Login:
Votes - 1, Average rating: 3 ( )

User manual Burnham, model Indirect - Fired Water Heater AL SL

Manafacture: Burnham
File size: 1.77 mb
File name: 6efdd48c-b0b5-4ab8-a2d9-5f2e0fd1a8b2.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


When seeking information on the water heater, provide Model Number and Serial Number as shown on Rating Label. Model Number AL SL Serial Number Installation Date Heating Contractor Phone Number Address U.S. Boiler Company, Inc. Price - $5.00 00934-0 R - /07 GENERAL INFORMATION PLEASE READ INSTRUCTIONS CAREFULLY BEFORE INSTALLING WATER HEATER U.S Boiler Company, Inc. – Burnham Hydronics (herein called the Company) intends that this Alliance SL™ Indirect-Fired Water Heater be used as a separate zone to a heating system boiler. This appliance is designed to heat water by circulating water from the boiler through the internal coil in the tank. We specifically do not warrant this tank for high temperature applications such as wood stoves or steam producing systems. Such use of this product will automatically void the warranty. The design anticipates the proper installation and care in use of the product. There is risk of property damage and personal injury inherent in the use of any hot water system. The Company cannot supervise the installation and therefore makes it a specific condition of the warranty that the customer will supervise the installation and use of this product to be sure they are performed in accordance with safe guidelines and proper local or national codes. Generalized instructions and procedures cannot anticipate all situations. For this reason, only qualified installers should perform the installation. A qualified installer is a person who has licensed training and a working knowledge of the applicable codes, regulations, tools, equipment and methods necessary for safe installation of a boiler system and an indirect water heater. An installation checklist has been provided to help the customer ensure that all procedures for a safe installation have been followed. If questions regarding installation arise, check with your local plumbing and electrical inspectors for proper procedures and codes. Local codes take a precedent over instructions in this manual. SPECIFICATIONS & RATINGS Alliance SL Model Specifications Ratings Potable Volume (gal.) Height (in.) Diameter (in.) Weight (lbs.) 1st Hour (gal./hr) Cont. Draw (gal./hr) Standby Loss (°F/hr) AL 7SL 27 39.25 20.00 170 192 162 0.97 AL 35SL 35 39.25 22.75 198 200 162 0.72 AL 50SL 50 40.75 26.00 248 225 171 0.56 AL 70SL 70 45.75 28.00 300 294 217 0.45 AL 9SL 119 67.75 26.00 480 339 235 0.39 Domestic Water Inlet / Outlet = 3/4”M — T&P Valve = 3/4”F Boiler Water Supply / Return = 3/4”M — except AL 119SL = 1.0”M INDEX General Information ..................................................................................................................... 2 Specifications & Ratings .............................................................................................................. 2 Installation Guidelines ................................................................................................................. 4 Installation Checklist .................................................................................................................... 7 Service Information ...................................................................................................................... 8 TPI Control Diagrams (#1-3) ....................................................................................................... 10 Installation Piping Figures (#1 & 2) .............................................................................................. 12 Top Mount Coil Details & Tightening Sequence (Figure #3) ........................................................ 13 Circulator & Burner Control Wiring Diagrams .............................................................................. 14 Zone Valve Wiring Diagrams ....................................................................................................... 15 Switching Relay Wiring Diagrams ............................................................................................... 16 How to Obtain Service Assistance ............................................................................................... 18 Warranty ...................................................................................................................................... 29 Model and Serial Number Information ......................................................................................... 21 Optional Lifetime Warranty .......................................................................................................... Back Cover To fully understand the purchaser’s responsibilities for installing the water heater, please read the warranty. U.S. Boiler Company, Inc., – P.O. Box 3079 – Lancaster, PA 17604 INSTALLATION GUIDELINES A. INSPECTING AND PREPARING THE WATER HEATER q AL27SL thru AL70SL - Remove the cardboard box, which comes packaged with the heater. It should contain the following: TPI thermostat, T&P valve and a “Tee”, foamed lid and screws. q...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category