Login:
Votes - 2, Average rating: 4.5 ( )

User manual Stovax, model Clarendon & Ashdon 8544LUC-P8544LUC

Manafacture: Stovax
File size: 2.8 mb
File name:
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


This panel should locate on the screw holes of the burner skin. Ensure that both logs are horizontal to the burner ports. 5.5 Place log E across from the rear of log A to log C on the right hand side. Again, there are cut-outs for location. The front of the log should sit on the front ash panels and should fit tight to log C. See diagram 15. 5.6 Carefully insert the front coal retainer into the front panel of the firebox. Take care not the scrape/damage the logs. This coal retainer sits in two brackets. Ensure it is fully inserted, leaving approximately a 4 mm gap between the firebox ledge and the bottom of the coal retainer. AR1615 18 5.7 Ensure that the fibreglass seal on the back of the door is intact, locate the door on the four studs and slide back to the firebox. Secure in place using the four dome nuts and tool supplied, do not overtigthen the nuts, see diagram 17. NEVER OPERATE THE STOVE WHEN THE DOOR IS REMOVED. 6. LIGHTING 6.1 Full instructions are given in the User section under Lighting the Stove. INSTALLATION INSTRUCTIONS INSTALLATION 14 15 AR1616 16 AR1617 17 AR0540 1. COMMISSIONING 1.1 Having run the gas supply to the stove, PURGE THE SUPPLY PIPE, this is essential to expel any debris that may block the gas controls. Connect the gas supply to the 8mm compression elbow at the RH rear corner of the stove, see diagram 1. 1.2 Connect a suitable pressure gauge to the test point located on the inlet fitting, and turn the gas supply on. Light the appliance and check all gas joints for possible leaks. Turn the appliance to maximum and check that the supply pressure is as stated on the data badge. Turn the gas off and replace the test point screw, turn the gas on and check the test point for leaks. 1.3 Check that the installation instructions and any local regulations are complied with. Check that all seals are in good condition. Complete the Appliance Commissioning Checklist at the front of these Instructions. Explain the operation of the appliance to the end user. Hand the completed instructions to the User for safe keeping, as the information will be required when making any guarantee claims. 19 INSTALLATION INSTRUCTIONS COMMISSIONING AR0934 1 20 1. SERVICING REQUIREMENTS This appliance must be serviced at least once a year by a competent person. All tests must be serviced by best practice as described by the current CORGI recommendations. 1.1 Before any test are undertaken on the appliance, conduct a gas soundness test for the property to ensure that there are no gas leaks prior to starting work. 1.2 Before any tests are undertaken on the appliance it is also recommended to fully check the operation of the appliance 1.3 Special checks 1.3.1 Clean any lint or fluff from the pilot 1.3.2 Clean away any fluff or lint from under the burner 1.3.3 Check that the spark gap on the pilot is correct 1.3.4 Check all of the screws which secure the burner skins and tighten if they are loose. 1.4 Correct any faults found during the initial tests and then recommission the appliance conducting the usual safety checks. 1.5 Advise the customer of any remedial action taken. SERVICING INSTRUCTIONS SERVICING / FAULT FINDING CHARTS AR0620 1 PILOT WILL NOT LIGHT Ensure there is no debris around the pilot assembly, (e.g. soot, etc.) which could short the spark. Clean the area. Operate the valve. Is there a spark? NO YES YES NO NO YES NO YES YES NO NO NO YES YES Does the pilot light? Consult User Instructions and retry. Is the control being operated correctly? Check isolation tap and gas meter. Retry. Is the gas turned on to the appliance? Correct and retry. Is the gas pressure correct? Purge the gas pipes and retry. Has the system got any air in it? GO TO THE NEXT CHARGE IGNITION FUNCTIONAL CHECK 2 SYSTEM OK There is a block in the system. Check the inlet test point and the mag seating. Check alignment of pilot burner head. Change the ignition lead. See Replacing Parts, Section 2. Will the pilot light with a match? IGNITION FUNCTIONAL CHECK 1 21 SERVICING INSTRUCTIONS SERVICING / FAULT FINDING CHARTS NO SPARK IGNITION FUNCTIONAL CHECK 2 Ensure there is no debris around the pilot assembly, (e.g. coal, soot etc.) which could short the spark, clear the area. From Ignition Fault Finding Chart Part 1. Consult the Users Instructions, retry. Operate the valve to light the pilot, does the valve ‘click’? Is the valve being operated properly? Is the pilot burner horizontal? See diagram 1 on page 20. Reset the electrode gap, retry. Replace the pilot unit. Replace the electrode lead and retry. Remove the electrode lead from electrode with insulated pliers. Hold the tip 4mm from the pilot pipework, is there a spark when the valve ‘clicks’? Check the defective or damaged control knob spindle or cam operation. Check for correct location of piezo components. Correct and retry. Is the electrode wire detached from the piezo in the valve? Replace the combined lead, retry. Remove the electrode lead from the piezo. Operate the valve. Does a s...

Other models in this manual:
Fireplaces - 8545LUC, P8545LUC (2.8 mb)
Fireplaces - Clarendon & Ashdon 8547LUC-P8547LUC (2.8 mb)
Fireplaces - Clarendon & Ashdon ASHDON 8546LUC-P8546LUC (2.8 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category