Login:
Votes - 1, Average rating: 4 ( )

User manual Stovax, model 8574

Manafacture: Stovax
File size: 965.64 kb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


16 AR0369 6.13Ensure that the fibreglass seal on the back of the door is intact, locate the door on the four studs and slide back to the firebox. Secure in place using the four brass nuts and the tool supplied, do not over tighten the nuts, see diagram 17. Keep the tool with these instructions for future use. 17 AR0390 NEVER OPERATE THE STOVE WHEN THE DOOR IS REMOVED OR WHEN THE GLASS IS BROKEN. 15 INSTALLATION INSTRUCTIONS INSTALLATION Large Marlborough 6.14 Place the flame baffle onto the shelf at the rear of the tray and push up against the rear ledge, see diagram 18. 6.15 Locate the front coal moulding in front of the flame baffle ensuring that the end legs sit flat against the burner skin, see diagram 19. 18 AR0370 19 AR0371 6.16Place three large coals on the front coal so that they lean against the flame baffle and four large coals on the flame baffle so that they sit on the fingers, see diagram 20. 20 AR0372 6.17 Place three small coals at each end of the front coal so that they lean against the flame baffle and a further four large coals on the flame baffle, two at each end, see diagram 21. 21 AR0373 6.18 Place six small coals along the rear of the flame baffle, resting against the rear ledge, see diagram 22. 22 AR0374 NOTE: ENSURE THAT THE COALS ARE POSITIONED, AS DETAILED ABOVE. ONLY USE THE CORRECT AMOUNT OF COALS, AS SPECIFIED IN DIAGRAMS. 6.19 Ensure that the fibreglass seal on the back of the door is intact, locate the door on the four studs and slide back to the firebox. Secure in place using the four brass nuts and the tool supplied, do not over tighten the nuts, see diagram 23. Keep the tool with these instructions for future use. 23 AR0390 NEVER OPERATE THE STOVE WHEN THE DOOR IS REMOVED OR WHEN THE GLASS IS BROKEN. 16 INSTALLATION INSTRUCTIONS COMMISSIONING 1. COMMISSIONING 1.1 Close all openable doors and windows in the room. Ignite the stove and operate on maximum for 10 minutes. Remove the plastic sight plug from the right-hand side of the stove. Position a lighted smoke match just inside the draught diverter opening and check that all smoke is drawn into the opening. Watch through the viewing hole in the side of the casing. In restricted locations a mirror can be used. See diagram 1. If there is any doubt, run the stove for a further 10 minutes, and repeat the test. 1 1.2 If there are any extractor fans in adjacent rooms, the test must be repeated with the fans running on maximum and interconnecting doors open. IF SPILLAGE PERSISTS, DISCONNECT THE APPLIANCE AND SEEK EXPERT ADVICE. For future reference record the installation details on the Appliance Commissioning Checklist of these instructions. 17 SERVICING INSTRUCTIONS SERVICING / FAULT FINDING CHARTS 1. SERVICING REQUIREMENTS This appliance must be serviced at least once a year by a competent person. All tests must be serviced by best practice as described by the current CORGI recommendations. Refer to ADVICE ON HANDLING AND DISPOSAL OF FIRE CERAMICS In User Instructions section 5 1.1 Before any tests are undertaken on the appliance, conduct a gas soundness test for the property to ensure there are no gas leaks prior to starting work. 1.2 Before any tests are undertaken on the appliance it is also recommended to fully check the operation of the appliance. 1.3 Special checks 1.3.1 Clean any lint or fluff from the pilot - pay particular attention to the aeration hole in the side of the pilot 1.3.2 Clean away any fluff or lint from under the burner 1.3.3 Check the spark gap on the pilot is correct 1.4 Correct any faults found during the initial tests and then recommission the appliance conducting the usual safety checks. 1.5 Advise the customer of any remedial action taken. 1 IGNITION FUNCTIONAL CHECK 1PILOT WILL NOT LIGHTEnsure there is no debris around the pilot assembly,(e.g. soot, etc.) which could short the spark, clean the area.Operate the valve.Is there a spark?Consult Section 2on page 4 and retry.Check alignment of pilotburner head. Change theignition lead,see diagram 1, ServicingRequirements.Check isolation tap andgas meter, retry.Correct andretry.Purge the gas pipesand retry.SEE 'NO SPARK'CHART SYSTEM OKThere is a blockage in the system, check the mag seating, valve and pilot filter. Is the gas turned on to theappliance?Is the gas pressure correct?Has the system gotany air in it?Does the pilot light?Is the control beingoperated correctly?Will the pilot lightwith a match? No Yes NoYesNoYesYesNo NoYes NoNo YesYes 18 19 IGNITION FUNCTIONAL CHECK 2NO SPARKEnsure there is no debris around the pilot assembly,(e.g. coal, soot etc.) which could short the spark, clean the area.Consult Section 2on page 4, retry. Operate the valve to lightthe pilot, does the valve'click'?Is the pIlot burnerhorizontal?See diagram 1, ServicingRequirementsHas ignition leadbecome detached or isconnection poor?Remove the electrode leadfrom electrode with insulatedpliers. Hold the tip 4mm from thepilot pipework, is there a sparkwhen the valve ‘clicks’?Is the...

Other models in this manual:
Fireplaces - 8564 (965.64 kb)
Fireplaces - 8568 (965.64 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category