manual abstract


Install 1/2 inch certified gas pipe through opening. After gas pipe installation is complete, use insulation that was removed from gas line tube to repack space around the pipe. Material should be inserted from outside of the fireplace and packed tightly to totally seal between the pipe and tube. Note: Gas pipe should not come in contact with any wood structures until it has reached a point at least one (1) inch away from fireplace side. NOTE: When installing an ANSI Z21.11.2 ventless appliance, the finishing material used for the mantel must be rated at 250°F or greater. BTU input of a gas appliance installed in fireplace should be rated less than 100,000 BTU/Hr. Gas pipe installation is intended for connection to a decorative gas appliance only when (1.) incorporating an automatic shutoff device and (2.) complying with the Standard for Decorative Gas Appliances for Installation in Vented Fireplaces (ANSI Z21.60) or CSA draft requirements for Gas-Fired Log Lighters for Woodburning Fireplaces (Draft No. 4, August 1993). Decorative gas appliance should be installed in accordance with the National Fuel Gas Code, ANSI Z223.1/ NFPA 54 (latest edition). FP560 Fig. 27 Gas line access. 1" Min. 1/2" Hole in Outer Casing Fireplace Top View Supply Line Repack Insulation Ceramic Knock- out (both sides) Hole in Outer Casing Ceramic Knockout Gas Line Tube CAUTION: WHEN USING DECORATIVE GAS APPLIANCE, FLUE DAMPER MUST BE SET IN FULLY OPEN POSITION. IF YOU HAVE GLASS DOORS ON THE FIREPLACE, THEY MUST ALSO BE FULLY OPENED. WARNING: DO NOT OPERATE AN UNVENTED GAS LOG SET IN THIS FIREPLACE WITH THE CHIMNEY REMOVED. WARNING: WHEN INSTALLING AN UNVENTED GAS LOG SET, THE CFM CORPORATION MODEL AH3244BK OR AH3244PB 4" ADJUSTABLE HOOD MUST BE USED. Only unvented gas log sets which have been found to comply with the Standard for Unvented Room Heaters, ANSI Z21.11.2, are to be installed in this fireplace. 18 7412944 Majestic Fireplaces® BR/BC Series 1 2 3 4 5 6 a b c 7 8 9 10 11 12 d 13 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, with out notice. BR/BC SERIES For units: FA40R0, FA40R1, GA40R0, GA40R1 Item/Model Number BR/BC36 BR/BC42 1. Damper Blade Weld Assembly RP199 RP199 2. Damper Bracket 3030176 3030176 3. Screen Rod Assembly 3030126 3032112 4. Screen Assembly (two per fireplace) 7554338 7554340 5. Screen Pulls 7554239 7554239 6a. Firebrick - Hearth* 3030103 or 20007494 3032103 or 20007496 6b. Firebrick - Rear* 3030102 or 20007495 3032102 or 20007497 6c. Firebrick - Rt. Side* 3030160 or 20007492 3030160 or 20007492 6d. Firebrick - Lt. Side* 3030104 or 20007493 3030104 or 20007493 7. Top Brick Retainers (three per fireplace) 3030172 3030172 8. Cable Clips (four per fireplace) 7512135 7512135 9. Hearth Pan Cover (BC Only) 3031104 3031104 10. Outer Collar Assembly (SK8 Chimney) 3030143 3030143 11. Nailing Flange - Bag of 4 w/screws 2253160 2253160 12. Basket Grate 3030129 3030129 13. O.S.A. Assy. 20003076 20003076 * When ordering replacement firebrick, check the serial number and plant code of the fireplace, located on the UL label inside the firebox. Serial numbers/plant code with an 'H' require the firebrick listed first under the respective fireplace (white brick). Serial numbers/plant code with an 'X' require the firebrick listed second under the respective fireplace (grey brick). 7412944 19 Majestic Fireplaces® BR/BC Series Accessories The following accessories for this appliance are available from your local Majestic Fireplaces distributor. Should you need additional information beyond what your distributor can furnish, contact: CFM Corporation, 410 Admiral Blvd., Mississauga, Ontario, Canada L5T 2N6, Attn: Technical Services. CAUTION: This fireplace and chimney assembly is a highly engineered system, and, as such, must be operated only with CFM Corporation approved components. If you use an unapproved component to make any modifications, you may create a possible fire hazard and will void the CFM Corporation warranty. In addition, such action may void the coverage provided by the owner’s insurance. Accessory Description Model Number Glass Door — Standard Bi-Fold door set Brushed Brass finish 42GDKBB (BR/BC42) 36GDKBB (BR/BC36) Black finish 36GDKBK (BR/BC36) 42GDKBK (BR/BC42) Polished Brass finish 36GDKDP (BR/BC36) 42GDKDP (BR/BC42) Pewter finish 36GDKS (BR/BC36) 42GDKS (BR/BC42) Fan Kit Provides forced air flow FK12 Variable Speed Control Provides speed adjustment of fans SCVS Outside Air Termination Completes connection from air kit to out-of-doors AK-MST Hearth Extension Insulation Provides hearth extension floor protection EH2416 Grate for BR/BC36/42 Holds firewood in firebox RBBG36 Hearth Patch Compound Patch cracks in hearth HPC-1 Chimney System Adapter Collar Converts fireplace to a 3-wall chimney system TWABR Contact your Majestic Fireplaces distributor or dealer for finishing Marble and Mantels, available in a wide s...

Other models in this manual:
Fireplaces - BC36 (1.31 mb)
Fireplaces - BR36 (1.31 mb)
Fireplaces - BC42 (1.31 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category