4.3 Replace with a new ignition lead following the same route as the old one. Replace the valve cover and the pilot assembly. 4.4 Check operation of the new ignition lead. 5.1 The piezo assembly used on this appliance is not serviceable and is unlikely to fail. 5.2 If a new piezo is required it will be necessary to change the gas valve. Refer to Section 6. SERVICING INSTRUCTIONS REPLACING PARTS 4. IGNITION LEAD AND PIEZO 5. PIEZO 3. PILOT UNIT 5 6 7 8 AR0915 AR0916 22 6.1 Turn the gas supply off at the isolation device. 6.2 Disconnect the 2x8mm and 1x4mm gas pipe fittings at the back of the gas valve and also disconnect the thermocouple, see diagram 9. 6.3 Undo the single screw that secures the left-hand side of the control cover, see diagram 10. 6.4 To release the right-hand side of the control cover, insert the narrow blade screwdriver into the slot shown in diagram 11. Lever it gently and pull from the right-hand side at the same time. The cover will now come off. There is a small cylindrical metal spacer inside the cover. This must be kept and replaced on the fixing screw during re-assembly. 6.5 Disconnect the ignition lead from the gas valve. 6.6 Undo the two bolts securing the gas valve to the appliance and remove the valve. 6.7 Replace in reverse order. 6.8 Check all joints for gas leaks. Check operation of the thermocouple and ignition lead. 7.1 Turn the gas supply off at the isolation device. Undo the thermocouple connection from the back of the gas valve. Pull the sensor leads clear and remove the interrupter block. 7.2 Undo the magnetic valve-retaining nut from the back of the control valve. Gently tap out the magnetic valve and replace with a new unit. Replace the retaining nut and tighten. See diagram 12. 7.3 Reassemble the interrupter block and leads. Secure the thermocouple connection in the rear of the gas control. (Do not overtighten). Turn the gas supply on and check the entire pipework and valve joints for any leaks. SERVICING INSTRUCTIONS REPLACING PARTS 9 6. GAS VALVE 7. MAGNETIC SAFETY VALVE 10 11 AR0915 AR0916 12 23 8.1 Turn the gas supply off at the isolation device. Locate the main injector on the LH side of the airbox, undo the compression nut and pull the pipe clear of the injector body, see diagram 13A. 8.2 Rotate the injector until it is fully removed, and install the correct replacement injector. Reassemble and turn the gas supply on, check for leaks. . If the stove has been installed in a restrictive location, it may be necessary to remove the stove from its location. 9.1 Locate the sensor in the draught diverter opening, and gently pull the two wires off the terminals. Undo the two taptite screws and remove the sensor and the two plastic spacers. See diagram 14. 9.2 Refit a new sensor ensuring the spacers are located between the sensor and the bracket. Replace the two leads. 9.3 If it has been necessary to remove the stove, ensure that all disturbed gas joints are checked for gas soundness when reinstalled, and repeat the flue clearance test as detailed in the Commissioning Section. 10.1 Turn the gas supply off at the isolation device. 10.2 Locate the aeration plate on the underside of the airbox and remove the Nyloc nut, see diagram 15. 10.3 Remove the plate and replace with the correct size, ensure that the hole(s) in the plate align correctly with the holes in the underside of the airbox and replace the Nyloc nut. 11.1 In order to change between gas types, it will be necessary to change the following items. • Pilot Unit • Control Valve • Main Injector • Aeration Plate (if required) • Databadge The relevant parts can be ordered as a conventional kit from Gazco. Always quote the appliance type and serial number when ordering spare parts. ** NOTE: THE CONTROL VALVE IS FACTORY PRESET FOR CORRECT GAS TYPE AND MODEL. A NEW UNIT WILL NEED TO BE ORDERED WHEN CHANGING BETWEEN GAS TYPES. SERVICING INSTRUCTIONS REPLACING PARTS 8. MAIN INJECTOR 13 14 15 9. GAZCO FLUE SURE SYSTEM 10. PRIMARY AERATION PLATE 11. CHANGING BETWEEN GAS TYPES AR0389 AR0381 A AR0380 24 SERVICING INSTRUCTIONS REPLACING PARTS 12. CONTROL UPGRADE Components Small Medium Large Stove Stove Stove NG LPG NG LPG NG LPG Pilot Unit PI0036 PI0037 PI0036 PI0037 PI0036 PI0037 Injector IN0001 IN0003 IN0045 IN0006 IN0046 IN0044 Aeration Plate ME1094 ME1071 ME1096 ME0834 ME1071 ME10095 Gas Valve GC0088K* GC0088K* GC0088K* Flue Sensor EL0001 EL0001 EL0063 Sensor Lead X 2 EL0064 EL0064 EL0064 Interrupter GC0026 GC0026 GC0026 Mag Unit GC0092 GC0092 GC0092 Ignition Lead GC0090 GC0090 GC0090 Rear Panel CE0135 - - Flame Baffle CE0118 CE0120 CE0121 Front Coal CE0122 CE0124 CE0125/6 Coal Set CE0127 CE0136 CE0137 Burner Skin CEO114 CE0116 CE0117 Upgrade Kit Std 8455 Upgrade Kit Thermostatic 8456 *Set for Appliance 13. SHORT SPARES LIST See Installation, section 1. 25 SERVICE RECORDS 1ST SERVICE Date of Service:........................................................................... Next Service Due:...................................

Other models in this manual:
Fireplaces - 8517-P8517 (603.72 kb)
Fireplaces - Clarendon & Ashdon ASHDON 8513-P8513 (603.72 kb)
Fireplaces - Clarendon & Ashdon CLARENDON 8541-P8541 (603.72 kb)
Fireplaces - 8518-P8518 (603.72 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category