Login:
Votes - 3, Average rating: 4.7 ( )

User manual Empire Comfort Systems, model VF24FP2-1

Manafacture: Empire Comfort Systems
File size: 2.96 mb
File name: 8d0fe4c3-6cfe-45b4-b122-81d6ba1c5160.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Breastboard will rest on fireplace top and in front of nailing flange. Attention: Placing the breastboard in front of nailing flange will secure the fireplace. 6. Placeleftmantelsideagainstbase.Insertdowelsinbreastboard into left mantel side. 7. Use four (4) pre-drilled screw holes on back of breastboard to secure breastboard to mantel sides with four (4) Phillips wood screws. 8. Place mantel top onto mantel. 9. Installation of fireplace into mantel is completed. Installation of Trim 1. Lower bottom louver. 2. Remove screen from fireplace. 3. Remove top louver from fireplace [two (2) Phillips screws]. 4. Attach right and lift trim to fireplace. Use two (2) Phillips screws for each side. 5. Attach trim top to fireplace with two (2) Phillips screws. 6. Reattach top louver to fireplace using two (2) Phillips screws. 7. Reattach screen to fireplace. Figure 9 8. Raise bottom louver. Figure 8 Page 10 20248-2-0806 BUILT-IN FIREPLACE INSTALLATION Rough Opening for Installing in Corner Built-In Fireplace Installation Built-in installation of this fireplace involves installing fireplace into a framed-in enclosure. This makes the front of fireplace flush with wall. If installing a mantel above the fireplace, you must follow the clearances shown in Figure 5, page 9. Follow the instructions below to install the fireplace in this manner. Frame in rough opening. Use dimensions shown in Figure 10 for a conventional rough opening. Use dimensions shown in Figure 11 for corner rough opening. Be sure to provide gas line for fireplace and electrical power for VFS-BK optional blower assembly. 1. Attach two (2) nailing flanges to firebox sides with two (2) 10 x 1/2" screws for each nailing flange. 2. Gas line connections must be made at this time. When facing the appliance the gas supply will enter on right-hand side. See "Gas Supply" Page 8. 3. Insert fireplace into enclosure. 4. Attach nailing flanges to framing with a screw or nail. 5. Finishedwallsurfacewillbeflushtotheleadingedgeoffireplace top and sides. 6. Installation of built-in fireplace is completed. Installation of Trim 1. Lower bottom louver. 2. Remove screen from fireplace. 3. Remove top louver from fireplace [two (2) Phillips screws]. 4. Attach right and lift trim to fireplace. Use two (2) Phillips screws for each side. 5. Attach trim top to fireplace with two (2) Phillips screws. 6. Reattach top louver to fireplace using two (2) Phillips screws. 7. Reattach screen to fireplace. 8. Raise bottom louver. Rough Opening for Installing in Wall Figure 11 Figure 12 (680mm) 4”(102mm) (286mm) Figure 10 20248-2-0806 Page 11 LOG PLACEMENT 1. Place rear (#1) log onto two (2) pins on rear log support. 2. Place left, front (#2) log onto two (2) left, front pins on burner pan. 3. Place right, front (#3) log onto two (2) right, front pins on burner pan. 4. Place branch (#4) log onto two (2) pins on rear (#1) log. Attention: Do not use Figure 13 to order logs. Refer to Page 19, Parts list and Page 20, Parts View to order logs. Refer to Figure 13 for the following warning. Warning: Failure to position the parts in accordance with this diagram or failure to use only parts specifically approved with this heater may result in property damage or personal injury. Figure 13 PLACEMENT OF GLOWING EMBERS (ROCK WOOL) Provided with the log set is a small bag of glowing embers (rock wool) to be placed between logs on the flat metal surface of the burner. Placement of the embers (rock wool) is very individual and light coverage of the areas indicated will provide your best effects. We recommend separation of the rock wool by hand and make your coverage as light and fluffy as possible. Place just enough embers (rock wool) on the burner to obtain the glow and a gold yellow flame. Do not place rock wool over large ports in rear portion of burner. A thin layer of rock wool should be placed under open space between the right and left middle logs. Rock wool should not be placed in the area of the pilot assembly. Replacement of loose material (glowing embers) must be purchased from Empire Comfort Systems, Inc. Application of excess loose material (glowing embers) may adversely affect performance of the heater. WARNING:All previously applied loose material must be removed prior to reapplication. Refer to Parts List, Page 19 to order loose material (rock wool). Replacement Loose Material (glowing embers) Part Number AVF24 15998 Platinum Bright Embers PE-20-1 Note:Asingle layer of embers is to be used when applying Platinum Bright Embers (alone or in combination with production embers) to the burner. OPERATION INSTRUCTIONS/FLAME APPEARANCE Flames from the pilot (rear right back side of the pan burner) as well as the main flame should be visually checked as the log set is installed. In normal operation at full rate after 10 to 15 minutes, the flame appearance should be sets of yellow flames. NOTE: all flames will be random by design, flame height will go up and down. Glowing embers (rock wool) can cover th...

Other models in this manual:
Fireplaces - VF24FP3-1 (2.96 mb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category