Manafacture: Hearth and Home Technologies
File size: 2.82 mb
File name: 4066_300.pdf
|
manual abstract
Where the platform meets the wall, use a flashing detail similar to that required for attached decks. Chase platforms, including hearths should slope away from the structure at 1/8 in. to 1/4 in. per foot. The fireplace can be shimmed level. Outdoor Lifestyles by Hearth & Home Technologies Inc. • Carolina • 4066-300 • Rev. V • 4/12 Outdoor Lifestyles by Hearth & Home Technologies Inc. • Carolina • 4066-300 • Rev. V • 4/12 7 6 in. 6 in. 6 in. min. 36 in. min. cement board from the top of the firebox opening 36 in. min. noncombustible finishing material 82 in. (2083 mm) floor to ceiling 0 in. Combustible Object 36 in. (914 mm) Front Back Note: If this surface is inside the building’s warm air envelope... ...then this surface must be an exterior wall system. 45-1/2 in. (1156 mm) 57 in. (1448 mm) minimum 1 1/2 in. (38 mm) 56 in. (1422 mm) 79 1/4 in. (2013 mm) 17 in. (432 mm) 45-1/2 in. (1156 mm) 1 1/2 in. (38 mm) 1 1/2 in. (38 mm) Control Box Control Box 42 1/2 in. (1080 mm) minimum header height 42 1/2 in. (1080 mm) minimum header height 68 1/2 in. (1740 mm) minimum to top of cement board 44 in. (1118 mm) 17 in. (432 mm) Flashing Cement Board Control box MUST be relocated! Exterior Interior 11 1/2 in. (292 mm) minimum 8-1/4 in. (210 mm) 10-5/8 in. (270 mm) Framing 36 in. minimum (889 mm) from appliance front Side clearances can be zero at framing, up to 6 inches deep Side clearances can be zero at framing, up to 6 inches deep 6 in. 6 in. 36 in. minimum (889 mm) from appliance front Note: For actual appliance dimensions refer to Section 12. Figure 3.1 Appliance Locations and Framing Dimensions - CARODG36I, CARODG36IL NOTICE: Vinyl siding must not be placed between the fireplace opening and the ceiling/overhang. NOTICE: Flash the perimeter of the fi replace, corners and the fi replace face in a manner consistent with regional practices as required to prevent water penetration around the fi replace or manage water that may penetrate the fi replace. See Section 3.D. for more information regarding wall and enclosure construction. E. Clearances and Framing Dimensions CARODG36I, CARODG36IL Outdoor Lifestyles by Hearth & Home Technologies Inc. • Carolina • 4066-300 • Rev. V • 4/12 8 Framing 6 in. min. 82 in. (2.08 m) floor to ceiling 0 in. Combustible Object 36 in. (914 mm) Front Back Note: If this surface is inside the building’s warm air envelope... ...then this surface must be an exterior wall system. 51-1/2 in. (1.3 m) 63 in. (1.6 m) minimum 1-1/2 in. (38 mm) 59-5/8 in. (1.5 m) 82-1/4 in. (2.1 m) 17 in. (432 mm) 51-1/2 in. (1.3 m) 1-1/2 in. 1-1/2 in. (38 mm) (38 mm) Control Box Control Box 50-1/2 in. (1.28 m) minimum header height 50 in. (1.27 m) minimum header height 71-3/4 in. (1.82 m) minimum to top of cement board 50 in. (1.27 m) 17 in. (432 mm) Flashing Cement Board Control box MUST be relocated! Exterior Interior 11-1/2 in. (292 mm) minimum 36 in. minimum (889 mm) from appliance front Side clearances can be zero at framing, up to 6 inches deep 6 in. 6 in. Side clearances can be zero at framing, up to 6 inches deep 6 in. 6 in. 36 in. min. (914 mm) cement board from the top of the firebox opening 36 in. min. (914 mm) noncombustible finishing material 8-1/4 in. (210 mm) 10-5/8 in. (270 mm) 36 in. minimum (889 mm) from appliance front Note: For actual appliance dimensions refer to Section 12. Figure 3.2 Appliance Locations and Framing Dimensions - CARODG42I, CARODG42IL NOTICE: Vinyl siding must not be placed between the fireplace opening and the ceiling/overhang. NOTICE: Flash the perimeter of the fi replace, corners and the fi replace face in a manner consistent with regional practices as required to prevent water penetration around the fi replace or manage water that may penetrate the fi replace. See Section 3.D. for more information regarding wall and enclosure construction. E. Clearances and Framing Dimensions CARODG42I, CARODG42IL WARNING! Risk of Fire! Comply with all minimum clearances to combustibles as specified. Framing or finishing material closer than the minimums listed must be constructed entirely of non-combustible materials (i.e., steel studs, concrete board, etc). Fireplace StructureNoncombustible mat’lMantel 25 in. (635 mm) minimum 6 in. (151 mm) minimum - one side only. Alcove installations require 14 in. (356 mm) from each side of the firebox opening. 82 in. (2083 mm) minimum heightAdditional Structureor Sidewall Ceiling or Overhang 12 in. (305 mm) max. combustible mantel depth 49-1/2 in. (1257 mm) minimum 16 in. (406 mm) deep non-combustible hearth extension recommended when floor in front is combustible. Figure 3.3 Clearances Outdoor Lifestyles by Hearth & Home Technologies Inc. • Carolina • 4066-300 • Rev. V • 4/12 Outdoor Lifestyles by Hearth & Home Technologies Inc. • Carolina • 4066-300 • Rev. V • 4/12 10 4 Appliance Preparation A. Securing and Leveling Appliance Position, level, and secure the appliance. • Place the appliance into position on either a wood or noncombustible continuous ...
Other models in this manual:Fireplaces - CARDOG36IL (2.82 mb)
Fireplaces - CARDOG42I (2.82 mb)
Fireplaces - CARDOG42IL (2.82 mb)