGTH 14gauge 100 feet 16gauge 60 feet 18gauge 40 feet Attach the two leads to terminals 1 and 3 located on the gas valve. FIGURE 4 1 2 3 FIGURE 5 Do not connect the gas valve to electricity (110 volts or 24 volts). W415-0120 / E / 01.11.05 UPPER LOUVRES Insert the back edge of the upper louvre into the upper louvre clips. FLUSH LOUVRE KIT, GI-1L FIGURE 8 UPPER LOUVRE LOUVRE CLIP SIDE VIEW LOWER LOUVRES Secure the lower louvre assembly to the insert, using the 4 screws supplied. UPPER LOUVRES Insert the back edge of the upper louvre into the upper louvre clips. FLUSH LOUVRE KIT, GI-1L FIGURE 8 UPPER LOUVRE LOUVRE CLIP SIDE VIEW LOWER LOUVRES Secure the lower louvre assembly to the insert, using the 4 screws supplied. To give your insert that authentic masonry fireplace look, Randomly place the embers beneath the front log, cover- FINISHING FIBRE FIREBRICK PANELS CHARCOAL EMBERS optional fibre firebrick panels are available at your Continental / Wolf Steel Ltd. dealer. Complete installation and maintenance instructions are included with the kit. LOG PLACEMENT PHAZERTM logs and charcoal embers, exclusive to Continental Fireplaces, provide a unique and realistic glowing effect that is different in every installation. Take the time to carefully position the charcoal embers for a maximum glowing effect. 1. Place the front log onto the main burner, pushing it as close as possible to the burner ports without blocking/covering them. The left and right spacing between the log ends and the burner ports should be equal. YOU MAY FIND IT EASIER TO PLACE SOME CHARCOAL EMBERS BENEATH THE FRONT LOG NOW. FIGURE 6 2. Place the back log onto the step located at the back of the combustion chamber. The notch situated at the lower right of the back log should be centered evenly above the pilot assembly. 3. While supporting the back log, to prevent it from falling forward, set the three smaller logs into the pockets and grooves of the front and back logs, respectively. Log colours may vary. During the initial use of the fireplace, the colours will become more uniform as colour pigments burn in during the heat activated curing process. POSITIONING THE LOGS IMPROPERLY WILL CAUSE FLAME IMPINGEMENT AND CARBONING. ing all of the burner area beneath the hollowed out section of the log. Place the remaining embers along the front. Keep ember dust away from burner ports to avoid plugging them. Fine dust found in bottom of bag not to be used. PHAZERTM logs and charcoal embers glow when exposed to direct flame. Use only certified PHAZERTM logs and charcoal embers available from your Continental / Wolf Steel Ltd. dealer. FIGURE 7 W415-0120 / E / 01.11.05 8 LOGO PLACEMENT LOGO13/8" FIGURE 9 11/8" Remove the backing of the logo supplied and place on the glass viewing area, as indicated. OPERATION / MAINTENANCE SPILL SWITCH VENTING ACTION CHECK This is a thermally activated switch, attached to the back of the unit and extending up into the dilution draft hood, which senses the change in temperature and shuts down the gas valve in the event of a severe downdraft of air or a blocked or disconnected vent. It acts as a safety shut-off to prevent a build up of carbon monoxide or an explosion of unburnt gases during start up. If the flue is blocked or has no "draw", the spill switch will automatically shut off the supply of gas within about 510 minutes. TAMPERING WITH THE SWITCH CAN RESULT IN CARBON MONOXIDE (CO) POISONING AND POSSIBLE FIGURE 10 DEATH. When lit for the first time, the fireplace will emit a slight odour for a few hours. This is a normal temporary condition caused by the curing of the logs and the "burn-in" of internal paints and lubricants used in the manufacturing process and will not occur again. Simply open a window to sufficiently ventilate the room. A CHECK FOR CORRECT VENTING ACTION MUST BE MADE BEFORE THE INSTALLED INSERT IS LEFT WITH THE CUSTOMER. Test after installing the unit into a vented non-combustible fireplace in the following manner: 1. Close all doors and windows in the room; start exhaust fans in the home; turn fireplace blower off. 2. Set controls to "high" and light the unit. 3. Wait 5 minutes. Light a match and hold it to the spill tube opening. 4. Venting action is satisfactory if smoke is drawn into the spill tube. Venting action is unsatisfactory if the flame and smoke are not drawn into the tube. 5. If venting action is unsatisfactory, turn the unit off, wait 10 minutes and try again. If the smoke or flame is still not drawn into the spill tube, turn the unit off and check for vent blockage or restriction. If necessary, consult with a qualified air quality specialist. After extended periods of non-operation such as following a vacation or a warm weather season, the fireplace may emit a slight odour for a few hours. This is caused by dust particles in the heat exchanger burning off. Open a window to sufficiently ventilat...

Other models in this manual:
Fireplaces - CBI 360-N (2.3 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category