Login:
Votes - 3, Average rating: 3.7 ( )

User manual Napoleon Fireplaces, model GHC/GRD-5500

Manafacture: Napoleon Fireplaces
File size: 366.64 kb
File name: Lennox_Hearth_GHC-GRD_Installation_700027.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


Projection 8 in. (203 mm) Combustible Mantel Model No. A B GHC/GRD-5500 in. 11 65 1/2 mm 279 1664 GHC/GRD-6500 in. 10 67 1/2 mm 254 1715 Figure 34 Figure 35 GHC-5500 GRD-5500 Appliance Facing Flush with a Finished Wall Top ofFireplaceOpening Top ofFireplace Spacer Framing Combustible Finished Wall Combustible Mantel Noncombustible Covering Wall Combustible Finished Wall Combustible Mantel Noncombustible Covering Wall Louvers Framing Spacer Top ofFireplace Top ofFireplaceOpening Figure 36 Combustible Mantel Noncombustible Covering Wall NonCombustible Surround Louvers GHC-5500 Top ofFireplaceOpening Top ofFireplace Spacer FramingCombustible Finished Wall Materials Combustible Mantel Noncombustible Covering Wall NonCombustible Surround Framing Spacer Top ofFireplace Top ofFireplaceOpening GRD-5500 Combustible Finished Wall Materials NonCombustible Surround Materials Relative to Appliance Facing Figure 37 Combustible Mantel Louvers Combustible Finished Wall Materials Framing Spacer Top ofFireplace Top ofFireplaceOpening GHC-6500 Combustible Mantel Framing Spacer Top ofFireplace Top ofFireplaceOpening GRD-6500 Combustible Finished Wall Materials Appliance Facing Flush with a Finished Wall Figure 38 Combustible Mantel NonCombustible Surround Louvers Combustible Finished Wall Materials Framing Spacer Top ofFireplace Top ofFireplaceOpening GHC-6500 NonCombustible Surround Framing Spacer Top ofFireplace Top ofFireplaceOpening GRD-6500 Combustible Finished Wall Materials Combustible Mantel NonCombustible Surround Materials Relative to Appliance Facing NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. COLD CLIMATE INSULATION COLD CLIMATE INSULATION ments for venting are always maintained. To avoid air intrusion, surround material must be caulked where it meets the black metal facing of the appliance. Only use a noncombustible caulking material to seal this area. Do not place insulation materials within the 1" gas vent system clearance space. INSTALLATION ACCESSORIES The following accessory items are available for use in the installation of this appliance. Outside Air Kits Models FOAK and FOAK-LD Outside Air kits are available with duct (FOAK4) and without duct (FOAK-4LD) for use if outside combustion air is required or desired. If model FOAK-4LD is used it must be used in conjunction with locally purchased, non-combustible Class 1 or Class 0 flexible duct. Outside Combustion Air Kits (with duct) 81L87 FOAK-4 (without duct) 81L88 FOAK-4LD WARNING: THIS CONVERSION KIT SHALL BE INSTALLED BY A QUALIFIED SERVICE AGENCY IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS AND ALL APPLI- CABLE CODES AND REQUIREMENTS OF THE AUTHORIZED AGENCY HAVING JURISDICTION. IF THE INFORMATION IN THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE, EXPLOSION OR PRODUCTION OF CARBON MONOX- IDE MAY RESULT CAUSING PROPERTY DAMAGE, PER- SONAL INJURY OR LOSS OF LIFE. THE INSTALLATION IS NOT PROPER AND COMPLETE UNTIL THE OPERATION OF THE CONVERTED APPLIANCE IS CHECKED AS SPECIFIED IN THE OWNER INSTRUCTIONS SUPPLIED WITH THE KIT. AVERTISSEMENT: CET EQUIPEMENT DE CONVERSION SERA INSTALLE PAR UNE AGENCE QUALIFIEE DE SER- VICE CONFORMEMENT AUX INSTRUCTIONS DU FABRICANT ET TOUTES EXIGENCES ET CODES APPLICABLES DE L'AUTORISES AVOIR LA JURIDICTION. SI L'INFORMATION DANS CETTE INSTRUCTION N'EST PAS SUIVIE EXACTEMENT, UN FEU, EXPLOSION OU PRO- DUCTION DE PROTOXYDE DE CARBONE PEUT RESULTER LE DOMMAGES CAUSER DE PROPRIETE, PERTE OU BLESSURE PERSONNELLE DE VIE. L'AGENCE QUALIFIEE DE SERVICE EST ESPONSABLE DE L'INSTALLATION PROPRE DE CET EQUIPMENT. L'INSTALLATION N'EST PAS PROPRE ET COMPLETE JUSQU'A L'OPERATION DE L'APPAREIL CONVERTI EST CHEQUE SUIVANT LES CRITERES ETABLIS DANS LES INSTRUCTIONS DE PROPRIETAIRE PROVISIONNEES AVEC L'EQUIPEMENT. GAS CONVERSION KITS In Canada Kit part numbers are listed on the next page and the following steps detail the conversion THE CONVERSION SHALL BE CARRIED OUT procedure. IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING Note:These kits contain a main orifice which JURISDICTION AND IN ACCORDANCE WITH can be used for installation at elevations of THE REQUIREMENTS OF THE CAN1-B149.1 0-2000 Ft. (610 m.) For elevations greater AND .2 INSTALLATION CODE. than that, use the correct orifice as shown in table 2 on page 2. LA CONVERSION DEVRA ETRE EFFECTUEE CONFORMEMENT AUX RECOMMANDATIONS Step 1. Turn off the gas supply to the appliance. DES AUTORITES PROVINCIALES AYANT Open the doors or remove the enclosure panel. JURIDICTION ET CONFORMEMENT AUX EXIGENCES DU CODE D'INSTALLATION CAN1 Step 2. Carefully remove the two (5500 Mod B149.1 ET.2. els) or four (6500 Models) smaller logs on top. Gas conversion kits are available to adapt your Then remove the two (2) main logs. Exercise appliance from the use of one type of gas to the care as not to break the logs. use of another. These kits contain all the necessary components needed to complete the task including labeling that must be affixed to en sure safe operation. NOTE...

Other models in this manual:
Fireplaces - GHC/GRD-5500 (366.64 kb)
Fireplaces - GHC/GRD-5500 (366.64 kb)
Fireplaces - GHC/GRD-5500 (366.64 kb)
Fireplaces - GHC/GRD-5500 (366.64 kb)

Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category