Login:
Votes - 4, Average rating: 4.5 ( )

User manual Napoleon Fireplaces, model EPA 1450

Manafacture: Napoleon Fireplaces
File size: 1018.28 kb
File name: 168c6625-8eb4-e4a4-4595-17c1496d5025.pdf
Language of manual:en
Free link for this manual available at the bottom of the page



manual abstract


7’ between the stove base and the 2. Lift the stove up and away FIGURE 4A ceiling. from the pallet to clear the threaded studs sticking through the pallet. Place the stove on its BACK WALL BACK WALL SIDE WALL B A C 45° SIDE WALL back onto a protective surface such as a carpet or blanket to avoid scratches during leg installation. FIGURE 4B FIGURE 2B SINGLE WALL CHIMNEY CONNECTOR* 1100/1100L/1150 1400/1400L 1900 A 12” (305 mm) 12” (305 mm) 22” (560 mm) B 10” (254 mm) 12” (305 mm) 12” (305 mm) C 6” (152 mm) 6” (152 mm) 8” (205 mm) * CLEARANCES CAN BE REDUCED WITH SHIELDING ACCEPTABLE TO LOCAL AUTHORITIES. REDUCED INSTALLATION MUST COMPY WITH NFPA 211 or CAN/CSA-B365. DOUBLE WALL CHIMNEY CONNECTOR 1100/1100L 1400/1400L 1900 A 10” (254 mm) 10” (254 mm) 22” (560 mm) B 6” (152 mm) 6” (152 mm) 12” (305 mm) C 2” (50 mm) 4” (102 mm) 8” (205 mm) NOTE:CLEARANCES ARE UNABLE TO BE REDUCED FOR THE 1150 BY USING DOUBLE WALL PIPE. 3. Remove the four additional nuts from each of the four studs. CHIMNEY CONNECTION 4. Use four of the nuts and washers removed above to install the legs as illustrated in FIGURES 2a & 2b. 5. Lift the stove up and gently set down on all four legs. Do A 6” diameter single wall stove pipe, used to connect the stove to the chimney, must be installed with the crimped end toward the stove. This will ensure that the moisture which condenses from the burning wood will flow back into the fire chamber. Each joint in the stove pipe must be secured with at least three sheet metal screws. This room heater must be connected to: 1) A chimney complying with the requirements for Type HT chimneys in the Standard for Chimneys, Factory-Built, Resi not pivot unit up on its legs, as this could result in damage to the legs. ALCOVE INSTALLATION Model 1100 only may be installed, using a listed double wall connector, such as Security DL6 in Canada, the Simpson Duravent Plus DVL in the USA or an equivalent double wall connector, into an alcove having a depth of no more than 4 dential Type and Building Heating Appliance UL 103, or feet and a height of at least 7 feet. The minimum clearances 2) A code-approved masonry chimney with a fl ue liner. are as shown in FIGURE 3. Vent the stove into a masonry chimney or an approved, insulated solid-fuel stainless-steel chimney with as short and straight a length of six-inch (150mm) diameter smoke pipe 9" 6" 14" 23" 4 FOOT MAX as possible. Connection to a masonry chimney must be by a metal or masonry thimble cemented in place. An insulated stainless steel chimney must be supported at the ceiling or roof and its installation must comply with its manufacturer’s instructions. FIGURE 3 ALCOVE W415-0512 / D / 07.16.08 THE TOTAL HORIZONTAL VENT LENGTH SHOULD NOT EXCEED 40% OF THE CHIMNEY HEIGHT ABOVE THE STOVE. PEDESTAL MODELS OUTSIDE AIR If possible connect the air intake at the pedestal’s back or bottom to the outside with a 4 inch (100mm) diameter fresh air kit All horizontal smoke pipe must slope PEDESTAL BASE4.5"PEDESTAL BASE FLOOR AREA BELOW STOVE B" slightly upwards a minimum of 1/4” per available at your Napoleon/Wolf foot (6mm/0.3m) and all connections must Steel Ltd. dealer. Follow detailed be tight and secured by three sheet metal instructions under “Mobile Home screws equally spaced.Outside Air”. An uninsulated smoke pipe shall not pass A (in.) B(in.) 1100 8 5/8" 9 3/4" 1400 11 1/8" 9 3/4" 1900 14 7/8" 9 3/4" through an attic, roof space, closet or FIGURE 7 similar concealed space, or through a floor, ceiling, wall or partition, or any combustible WALL PASS-THROUGH construction. DO NOT USE ANY MAKESHIFT MATERIALS DURING INSTALLATION. 1. Move the stove into position with the flue centered, midpoint between two joists to prevent having to cut them. Use a plumb bob to line up the centre. 2. Cut and frame an opening in the roof to provide a 2” clearance between the outside of the chimney and any combustible material. DO NOT FILL THIS SPACE WITH ANY TYPE OF MATERIAL. If possible, design the installation so that the connector does not pass through a combustible wall. If during your installation you must pass through a combustible wall, check with your building inspector before you begin. Also check with the chimney connector manufacturer for any specific requirements. Consult with your dealer regarding special connection components This is the preferred method of passing a flue pipe through a combustible wall to a masonry chimney.FIGURE 8 Nail headers between the joist for extra support. Firestop available for use for wall pass-throughs. spacers must be placed on the bottom of each framed opening Use only parts that have been tested and listed for use in a in any floor or ceiling that the chimney passes through. wall pass-through. 3. Hold a plumb bob from the underside of the roof to determine where the opening in the roof should be. Cut and frame the roof opening to maintain proper 2” clearances. MOBILE HOME PEDESTAL MODEL 1100 IS APPROVED FOR INSTALLA A UNDERSIDE OF JOIST BILE HOME ...


Reviews



Your review
Your name:
Please, enter two numbers from picture:
capcha





Category